{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AXD50000418084","brand":"ABB","brandSlug":"abb","productSlug":"3AXD50000418084","canonicalUrl":"https://aoctrl.com/abb/3AXD50000418084","factsUrl":"https://aoctrl.com/api/mcp/products/3AXD50000418084","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACQ580-01-276A-2 LV AC wall-mounted drive, IEC: Pn 75 kW, 276 A, 230 V, IP21, NEMA 1, R8 frame.","salesMarkdown":"The 3AXD50000418084 is an ABB ACQ580-01-276A-2 LV AC wall-mounted drive, built for water and wastewater applications. It delivers 75 kW normal-duty output (Pn) at 276 A continuous on a 200–240 V three-phase supply. Heavy-duty use drops to 55 kW and 211 A; light-overload holds at 75 kW with 273 A. That 0.98 power factor keeps the line draw clean, and standby loss sits at 26 W — relevant for panel heat calculations. Enclosure is IP21 with NEMA 1 rating, wall-mounted in an R8 frame. Maximum ambient temperature is 40 °C; altitude rating goes to 4000 m. The drive has 2 analog inputs, 2 analog outputs, 6 digital inputs, and 3 digital outputs. Communication is CAN-based — no onboard Ethernet, so plan for a gateway if you need Modbus TCP or PROFINET. Wall-mount only — no floor-stand option in this frame. The R8 frame is sized for the 276 A output; verify gland-plate clearance for incoming 200–240 V three-phase cable and motor leads. The drive includes a control unit and a lithium coin cell (CR2032, 220 mAh) for real-time clock backup. Sound level is 65 dB(A) — noticeable in a quiet pump room.","metaTitle":"3AXD50000418084 ABB ACQ580-01-276A-2 LV AC Drive, 75 kW, 276","metaDescription":"Active ABB ACQ580-01-276A-2 LV AC drive, 75 kW normal-duty, 276 A output at 230 V. IP21, NEMA 1, R8 frame. RoHS/REACH compliant. Order to RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 240V"],"specifications":{"SCIP":"c68079d0-d1d5-4fa0-b4a7-6e12fd5d3c68 Finland","Altitude":"4000 m","Includes":"Control unit","Frame Size":"R8","Power Factor":"0.98","Sound dB (A)":"65 dB(A)","Standby Loss":"26 W","Analog Inputs":"2","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Wall-mounted","WEEE Category":"4. Large Equipment (Any External Dimension More Than 50 cm)","Analog Outputs":"2","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Temperature Rating":"Maximum 40 °C","Enclosure Type NEMA":"Type1","Input Voltage (Uin)":"200 ... 240 V","Degree of Protection":"IP21","Apparent Power Output":"110 kV·A","Communication Protocol":"CAN","Power Consumption (@Pcons)":"3571 W","Operating Humidity (RHamβ)":"5 ... 95","Multiple Battery Information":"Lithium Coin; CR2032; 220 mAh; 3 V; 1 pc; 3 g","Number of Digital In/Outputs":"6 / 3","Number of Hardware Interfaces":"Industrial Ethernet 0","Output Power, Normal Use (Pn)":"75 kW","Output Current, Normal Use (In)":"276 A","Output Power, Heavy-Duty Use (PhD)":"55 kW","Output Current, Heavy-Duty Use (IhD)":"211 A","Output Power, Light-Overload Use (PlD)":"75 kW","Certificates and Declarations/RoHS Date":"20240508","Certificates and Declarations/REACH Date":"20250905","Output Current, Light-Overload Use (IlD)":"273 A","Certificates and Declarations/RoHS Information":"Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019","Certificates and Declarations/REACH Information":"True - contains substances > 0.1 mass percentage"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3axd50000418084","alternativesUrl":"https://aoctrl.com/api/mcp/products/3AXD50000418084/alternatives.json"},"ai":{"faq":[{"question":"What compliance documentation is available?","answer":"RoHS compliant per EU Directive 2011/65/EU and Amendment 2015/863 (date 20240508); REACH compliant with substances >0.1% declared (date 20250905). SCIP number c68079d0-d1d5-4fa0-b4a7-6e12fd5d3c68 Finland."},{"question":"What are the key output ratings?","answer":"Normal-duty: 75 kW, 276 A. Heavy-duty: 55 kW, 211 A. Light-overload: 75 kW, 273 A. All at 200–240 V three-phase input."},{"question":"What enclosure protection does it have?","answer":"IP21 with NEMA 1 rating, wall-mounted."},{"question":"What communication protocol does it use?","answer":"CAN protocol. No onboard industrial Ethernet interfaces."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AXD50000418084","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AXD50000418084 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}