{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AXD50000268856","brand":"ABB","brandSlug":"abb","productSlug":"3AXD50000268856","canonicalUrl":"https://aoctrl.com/abb/3AXD50000268856","factsUrl":"https://aoctrl.com/api/mcp/products/3AXD50000268856","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACQ580-01, LV AC wall-mounted drive, 3-phase 208-240 V, Frame R7, IP55/NEMA 12, 75 Hp light-overload / 60 Hp heavy-duty (UL), 84 kV·A apparent power.","salesMarkdown":"The ABB 3AXD50000268856 is a wall-mounted LV AC drive for water and wastewater duty. It runs on 208-240 V three-phase, frame size R7, and carries a NEMA 12 / IP55 enclosure. UL light-overload rating lands at 75 Hp / 211 A; heavy-duty use is 60 Hp / 60 A. That 211 A figure on light-overload tells you the drive can handle a sustained pump or fan curve without derating — typical for variable-torque loads in water treatment. Standby loss is 22 W, which matters for panel thermal planning — not a lot of heat when the motor is stopped, but enough to keep the enclosure venting honest. Efficiency is IE2, and the drive accepts 50/60 Hz line frequency. The 211 A light-overload rating is the one that drives sizing for most water/wastewater applications — pumps and fans rarely need the full heavy-duty headroom. If your motor plate calls for 60 A or less, you've got margin either way. Apparent power output is 84 kV·A. Input voltage is 208-240 V, so this is a low-voltage drive. Frame R7 means a larger wall-mount unit; plan panel real estate accordingly. Wall-mounting, NEMA 12 / IP55. That's the key spec for placement: it's rated for indoor use where dust, falling dirt, and dripping non-corrosive liquids are present. No need for a separate cabinet in a typical treatment plant environment. Maximum ambient temperature is 40 °C — keep the cooling air path clear.","metaTitle":"ABB 3AXD50000268856 ACQ580-01 Drive, 75 Hp, 211 A, IP55","metaDescription":"ABB ACQ580-01 LV AC wall-mounted drive, 75 Hp light-overload (211 A), 60 Hp heavy-duty (60 A), 208-240 V, IP55, NEMA 12, active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 240V"],"specifications":{"Frame Size":"R7","Standby Loss":"22 W","Frequency (f)":"50/60 Hz","Mounting Type":"Wall-mounting","WEEE Category":"4. Large Equipment (Any External Dimension More Than 50 cm)","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Temperature Rating":"Maximum 40 °C","Enclosure Type NEMA":"Type12","Input Voltage (Uin)":"208 ... 240 V","Degree of Protection":"IP55","Apparent Power Output":"84 kV·A","Technical UL/Output Power, Heavy-Duty Use (UL)":"60 Hp","Technical UL/Output Current, Heavy-Duty Use (UL)":"60 A","Technical UL/Output Power, Light-Overload Use (UL)":"75 Hp","Technical UL/Output Current, Light-Overload Use (UL)":"211 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3axd50000268856","alternativesUrl":"https://aoctrl.com/api/mcp/products/3AXD50000268856/alternatives.json"},"ai":{"faq":[{"question":"What enclosure protection does this drive have?","answer":"NEMA 12 and IP55. Suitable for wall-mounting in dusty or damp indoor environments without an additional cabinet."},{"question":"What is the frame size and input voltage?","answer":"Frame size R7. Input voltage is 208-240 V AC, three-phase, 50/60 Hz."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AXD50000268856","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AXD50000268856 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}