{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AXD50000417889","brand":"ABB","brandSlug":"abb","productSlug":"3AXD50000417889","canonicalUrl":"https://aoctrl.com/abb/3AXD50000417889","factsUrl":"https://aoctrl.com/api/mcp/products/3AXD50000417889","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACH580-01 wall-mounted HVAC drive, 22 kW normal use, 89 A output, 200-240 V 3-phase, IP55, NEMA 12, BACnet, IE2.","salesMarkdown":"## Drive selection memo for a 22 kW HVAC fan or pump The ABB 3AXD50000417889 is a wall-mounted drive sized for a 22 kW motor at 200-240 V three-phase input. Normal-use output current is 89 A; heavy-duty use drops to 18.5 kW / 75 A for tougher loads like positive-displacement pumps. Light-overload use is rated 22.0 kW / 88 A. The drive includes a control unit and is frame size R5. The 200-240 V input and 3-phase output match North American 208/230 V commercial supply. The 89 A normal-use rating handles a 22 kW motor at full load; if your load profile is heavy-duty (e.g., high starting torque), the drive is rated 75 A continuous. Standby loss is 19 W, which matters for energy code compliance on continuously powered drives. Efficiency is IE2. Enclosure is IP55 / NEMA Type12, so it's suitable for indoor washdown or dusty environments — think HVAC mechanical rooms or light industrial floors. Ambient temperature max is 40 °C; operating humidity up to 95% RH. Wall-mounted, so no floor space needed. Built-in BACnet communication (no Industrial Ethernet interface) makes this a direct fit for building management system integration. Two analog inputs and two analog outputs cover a speed reference and feedback; six digital inputs and three digital outputs handle start/stop, fault reset, and status. The drive includes a lithium coin cell (CR2032, 220 mAh) for real-time clock backup.","metaTitle":"3AXD50000417889 ACH580-01 HVAC Drive, 22 kW, 89 A, 230 V","metaDescription":"Active ABB ACH580-01 wall-mounted HVAC drive, 22 kW normal use, 89 A output, 200-240 V 3-phase, IP55, NEMA 12, BACnet, IE2. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 240V"],"specifications":{"SCIP":"567c5ced-c536-4a8b-933d-885c159a15d8 Finland","Includes":"Control unit","Frame Size":"R5","Standby Loss":"19 W","Analog Inputs":"2","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Wall-mounted","WEEE Category":"4. Large Equipment (Any External Dimension More Than 50 cm)","Analog Outputs":"2","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Temperature Rating":"Maximum 40 °C","Enclosure Type NEMA":"Type12","Input Voltage (Uin)":"200 ... 240 V","Degree of Protection":"IP55","Apparent Power Output":"35 kV·A","Communication Protocol":"BACNET","Power Consumption (@Pcons)":"876 W","Operating Humidity (RHamβ)":"95","Multiple Battery Information":"Lithium Coin, CR2032, 220 mAh, 3 V, 1 pc, 3 g","Number of Digital In/Outputs":"6 / 3","Number of Hardware Interfaces":"Industrial Ethernet 0","Output Power, Normal Use (Pn)":"22 kW","Output Current, Normal Use (In)":"89 A","Output Power, Heavy-Duty Use (PhD)":"18.5 kW","Output Current, Heavy-Duty Use (IhD)":"75 A","Output Power, Light-Overload Use (PlD)":"22.0 kW","Certificates and Declarations/RoHS Date":"20240508","Certificates and Declarations/REACH Date":"20250905","Output Current, Light-Overload Use (IlD)":"88 A","Certificates and Declarations/RoHS Information":"Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019","Certificates and Declarations/REACH Information":"True - contains substances > 0.1 mass percentage"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3axd50000417889","alternativesUrl":"https://aoctrl.com/api/mcp/products/3AXD50000417889/alternatives.json"},"ai":{"faq":[{"question":"What is the SCIP number for this drive?","answer":"SCIP number is 567c5ced-c536-4a8b-933d-885c159a15d8, registered in Finland."},{"question":"What compliance documentation is available?","answer":"RoHS compliant per EU Directive 2011/65/EU and Amendment 2015/863; REACH declaration confirms substances above 0.1% mass percentage. RoHS date 20240508, REACH date 20250905."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AXD50000417889","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AXD50000417889 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}