{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AXD50000285044","brand":"ABB","brandSlug":"abb","productSlug":"3AXD50000285044","canonicalUrl":"https://aoctrl.com/abb/3AXD50000285044","factsUrl":"https://aoctrl.com/api/mcp/products/3AXD50000285044","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACH580-01 HVAC drive, 3AXD50000285044, Frame R7, 3-phase 500-600 V, 100 Hp light-overload, 99 A, IP21, NEMA 1, wall-mounted.","salesMarkdown":"The ABB 3AXD50000285044 is an ACH580-01 wall-mounted HVAC drive in Frame R7, rated for 3-phase 500-600 V input and delivering 100 Hp light-overload output at 99 A (UL, 575 V). That 99 A figure is the light-overload duty rating — the one that governs continuous fan and pump loads in HVAC applications, not the higher burst rating for short-duration peak demand. The IP21 enclosure and NEMA Type 1 rating mean it's suitable for clean indoor environments — no washdown, no dust. Wall-mounting keeps floor space clear, but the R7 frame is substantial; plan for adequate wall anchoring and clearance for the heatsink airflow. Runs on 50/60 Hz line frequency, so it's at home on either 50 Hz or 60 Hz grids without derating — common for HVAC drives that ship globally. This is a current-production drive, sourced through standard ABB distribution channels.","metaTitle":"ABB 3AXD50000285044 ACH580-01 HVAC Drive, 100 Hp, 99 A, 575","metaDescription":"ABB 3AXD50000285044 ACH580-01 wall-mounted HVAC drive, 3-phase 500-600 V, 100 Hp light-overload, 99 A, IP21, NEMA 1, Frame R7. Active production, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 600V"],"specifications":{"Frame Size":"R7","Frequency (f)":"50/60 Hz","Mounting Type":"Wall-mounted","WEEE Category":"4. Large Equipment (Any External Dimension More Than 50 cm)","lifecycle_stage":"current","Number of Phases":"3-phase","Enclosure Type NEMA":"Type1","Input Voltage (Uin)":"500 ... 600 V","Degree of Protection":"IP21","Technical UL/Output Power, Light-Overload Use (UL)":"100 Hp","Technical UL/Output Current, Light-Overload Use (UL)":"99 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3axd50000285044","alternativesUrl":"https://aoctrl.com/api/mcp/products/3AXD50000285044/alternatives.json"},"ai":{"faq":[{"question":"What is the frame size of this drive?","answer":"Frame R7. That's a physical size class that determines mounting hole pattern, heatsink dimensions, and wiring access — verify panel clearance against the ACH580-01 R7 outline drawing before committing the layout."},{"question":"What input voltage and frequency does it accept?","answer":"3-phase 500-600 V at 50/60 Hz. The wide voltage range covers 480 V, 575 V, and 600 V nominal grids without a transformer tap change."},{"question":"What is the light-overload output rating?","answer":"100 Hp at 99 A (UL, 575 V). This is the continuous rating for variable-torque loads like fans and pumps — the rating that matters for sizing the drive to the motor nameplate."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AXD50000285044","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AXD50000285044 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}