{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AXD50000222629","brand":"ABB","brandSlug":"abb","productSlug":"3AXD50000222629","canonicalUrl":"https://aoctrl.com/abb/3AXD50000222629","factsUrl":"https://aoctrl.com/api/mcp/products/3AXD50000222629","rawCanonicalId":null},"summary":{"shortDescription":"ABB 3AXD50000222629, R11 frame drive, 160 kW normal duty, 302 A output, IP20, 380-500 VAC, includes control unit.","salesMarkdown":"The ABB 3AXD50000222629 is a current-production R11 frame drive delivering 160 kW normal-duty output (302 A) and 132 kW heavy-duty output (260 A) from a 380–500 VAC, 47.5–63 Hz three-phase supply. The heavy-duty current is the number that governs motor overload capability in a continuous process; the 302 A normal-duty figure applies when the load profile stays below 110 % overload for short intervals. The drive includes a control unit, so no separate controller purchase is needed for basic operation. Enclosure is IP20 (open-type NEMA) — sized for cabinet mounting where the environment stays clean and dry. The R11 frame is a large module; plan panel depth and gland-plate access accordingly. The drive is exempt from EU ecodesign energy-efficiency requirements under Regulation EU/2019/1781 §2.3.d, as a low-harmonic drive. Efficiency class is listed as IE2. UL technical ratings are provided: heavy-duty use at 200 Hp / 260 A, light-overload use at 250 Hp / 302 A. ## Environmental and mounting considerations Rated for operation at altitudes up to 4000 m — useful for installations in high-altitude plants or mine sites where derating curves typically start above 1000 m. Ambient temperature maximum is +55 °C, with humidity range 5–95 % non-condensing. Standby loss is 243 W; the drive dissipates 4773 W at full load, so forced-air cooling and cabinet sizing must account for that heat rejection. Sound pressure level is 75 dB(A) — noticeable in a control room; locate the cabinet away from operator stations if noise is a concern. The drive includes two analog inputs and two analog outputs, plus 6 digital inputs and 2 digital outputs. Communication is via CAN; no onboard Industrial Ethernet. The module contains two CR2032 lithium coin cells (220 mAh each) for memory backup.","metaTitle":"ABB 3AXD50000222629 R11 Drive, 160 kW Normal Duty, 302 A","metaDescription":"ABB 3AXD50000222629 R11 frame drive, 160 kW normal duty, 302 A output, IP20, 380-500 VAC, current production. Sourced to order. Request RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Inverter / VFD"],"specifications":{"Altitude":"4000 m","Includes":"Control unit","Frame Size":"R11","Power Factor":"1.0","Sound dB (A)":"75 dB(A)","Standby Loss":"243 W","Analog Inputs":"2","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Module","WEEE Category":"4. Large Equipment (Any External Dimension More Than 50 cm)","Analog Outputs":"2","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Temperature Rating":"Maximum +55 °C","Ecodesign Exemption":"Energy efficiency data is not provided for the drive. The low-harmonic drives are exempt from the EU ecodesign requirements (Regulation EU/2019/1781, §2.3.d).","Enclosure Type NEMA":"Open Type","Input Voltage (Uin)":"380 ... 500 V","Degree of Protection":"IP20","Apparent Power Output":"262 kV·A","Communication Protocol":"CAN","Power Consumption (@Pcons)":"4773 W","Operating Humidity (RHamβ)":"5 ... 95","Multiple Battery Information":"Lithium Coin, CR2032, 220 mAh, 3 V, 2 pcs, 6 g","Number of Digital In/Outputs":"6 / 2","Number of Hardware Interfaces":"Industrial Ethernet 0","Output Power, Normal Use (Pn)":"160 kW","Output Current, Normal Use (In)":"302 A","Output Power, Heavy-Duty Use (PhD)":"132 kW","Output Current, Heavy-Duty Use (IhD)":"260 A","Output Power, Light-Overload Use (PlD)":"160 kW","Certificates and Declarations/RoHS Date":"20240508","Certificates and Declarations/REACH Date":"20250320","Output Current, Light-Overload Use (IlD)":"302 A","Certificates and Declarations/RoHS Information":"Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019","Technical UL/Output Power, Heavy-Duty Use (UL)":"200 Hp","Certificates and Declarations/REACH Information":"True - contains substances > 0.1 mass percentage","Technical UL/Output Current, Heavy-Duty Use (UL)":"260 A","Technical UL/Output Power, Light-Overload Use (UL)":"250 Hp","Technical UL/Output Current, Light-Overload Use (UL)":"302 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3axd50000222629","alternativesUrl":"https://aoctrl.com/api/mcp/products/3AXD50000222629/alternatives.json"},"ai":{"faq":[{"question":"What are the key power ratings for this drive?","answer":"Normal-duty output is 160 kW at 302 A; heavy-duty output is 132 kW at 260 A. Light-overload rating matches the normal-duty current of 302 A."},{"question":"Does this drive include a control unit?","answer":"Yes, the listing specifies that the drive includes a control unit, so no separate controller purchase is required for basic operation."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AXD50000222629","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AXD50000222629 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}