{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AXD50000417643","brand":"ABB","brandSlug":"abb","productSlug":"3AXD50000417643","canonicalUrl":"https://aoctrl.com/abb/3AXD50000417643","factsUrl":"https://aoctrl.com/api/mcp/products/3AXD50000417643","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACH580-01 series, LV AC wall-mounted drive, 0.75 kW, 4.7 A, 200-240 V, IP21, BACnet, frame R1.","salesMarkdown":"The ABB 3AXD50000417643 is the order code for an ACH580-01-04A7-2 drive: a wall-mounted, low-voltage AC drive for HVAC applications, rated 0.75 kW normal use (Pn) at 4.7 A output current (In) on a 200-240 V three-phase supply. Frame size R1, IP21 enclosure, NEMA Type 1. It carries a BACnet communication interface as standard. Normal-use output is 0.75 kW at 4.7 A; heavy-duty use (PhD) derates to 0.6 kW at 3.5 A (IhD). Light-overload (PlD) matches the normal-use power at 0.75 kW, but the current limit is 4.6 A (IlD) — slightly below the normal-use 4.7 A, so the thermal headroom is tighter under light overload. The 13 W standby loss matters for continuous HVAC fan operation where the drive idles between calls. Wall-mounted, frame R1. Ambient temperature limited to 40 °C maximum; altitude derating starts above 1000 m. IP21 / NEMA Type 1 means drip-proof but not hose-down — suitable for indoor equipment rooms, not washdown areas. The 59 dB(A) sound level is moderate; expect audible fan noise in a quiet mechanical room. Two analog inputs, two analog outputs, six digital inputs, three digital outputs. No onboard industrial Ethernet (0 hardware interfaces for that), so BACnet MS/TP over RS-485 is the primary fieldbus. The control unit is included; the module also carries a CR2032 lithium coin cell (220 mAh, 3 V) for real-time clock backup.","metaTitle":"ABB 3AXD50000417643 ACH580-01 VFD, 0.75 kW, 4.7 A, 230 V","metaDescription":"ABB ACH580-01-04A7-2 VFD, 0.75 kW normal use, 4.7 A output, 200-240 V 3-phase, IP21, BACnet, active production. Sourced to order via RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 240V"],"specifications":{"SCIP":"8105d671-49fa-4c1c-836d-baf56982886a Finland","Altitude":"1000 m","Includes":"Control unit","Frame Size":"R1","Sound dB (A)":"59 dB(A)","Standby Loss":"13 W","Analog Inputs":"2","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Wall-mounted","WEEE Category":"5. Small Equipment (No External Dimension More Than 50 cm)","Analog Outputs":"2","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Temperature Rating":"Maximum 40 °C","Enclosure Type NEMA":"Type1","Input Voltage (Uin)":"200 ... 240 V","Degree of Protection":"IP21","Apparent Power Output":"1.9 kV·A","Communication Protocol":"BACNET","Power Consumption (@Pcons)":"53 W","Operating Humidity (RHamβ)":"95","Multiple Battery Information":"Lithium Coin, CR2032, 220 mAh, 3 V, 1 pc, 3 g","Number of Digital In/Outputs":"6 / 3","Number of Hardware Interfaces":"Industrial Ethernet 0","Output Power, Normal Use (Pn)":"0.75 kW","Output Current, Normal Use (In)":"4.7 A","Output Power, Heavy-Duty Use (PhD)":"0.6 kW","Output Current, Heavy-Duty Use (IhD)":"3.5 A","Output Power, Light-Overload Use (PlD)":"0.75 kW","Certificates and Declarations/RoHS Date":"20240508","Certificates and Declarations/REACH Date":"20250905","Output Current, Light-Overload Use (IlD)":"4.6 A","Certificates and Declarations/RoHS Information":"Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019","Certificates and Declarations/REACH Information":"True - contains substances > 0.1 mass percentage"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3axd50000417643","alternativesUrl":"https://aoctrl.com/api/mcp/products/3AXD50000417643/alternatives.json"},"ai":{"faq":[{"question":"What is the SCIP number for this drive?","answer":"SCIP number 8105d671-49fa-4c1c-836d-baf56982886a, registered in Finland."},{"question":"What compliance documentation is available?","answer":"RoHS compliant per EU Directive 2011/65/EU (RoHS date 20240508), REACH registered (date 20250905, contains substances >0.1% mass)."},{"question":"What is the altitude rating?","answer":"Rated for installation up to 1000 m altitude without derating."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AXD50000417643","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AXD50000417643 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}