{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AXD50000417537","brand":"ABB","brandSlug":"abb","productSlug":"3AXD50000417537","canonicalUrl":"https://aoctrl.com/abb/3AXD50000417537","factsUrl":"https://aoctrl.com/api/mcp/products/3AXD50000417537","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACS580-01 general-purpose wall-mounted drive, 3AXD50000417537, 4 kW normal-use output, 16.9 A, 200-240 V 3-phase, IP55, R1 frame, CAN interface.","salesMarkdown":"The ABB 3AXD50000417537 is an ACS580-01-018A-2+B056 general-purpose wall-mounted drive rated for 4 kW normal-use output at 16.9 A on a 200-240 V three-phase supply. Heavy-duty use drops to 3.0 kW and 10.6 A, so the normal-use figure governs the motor sizing for most constant-torque loads; the heavy-duty curve applies when ambient temperature or duty cycle pushes the thermal limit. The R1 frame size and IP55 enclosure with NEMA Type 12 rating mean this drive mounts directly on a wall or machine frame in dusty, washdown-adjacent environments — no separate cabinet needed for most food-and-bev or light industrial lines. Standby loss of 13 W keeps the panel heat load low when the motor is stopped. The drive carries 2 analog inputs, 2 analog outputs, and 6 digital inputs / 3 digital outputs — enough for basic speed reference, feedback, and start/stop control without an expansion module. Communication is CAN-based; there is no onboard industrial Ethernet port, so if the line uses PROFINET or EtherNet/IP, plan for an optional fieldbus adapter.","metaTitle":"ABB 3AXD50000417537 ACS580-01-018A-2+B056 Drive, 4 kW, 16.9","metaDescription":"ABB ACS580-01 general-purpose wall-mounted drive, 4 kW normal-use output, 16.9 A, 200-240 V 3-phase, IP55, R1 frame, CAN interface. Active production. RFQ for lead time.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 240V"],"specifications":{"SCIP":"12216470-2923-46fb-9b3c-c7084d490da0 Finland","Includes":"With control unit","Frame Size":"R1","Standby Loss":"13 W","Analog Inputs":"2","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Wall-mounted","WEEE Category":"5. Small Equipment (No External Dimension More Than 50 cm)","Analog Outputs":"2","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Temperature Rating":"Maximum 40 °C","Enclosure Type NEMA":"Type12","Input Voltage (Uin)":"200 ... 240 V","Degree of Protection":"IP55","Apparent Power Output":"7.2 kV·A","Communication Protocol":"CAN","Power Consumption (@Pcons)":"230 W","Operating Humidity (RHamβ)":"95","Multiple Battery Information":"Lithium Coin, CR2032, 220 mAh, 3 V, 1 pc, 3 g","Number of Digital In/Outputs":"6 / 3","Number of Hardware Interfaces":"Industrial Ethernet 0","Output Power, Normal Use (Pn)":"4 kW","Output Current, Normal Use (In)":"16.9 A","Output Power, Heavy-Duty Use (PhD)":"3.0 kW","Output Current, Heavy-Duty Use (IhD)":"10.6 A","Output Power, Light-Overload Use (PlD)":"4.0 kW","Certificates and Declarations/RoHS Date":"20240508","Certificates and Declarations/REACH Date":"20250905","Output Current, Light-Overload Use (IlD)":"16.7 A","Certificates and Declarations/RoHS Information":"Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019","Certificates and Declarations/REACH Information":"True - contains substances > 0.1 mass percentage"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3axd50000417537","alternativesUrl":"https://aoctrl.com/api/mcp/products/3AXD50000417537/alternatives.json"},"ai":{"faq":[{"question":"What compliance documentation is available for this drive?","answer":"RoHS compliance follows EU Directive 2011/65/EU and Amendment 2015/863 (date 2024-05-08). REACH confirms substances above 0.1% mass percentage. The SCIP number is 12216470-2923-46fb-9b3c-c7084d490da0 (Finland)."},{"question":"What is the normal-use output rating for this drive?","answer":"Normal-use (light-overload) output is 4 kW at 16.9 A. Heavy-duty use is 3.0 kW at 10.6 A. The normal-use figure governs motor sizing for constant-torque applications."},{"question":"What enclosure rating does this drive have?","answer":"IP55 with NEMA Type 12, suitable for wall mounting in dusty or washdown-adjacent environments without a separate cabinet."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AXD50000417537","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AXD50000417537 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}