{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AXD50000417414","brand":"ABB","brandSlug":"abb","productSlug":"3AXD50000417414","canonicalUrl":"https://aoctrl.com/abb/3AXD50000417414","factsUrl":"https://aoctrl.com/api/mcp/products/3AXD50000417414","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACS580-01 series, LV AC general purpose wall-mounted drive, 11 kW, 46.7 A, 230 V, IP21, frame size R3, 3-phase input 200-240 V, CAN protocol.","salesMarkdown":"## Duty ratings that matter for motor matching The 3AXD50000417414: Normal-duty output is 11 kW at 46.7 A — that's your everyday pump/fan curve. Light-overload use sits at 11.0 kW and 46.2 A, nearly identical to normal duty but with a different overload profile; check the drive's parameter set if you're pushing the overload cycle. Frame size R3, wall-mounted, IP21 enclosure with NEMA Type 1 equivalency. Ambient temp max 40 °C, altitude 1000 m — derate above that. Standby loss is 15 W, so the panel's thermal budget can treat it as a minor heat source. Sound level 76 dB(A) — noticeable in a quiet control room, fine on the plant floor. Two analog inputs, two analog outputs, six digital inputs, three digital outputs. Communication is CAN — no onboard Industrial Ethernet, so if the line talks PROFINET or EtherNet/IP, you'll need an add-on module. The control unit is included; no separate order needed.","metaTitle":"ABB 3AXD50000417414 ACS580-01 Drive, 11 kW, 46.7 A, 230 V","metaDescription":"ABB ACS580-01 general purpose drive, 11 kW, 46.7 A, 230 V, IP21, frame R3, active production. SCIP f1c9bd3a-ea8b-410d-bd78-7d4098ee31cf Finland. RoHS/REACH compliant. Order to spec","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 240V"],"specifications":{"SCIP":"f1c9bd3a-ea8b-410d-bd78-7d4098ee31cf Finland","Altitude":"1000 m","Includes":"Control unit","Frame Size":"R3","Sound dB (A)":"76 dB(A)","Standby Loss":"15 W","Analog Inputs":"2","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Wall-mounted","WEEE Category":"5. Small Equipment (No External Dimension More Than 50 cm)","Analog Outputs":"2","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Temperature Rating":"Maximum 40 °C","Enclosure Type NEMA":"Type1","Input Voltage (Uin)":"200 ... 240 V","Degree of Protection":"IP21","Apparent Power Output":"19 kV·A","Communication Protocol":"CAN","Power Consumption (@Pcons)":"533 W","Operating Humidity (RHamβ)":"5 ... 95","Multiple Battery Information":"Lithium Coin, CR2032, 220 mAh, 3 V, 1 pc, 3 g","Number of Digital In/Outputs":"6 / 3","Number of Hardware Interfaces":"Industrial Ethernet 0","Output Power, Normal Use (Pn)":"11 kW","Output Current, Normal Use (In)":"46.7 A","Output Power, Heavy-Duty Use (PhD)":"7.5 kW","Output Current, Heavy-Duty Use (IhD)":"30.8 A","Output Power, Light-Overload Use (PlD)":"11.0 kW","Certificates and Declarations/RoHS Date":"20240508","Certificates and Declarations/REACH Date":"20250905","Output Current, Light-Overload Use (IlD)":"46.2 A","Certificates and Declarations/RoHS Information":"Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019","Certificates and Declarations/REACH Information":"True - contains substances > 0.1 mass percentage"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3axd50000417414","alternativesUrl":"https://aoctrl.com/api/mcp/products/3AXD50000417414/alternatives.json"},"ai":{"faq":[{"question":"What compliance documentation does ABB provide for this drive?","answer":"RoHS compliance per EU Directive 2011/65/EU and Amendment 2015/863 (date 20240508). REACH declaration (date 20250905) confirms substances above 0.1 mass percentage. SCIP number f1c9bd3a-ea8b-410d-bd78-7d4098ee31cf Finland is registered."},{"question":"What is the altitude rating for 3AXD50000417414?","answer":"Rated for installation at altitudes up to 1000 m without derating. Above that, consult the drive's derating curves."},{"question":"What are the key output ratings for this drive?","answer":"Normal-duty output: 11 kW at 46.7 A. Heavy-duty: 7.5 kW at 30.8 A. Light-overload: 11.0 kW at 46.2 A. Input voltage 200-240 V three-phase."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AXD50000417414","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AXD50000417414 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}