{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AXD50000200054","brand":"ABB","brandSlug":"abb","productSlug":"3AXD50000200054","canonicalUrl":"https://aoctrl.com/abb/3AXD50000200054","factsUrl":"https://aoctrl.com/api/mcp/products/3AXD50000200054","rawCanonicalId":null},"summary":{"shortDescription":"ABB drive control unit, frame size R11, 355 kW normal use, 503 A output, IP20, 380-500 VAC 3-phase.","salesMarkdown":"## What this unit is and what it drives The ABB 3AXD50000200054 is a drive control unit in frame size R11, rated for 355 kW normal-use output (503 A) and 315 kW heavy-duty output (460 A) on a 380–500 VAC three-phase supply. The heavy-duty current rating of 460 A is the figure that governs continuous motor load in a constant-torque application — the normal-use 503 A assumes a lighter, variable-torque profile. Light-overload use (492 A) sits between the two, matching the normal-use power of 355 kW but at a slightly lower current. Open-type enclosure with IP20 protection — suitable for a clean, dry cabinet, not for washdown or dust-laden areas. The unit is rated for operation up to +55 °C ambient and 4000 m altitude without derating; above that, expect to reduce current or forced-cool. Humidity range 5–95% RH non-condensing. Sound pressure at 75 dB(A) under load — noticeable in a small panel room, so factor in ear protection if the drive runs near operators. ## Power quality and efficiency Rated power factor of 1.0 and standby loss of 247 W. The IE2 efficiency level is standard for this class; note the ecodesign exemption — low-harmonic drives are not required to report energy-efficiency data under EU 2019/1781 §2.3.d, so the absence of an IE class on the nameplate is expected, not a defect. Apparent power output is 436 kV·A, which gives a rough sizing guide for the upstream transformer and cabling. ## I/O and communications Built-in analog I/O: 2 inputs, 2 outputs. Digital I/O: 6 inputs, 2 outputs. Communication is CAN-based — no onboard Industrial Ethernet (0 hardware interfaces listed). If the application requires PROFINET, EtherNet/IP, or Modbus TCP, an optional fieldbus adapter module must be added. The control unit includes a lithium coin cell (CR2032, 220 mAh) for real-time clock backup; two cells are fitted, total 6 g.","metaTitle":"ABB 3AXD50000200054 R11 Drive Control Unit, 355 kW","metaDescription":"ABB 3AXD50000200054 R11 drive control unit. 355 kW normal use, 315 kW heavy-duty, 503 A output. IP20, 380-500 VAC input. Current production. RFQ for lead time.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Inverter / VFD"],"specifications":{"SCIP":"c44fe560-7ab6-4f91-9cdb-6ff4cf7e4d81 Finland","Altitude":"4000 m","Includes":"Control unit","Frame Size":"R11","Power Factor":"1.0","Sound dB (A)":"75 dB(A)","Standby Loss":"247 W","Analog Inputs":"2","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Module","WEEE Category":"4. Large Equipment (Any External Dimension More Than 50 cm)","Analog Outputs":"2","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Temperature Rating":"Maximum +55 °C","Ecodesign Exemption":"Energy efficiency data is not provided for the drive. The low-harmonic drives are exempt from the EU ecodesign requirements (Regulation EU/2019/1781, §2.3.d).","Enclosure Type NEMA":"Open Type","Input Voltage (Uin)":"380 ... 500 V","Degree of Protection":"IP20","Apparent Power Output":"436 kV·A","Communication Protocol":"CAN","Power Consumption (@Pcons)":"7533 W","Operating Humidity (RHamβ)":"5 ... 95","Multiple Battery Information":"Lithium Coin, CR2032, 220 mAh, 3 V, 2 pcs, 6 g","Number of Digital In/Outputs":"6 / 2","Number of Hardware Interfaces":"Industrial Ethernet 0","Output Power, Normal Use (Pn)":"355 kW","Output Current, Normal Use (In)":"503 A","Output Power, Heavy-Duty Use (PhD)":"315 kW","Output Current, Heavy-Duty Use (IhD)":"460 A","Output Power, Light-Overload Use (PlD)":"355 kW","Certificates and Declarations/RoHS Date":"20240508","Certificates and Declarations/REACH Date":"20250905","Output Current, Light-Overload Use (IlD)":"492 A","Certificates and Declarations/RoHS Information":"Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019","Technical UL/Output Power, Heavy-Duty Use (UL)":"400 Hp","Certificates and Declarations/REACH Information":"True - contains substances > 0.1 mass percentage","Technical UL/Output Current, Heavy-Duty Use (UL)":"483 A","Technical UL/Output Power, Light-Overload Use (UL)":"400 Hp","Technical UL/Output Current, Light-Overload Use (UL)":"492 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3axd50000200054","alternativesUrl":"https://aoctrl.com/api/mcp/products/3AXD50000200054/alternatives.json"},"ai":{"faq":[{"question":"What compliance documentation is available for this unit?","answer":"RoHS compliance per EU 2011/65/EU (date 20240508), REACH declaration (date 20250905, contains substances >0.1%), UL listing for heavy-duty and light-overload use, and SCIP number c44fe560-7ab6-4f91-9cdb-6ff4cf7e4d81 (Finland) for WEEE reporting."},{"question":"What are the key electrical ratings for this drive control unit?","answer":"Normal-use output: 355 kW / 503 A. Heavy-duty output: 315 kW / 460 A. Light-overload output: 355 kW / 492 A. Input voltage: 380–500 VAC three-phase, 47.5–63 Hz. Apparent power: 436 kV·A."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AXD50000200054","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AXD50000200054 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}