{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AXD50000199082","brand":"ABB","brandSlug":"abb","productSlug":"3AXD50000199082","canonicalUrl":"https://aoctrl.com/abb/3AXD50000199082","factsUrl":"https://aoctrl.com/api/mcp/products/3AXD50000199082","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACS480-04-046A-4 general purpose drive module, 3AXD50000199082, 22 kW / 45 A normal use, 380-480 V 3-phase, IP20, CAN, frame R4.","salesMarkdown":"The ABB 3AXD50000199082 is a low-voltage AC general purpose drive module, cataloged as the ACS480-04-046A-4. For applications with heavier duty cycles, the drive is rated 18.5 kW at 38.0 A (heavy-duty use), and for light-overload scenarios it holds 22.0 kW at 42.8 A. Under UL listing, normal-use output current is 40 A, heavy-duty 34.0 A, and light-overload 40.0 A. The module includes the control unit, so it arrives ready for integration. Communication is via CAN protocol; there are no industrial Ethernet interfaces onboard. Analog I/O is 2 inputs and 2 outputs; digital I/O counts 6 inputs and 3 outputs. ## Sizing and Mounting Notes Frame size R4, mounted as a module. Maximum ambient temperature is 50 °C; keep that in mind when planning panel ventilation. Standby loss is 38 W; power consumption at rated load is 582 W. Apparent power output is 31 kV·A. Efficiency class is IE2. The drive accepts line frequency from 47.5 to 63 Hz. A lithium coin cell (CR2032, 220 mAh, 3 V) is included for backup. Sound level is 69 dB(A) — noticeable in a quiet control room, but typical for a drive of this power class. WEEE category is 5 (small equipment, external dimension under 50 cm).","metaTitle":"3AXD50000199082 ABB ACS480-04-046A-4 Drive Module, 22 kW, 45","metaDescription":"ABB ACS480-04-046A-4 general purpose drive module, 22 kW normal use, 45 A output, 380-480 V 3-phase input, IP20, CAN, active production.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"SCIP":"195df5c0-4685-425b-8b31-e03d5656a0e8 Finland","Includes":"Control unit","Frame Size":"R4","Sound dB (A)":"69 dB(A)","Standby Loss":"38 W","Analog Inputs":"2","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Module","WEEE Category":"5. Small Equipment (No External Dimension More Than 50 cm)","Analog Outputs":"2","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Temperature Rating":"Maximum 50 °C","Enclosure Type NEMA":"Open Type","Input Voltage (Uin)":"380 ... 480 V","Degree of Protection":"IP20","Apparent Power Output":"31 kV·A","Communication Protocol":"CAN","Power Consumption (@Pcons)":"582 W","Multiple Battery Information":"Lithium Coin, CR2032, 220 mAh, 3 V, 1 pc, 3 g","Number of Digital In/Outputs":"6 / 3","Number of Hardware Interfaces":"Industrial Ethernet 0","Output Power, Normal Use (Pn)":"22 kW","Output Current, Normal Use (In)":"45 A","Output Power, Heavy-Duty Use (PhD)":"18.5 kW","Output Current, Heavy-Duty Use (IhD)":"38.0 A","Output Power, Light-Overload Use (PlD)":"22.0 kW","Certificates and Declarations/RoHS Date":"20230315","Certificates and Declarations/REACH Date":"20250905","Output Current, Light-Overload Use (IlD)":"42.8 A","Technical UL/Output Current, Normal Use (UL)":"40 A","Certificates and Declarations/RoHS Information":"Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019","Certificates and Declarations/REACH Information":"True - contains substances > 0.1 mass percentage","Technical UL/Output Current, Heavy-Duty Use (UL)":"34.0 A","Technical UL/Output Current, Light-Overload Use (UL)":"40.0 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3axd50000199082","alternativesUrl":"https://aoctrl.com/api/mcp/products/3AXD50000199082/alternatives.json"},"ai":{"faq":[{"question":"What is the SCIP number for this drive?","answer":"The SCIP number is 195df5c0-4685-425b-8b31-e03d5656a0e8 Finland."},{"question":"Does this drive include the control unit?","answer":"Yes, the listing includes the control unit — it ships ready for wiring and commissioning."},{"question":"What compliance documentation is available?","answer":"RoHS compliance per EU Directive 2011/65/EU and Amendment 2015/863 (date 20230315). REACH declaration confirms substances > 0.1 mass percentage (date 20250905). UL output current ratings are also listed."},{"question":"What are the key output ratings?","answer":"Normal use: 22 kW, 45 A (IEC) / 40 A (UL). Heavy-duty use: 18.5 kW, 38.0 A (IEC) / 34.0 A (UL). Light-overload use: 22.0 kW, 42.8 A (IEC) / 40.0 A (UL)."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AXD50000199082","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AXD50000199082 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}