{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AXD50000418039","brand":"ABB","brandSlug":"abb","productSlug":"3AXD50000418039","canonicalUrl":"https://aoctrl.com/abb/3AXD50000418039","factsUrl":"https://aoctrl.com/api/mcp/products/3AXD50000418039","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACQ580-01 series, LV AC wall-mounted drive for water and wastewater, IEC: Pn 22 kW, 89 A, 230 V (3AXD50000418039).","salesMarkdown":"The ABB 3AXD50000418039 is a wall-mounted drive for water and wastewater. It delivers 22 kW in normal use (89 A output) from a 200–240 V three-phase supply, with heavy-duty capability at 18.5 kW (75 A). Active in production. The 89 A normal-use output (In) is the number that governs cable sizing and thermal stress in continuous-duty pumping. Heavy-duty use at 75 A (IhD) covers variable-torque loads like centrifugal pumps that never hit full current. Light-overload use at 88 A (IlD) sits just below the normal rating — essentially the same thermal headroom. The 35 kV·A apparent power output gives a quick transformer sizing check. Standby loss of 19 W means the drive draws negligible power when the pump is idle, a real consideration in remote or solar-fed installations. Input voltage range is 200–240 V three-phase. Frequency tolerance is 47.5–63 Hz. Maximum ambient temperature is 40 °C, with 5–95 % humidity and altitude up to 4000 m. Efficiency is IE2, with a power factor of 0.98. That 0.98 is the drive's input power factor — not the motor's — meaning the drive presents a near-unity load to the supply, reducing reactive current in the distribution wiring. Acoustic noise is 63 dB(A) — noticeable in a quiet pump house but not intrusive. ## I/O and communication — what's on board The drive carries 2 analog inputs, 2 analog outputs, 6 digital inputs, and 3 digital outputs. That's enough for a basic pump control scheme (pressure transducer, flow meter, start/stop, run status) without an expansion module. Communication is CAN — no onboard Ethernet. If you need Modbus TCP or PROFINET, an optional fieldbus adapter is required; the hardware interface count shows zero Industrial Ethernet ports. Plan for that in the network architecture.","metaTitle":"ABB 3AXD50000418039 ACQ580-01-089A-2 Drive, 22 kW, 89 A, 230","metaDescription":"ABB ACQ580-01 wall-mounted drive for water/wastewater. 22 kW normal use, 89 A output, 230 V 3-phase input. Active production. RoHS/REACH compliant. Frame R5, IP21.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 240V"],"specifications":{"SCIP":"78feb6f4-2343-45e6-a509-fef3119deda6 Finland","Altitude":"4000 m","Includes":"Control unit","Frame Size":"R5","Power Factor":"0.98","Sound dB (A)":"63 dB(A)","Standby Loss":"19 W","Analog Inputs":"2","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Wall-mounted","WEEE Category":"4. Large Equipment (Any External Dimension More Than 50 cm)","Analog Outputs":"2","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Temperature Rating":"Maximum 40 °C","Enclosure Type NEMA":"Type1","Input Voltage (Uin)":"200 ... 240 V","Degree of Protection":"IP21","Apparent Power Output":"35 kV·A","Communication Protocol":"CAN","Power Consumption (@Pcons)":"876 W","Operating Humidity (RHamβ)":"5 ... 95","Multiple Battery Information":"Lithium Coin; CR2032; 220 mAh; 3 V; 1 pc; 3 g","Number of Digital In/Outputs":"6 / 3","Number of Hardware Interfaces":"Industrial Ethernet 0","Output Power, Normal Use (Pn)":"22 kW","Output Current, Normal Use (In)":"89 A","Output Power, Heavy-Duty Use (PhD)":"18.5 kW","Output Current, Heavy-Duty Use (IhD)":"75 A","Output Power, Light-Overload Use (PlD)":"22 kW","Certificates and Declarations/RoHS Date":"20240508","Certificates and Declarations/REACH Date":"20250905","Output Current, Light-Overload Use (IlD)":"88 A","Certificates and Declarations/RoHS Information":"Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019","Certificates and Declarations/REACH Information":"True - contains substances > 0.1 mass percentage"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3axd50000418039","alternativesUrl":"https://aoctrl.com/api/mcp/products/3AXD50000418039/alternatives.json"},"ai":{"faq":[{"question":"What is the SCIP number for this drive?","answer":"The SCIP number is 78feb6f4-2343-45e6-a509-fef3119deda6 Finland."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AXD50000418039","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AXD50000418039 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}