{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AXD50000417971","brand":"ABB","brandSlug":"abb","productSlug":"3AXD50000417971","canonicalUrl":"https://aoctrl.com/abb/3AXD50000417971","factsUrl":"https://aoctrl.com/api/mcp/products/3AXD50000417971","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACQ580-01-012A-2 LV AC wall-mounted drive, 3 kW, 12.0 A, 200-240 V, IP21, NEMA 1, frame R1.","salesMarkdown":"The ABB ACQ580-01-012A-2 (3AXD50000417971) is a low-voltage AC wall-mounted drive rated for 3 kW output power, 12.0 A continuous current, on a 200-240 V three-phase supply. It's built for water and wastewater applications — the 'ACQ' prefix and the IEC designation in the description confirm that focus. Frame size R1 keeps it compact on the wall, and the IP21 / NEMA 1 enclosure handles indoor environments without extra cabinet protection. Three output current ratings define the load capability: 12.0 A for normal use, 7.5 A for heavy-duty use, and 11.8 A for light-overload use. The drive carries 2 analog inputs, 2 analog outputs, 6 digital inputs, and 3 digital outputs — enough for basic pump control with feedback. Communication is via CAN bus, not Ethernet (0 industrial Ethernet interfaces), so plan for a CAN network or a gateway if the system uses PROFINET or EtherNet/IP. Standby loss is 13 W, and total power consumption at rated load is 143 W.","metaTitle":"ABB 3AXD50000417971 ACQ580-01-012A-2 Drive, 3 kW, 12 A","metaDescription":"ABB ACQ580-01-012A-2 LV AC wall-mounted drive, 3 kW, 12.0 A, 230 V, IP21, NEMA 1, active production, RoHS/REACH compliant.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 240V"],"specifications":{"SCIP":"8105d671-49fa-4c1c-836d-baf56982886a Finland","Altitude":"4000 m","Includes":"Control unit","Frame Size":"R1","Power Factor":"0.98","Sound dB (A)":"59 dB(A)","Standby Loss":"13 W","Analog Inputs":"2","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Wall-mounted","WEEE Category":"5. Small Equipment (No External Dimension More Than 50 cm)","Analog Outputs":"2","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Temperature Rating":"Maximum 40 °C","Enclosure Type NEMA":"Type1","Input Voltage (Uin)":"200 ... 240 V","Degree of Protection":"IP21","Apparent Power Output":"4.8 kV·A","Communication Protocol":"CAN","Power Consumption (@Pcons)":"143 W","Operating Humidity (RHamβ)":"5 ... 95","Multiple Battery Information":"Lithium Coin; CR2032; 220 mAh; 3 V; 1 pc; 3 g","Number of Digital In/Outputs":"6 / 3","Number of Hardware Interfaces":"Industrial Ethernet 0","Output Power, Normal Use (Pn)":"3 kW","Output Current, Normal Use (In)":"12.0 A","Output Power, Heavy-Duty Use (PhD)":"2.2 kW","Output Current, Heavy-Duty Use (IhD)":"7.5 A","Output Power, Light-Overload Use (PlD)":"3 kW","Certificates and Declarations/RoHS Date":"20240508","Certificates and Declarations/REACH Date":"20250905","Output Current, Light-Overload Use (IlD)":"11.8 A","Certificates and Declarations/RoHS Information":"Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019","Certificates and Declarations/REACH Information":"True - contains substances > 0.1 mass percentage"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3axd50000417971","alternativesUrl":"https://aoctrl.com/api/mcp/products/3AXD50000417971/alternatives.json"},"ai":{"faq":[{"question":"What compliance documentation does this drive have?","answer":"RoHS compliant per EU Directive 2011/65/EU and amendment 2015/863 (date 20240508), REACH registered (date 20250905), and SCIP number 8105d671-49fa-4c1c-836d-baf56982886a Finland is on file."},{"question":"What is the altitude rating for this drive?","answer":"Rated for installation up to 4000 m altitude without derating."},{"question":"What are the key output current ratings?","answer":"Normal-use output current is 12.0 A, heavy-duty use is 7.5 A, and light-overload use is 11.8 A."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AXD50000417971","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AXD50000417971 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}