{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AXD50000417605","brand":"ABB","brandSlug":"abb","productSlug":"3AXD50000417605","canonicalUrl":"https://aoctrl.com/abb/3AXD50000417605","factsUrl":"https://aoctrl.com/api/mcp/products/3AXD50000417605","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACS580-01 general-purpose wall-mounted drive, 37 kW / 144 A normal use, 200-240 V 3-phase, IP55, frame R6, with control unit.","salesMarkdown":"The ABB 3AXD50000417605 is an ACS580-01 general-purpose wall-mounted drive rated for 37 kW normal-use output at 144 A on a 200-240 V three-phase supply. It carries IP55 and NEMA Type12 protection, so it handles dust and hose-down well enough for most washdown or outdoor-adjacent spots out here in the grease. Frame R6, ships with the control unit included. ## Ratings that matter for the route Normal-use output is 37 kW / 144 A; heavy-duty use drops to 30.0 kW / 114 A, and light-overload use stays at 37 kW / 143 A. Input frequency range 47.5-63 Hz covers 50 and 60 Hz grids without a firmware tweak. Standby loss is 22 W, so it won't cook the panel when the motor's idle. ## What's on the box Wall-mounted, frame R6. Two analog inputs, two analog outputs, six digital inputs and three digital outputs. Communication is CAN — no onboard Ethernet, so if you need Modbus TCP or PROFINET you'll add an option module. Ambient temp max 40 °C; operating humidity up to 95%. Efficiency class IE2. Includes a lithium coin cell CR2032 for the real-time clock.","metaTitle":"ABB 3AXD50000417605 ACS580-01 Drive, 37 kW, 144 A, IP55","metaDescription":"Active-production ABB ACS580-01 wall-mounted drive, 37 kW normal use, 144 A output, IP55/NEMA 12, IE2, 200-240 V 3-phase. RoHS/REACH compliant. RFQ for lead time.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 240V"],"specifications":{"SCIP":"17a7c876-3c0e-4fce-930a-1904c59b53dd Finland","Includes":"With control unit","Frame Size":"R6","Standby Loss":"22 W","Analog Inputs":"2","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Wall-mounted","WEEE Category":"4. Large Equipment (Any External Dimension More Than 50 cm)","Analog Outputs":"2","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Temperature Rating":"Maximum 40 °C","Enclosure Type NEMA":"Type12","Input Voltage (Uin)":"200 ... 240 V","Degree of Protection":"IP55","Apparent Power Output":"57 kV·A","Communication Protocol":"CAN","Power Consumption (@Pcons)":"1932 W","Operating Humidity (RHamβ)":"95","Multiple Battery Information":"Lithium Coin, CR2032, 220 mAh, 3 V, 1 pc, 3 g","Number of Digital In/Outputs":"6 / 3","Number of Hardware Interfaces":"Industrial Ethernet 0","Output Power, Normal Use (Pn)":"37 kW","Output Current, Normal Use (In)":"144 A","Output Power, Heavy-Duty Use (PhD)":"30.0 kW","Output Current, Heavy-Duty Use (IhD)":"114 A","Output Power, Light-Overload Use (PlD)":"37 kW","Certificates and Declarations/RoHS Date":"20240508","Certificates and Declarations/REACH Date":"20250905","Output Current, Light-Overload Use (IlD)":"143 A","Certificates and Declarations/RoHS Information":"Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019","Certificates and Declarations/REACH Information":"True - contains substances > 0.1 mass percentage"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3axd50000417605","alternativesUrl":"https://aoctrl.com/api/mcp/products/3AXD50000417605/alternatives.json"},"ai":{"faq":[{"question":"What compliance documentation does this drive carry?","answer":"RoHS compliant per EU Directive 2011/65/EU and Amendment 2015/863, and REACH declared with substances above 0.1% mass. SCIP number 17a7c876-3c0e-4fce-930a-1904c59b53dd Finland is registered."},{"question":"What are the key ratings for this ACS580-01 drive?","answer":"Normal-use output is 37 kW at 144 A; heavy-duty use is 30.0 kW at 114 A. Input 200-240 V three-phase, 47.5-63 Hz. IP55 / NEMA Type12 enclosure, IE2 efficiency, max ambient 40 °C."},{"question":"What communication protocol does this drive support?","answer":"Built-in CAN communication. No onboard industrial Ethernet; an option module is needed for protocols like Modbus TCP or PROFINET."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AXD50000417605","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AXD50000417605 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}