{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AXD50000270972","brand":"ABB","brandSlug":"abb","productSlug":"3AXD50000270972","canonicalUrl":"https://aoctrl.com/abb/3AXD50000270972","factsUrl":"https://aoctrl.com/api/mcp/products/3AXD50000270972","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACS580-01-046A-2 general purpose drive, 3-phase 208-240 V input, 46.2 A light-overload / 30.8 A heavy-duty, 15 Hp / 10 Hp, IP21, NEMA 1, wall-mount, frame R3.","salesMarkdown":"The ABB 3AXD50000270972 is an ACS580-01-046A-2 general-purpose wall-mounted drive, built for 3-phase 208–240 V input. Light-overload rating hits 46.2 A and 15 Hp; heavy-duty use drops to 30.8 A and 10 Hp. Frame size R3, IP21 enclosure, NEMA Type 1 — sized for a standard wall-mount install. Light-overload (LO) current of 46.2 A is the number to use for variable-torque loads like fans and pumps — that's the 15 Hp line. Heavy-duty (HD) at 30.8 A covers constant-torque applications like conveyors or extruders. Apparent power output is 18 kV·A. Standby loss sits at 15 W, worth factoring into panel heat calculations. Ambient temperature limit is 40 °C maximum; above that, derate.","metaTitle":"ABB 3AXD50000270972 ACS580-01-046A-2 Drive, 46.2 A, 240 V","metaDescription":"ABB ACS580-01-046A-2 general purpose drive, 3-phase 208-240 V, 46.2 A LO, 30.8 A HD, 15 Hp LO, 10 Hp HD, IP21, NEMA 1, wall-mount, active production.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 240V"],"specifications":{"Frame Size":"R3","Standby Loss":"15 W","Frequency (f)":"50/60 Hz","Mounting Type":"Wall-mounting","WEEE Category":"5. Small Equipment (No External Dimension More Than 50 cm)","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Temperature Rating":"Maximum 40 °C","Enclosure Type NEMA":"Type1","Input Voltage (Uin)":"208 ... 240 V","Degree of Protection":"IP21","Apparent Power Output":"18 kV·A","Technical UL/Output Power, Heavy-Duty Use (UL)":"10 Hp","Technical UL/Output Current, Heavy-Duty Use (UL)":"30.8 A","Technical UL/Output Power, Light-Overload Use (UL)":"15 Hp","Technical UL/Output Current, Light-Overload Use (UL)":"46.2 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3axd50000270972","alternativesUrl":"https://aoctrl.com/api/mcp/products/3AXD50000270972/alternatives.json"},"ai":{"faq":[{"question":"What is the frame size of this drive?","answer":"Frame size R3."},{"question":"What is the standby loss of this drive?","answer":"Standby loss is 15 W."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AXD50000270972","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AXD50000270972 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}