{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AXD50000199563","brand":"ABB","brandSlug":"abb","productSlug":"3AXD50000199563","canonicalUrl":"https://aoctrl.com/abb/3AXD50000199563","factsUrl":"https://aoctrl.com/api/mcp/products/3AXD50000199563","rawCanonicalId":null},"summary":{"shortDescription":"ABB, ACS880-14 series, LV AC industrial regenerative single drive module, IEC: Pn 132 kW, 246 A, 400 V, Frame Size R11, IP20, Open Type.","salesMarkdown":"## Regenerative capability and efficiency The 3AXD50000199563: This is a regenerative drive — it returns braking energy to the line rather than dissipating it as heat. The efficiency class is IE2. Note that regenerative drives are exempt from EU ecodesign energy-efficiency data requirements under Regulation EU/2019/1781 §2.3.c, so no efficiency curve is provided here. Standby loss is 202 W; power consumption at rated load is 3383 W. Power factor is unity (1.0). ## Environmental limits and mounting Rated for a maximum ambient temperature of +55 °C, altitude up to 4000 m, and operating humidity of 5–95 % non-condensing. The module is IP20, open type — suitable for installation inside a clean panel or cabinet. Sound level is 75 dB(A). Mounting type is module; frame R11. Onboard I/O includes 2 analog inputs, 2 analog outputs, 6 digital inputs, and 2 digital outputs. Communication is via CAN; there are no industrial Ethernet interfaces on this module. The control unit is included. A lithium coin cell (CR2032, 220 mAh, 3 V, 2 pieces) backs the real-time clock.","metaTitle":"ABB 3AXD50000199563 ACS880-14 Regenerative Drive Module, 132","metaDescription":"ABB 3AXD50000199563 ACS880-14 regenerative single drive module, 132 kW normal use, 246 A, 400 V, IP20, frame R11. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"SCIP":"c2040ff1-7faf-493e-a1e8-90c1774c7ea5 Finland","Altitude":"4000 m","Includes":"Control unit","Frame Size":"R11","Power Factor":"1.0","Sound dB (A)":"75 dB(A)","Standby Loss":"202 W","Analog Inputs":"2","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Module","WEEE Category":"4. Large Equipment (Any External Dimension More Than 50 cm)","Analog Outputs":"2","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Temperature Rating":"Maximum +55 °C","Ecodesign Exemption":"Energy efficiency data is not provided for the drive. The regenerative drives are exempt from the EU ecodesign requirements (Regulation EU/2019/1781, §2.3.c).","Enclosure Type NEMA":"Open Type","Input Voltage (Uin)":"380 ... 415 V","Degree of Protection":"IP20","Apparent Power Output":"170 kV·A","Communication Protocol":"CAN","Power Consumption (@Pcons)":"3383 W","Operating Humidity (RHamβ)":"5 ... 95","Multiple Battery Information":"Lithium Coin, CR2032, 220 mAh, 3 V, 2 pcs, 6 g","Number of Digital In/Outputs":"6 / 2","Number of Hardware Interfaces":"Industrial Ethernet 0","Output Power, Normal Use (Pn)":"132 kW","Output Current, Normal Use (In)":"246 A","Output Power, Heavy-Duty Use (PhD)":"110 kW","Output Current, Heavy-Duty Use (IhD)":"206 A","Output Power, Light-Overload Use (PlD)":"132 kW","Certificates and Declarations/RoHS Date":"20240508","Certificates and Declarations/REACH Date":"20250905","Output Current, Light-Overload Use (IlD)":"234 A","Certificates and Declarations/RoHS Information":"Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019","Technical UL/Output Power, Heavy-Duty Use (UL)":"NA Hp","Certificates and Declarations/REACH Information":"True - contains substances > 0.1 mass percentage","Technical UL/Output Current, Heavy-Duty Use (UL)":"NA A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3axd50000199563","alternativesUrl":"https://aoctrl.com/api/mcp/products/3AXD50000199563/alternatives.json"},"ai":{"faq":[{"question":"What is the normal-use output rating of this drive module?","answer":"Normal-use output is 132 kW (Pn) at 246 A (In) from a 380–415 V three-phase supply. Heavy-duty rating is 110 kW (PhD) at 206 A (IhD)."},{"question":"What compliance documentation is available for 3AXD50000199563?","answer":"RoHS compliance dated 2024-05-08, REACH declaration dated 2025-09-05, SCIP number c2040ff1-7faf-493e-a1e8-90c1774c7ea5 (Finland), and WEEE category 4. UL heavy-duty output is not listed."},{"question":"What is the maximum ambient temperature for this drive?","answer":"Maximum ambient temperature is +55 °C. Altitude rating is 4000 m."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AXD50000199563","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AXD50000199563 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}