{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AXD50000418138","brand":"ABB","brandSlug":"abb","productSlug":"3AXD50000418138","canonicalUrl":"https://aoctrl.com/abb/3AXD50000418138","factsUrl":"https://aoctrl.com/api/mcp/products/3AXD50000418138","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACQ580-01, LV AC wall-mounted drive for water and wastewater, IEC: Pn 4 kW, 16.9 A, 230 V, frame R1, IP55.","salesMarkdown":"The 3AXD50000418138: The drive accepts 47.5–63 Hz line frequency and draws 230 W at rated load. Standby loss sits at 13 W — worth noting if the drive idles for long periods. Efficiency is rated IE2. Normal-use output current is 16.9 A; light-overload use pushes that to 16.7 A. Heavy-duty use drops to 10.6 A — that's the number to size against if the motor runs a pump with variable head or frequent starts. Apparent power output is 7.2 kV·A. Enclosure is IP55 with NEMA Type 12, so it handles hose-down and dust in treatment plants. Ambient temperature max is 40 °C; altitude rating goes to 4000 m — no derate worry at typical plant elevations. Operating humidity spans 5–95% RH. The drive includes a control unit and communicates via CAN. It has 2 analog inputs, 2 analog outputs, and 6 digital inputs / 3 digital outputs — enough for basic pump control with feedback. No onboard industrial Ethernet; that's a separate hardware interface count of 0.","metaTitle":"ABB 3AXD50000418138 ACQ580-01 Drive, 4 kW, 16.9 A, 230 V","metaDescription":"ABB ACQ580-01 wall-mounted drive, 4 kW normal use, 16.9 A output, 230 V input. IP55, NEMA 12, frame R1. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 240V"],"specifications":{"SCIP":"12216470-2923-46fb-9b3c-c7084d490da0 Finland","Altitude":"4000 m","Includes":"Control unit","Frame Size":"R1","Power Factor":"0.98","Sound dB (A)":"59 dB(A)","Standby Loss":"13 W","Analog Inputs":"2","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Wall-mounted","WEEE Category":"5. Small Equipment (No External Dimension More Than 50 cm)","Analog Outputs":"2","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Temperature Rating":"Maximum 40 °C","Enclosure Type NEMA":"Type12","Input Voltage (Uin)":"200 ... 240 V","Degree of Protection":"IP55","Apparent Power Output":"7.2 kV·A","Communication Protocol":"CAN","Power Consumption (@Pcons)":"230 W","Operating Humidity (RHamβ)":"5 ... 95","Multiple Battery Information":"Lithium Coin; CR2032; 220 mAh; 3 V; 1 pc; 3 g","Number of Digital In/Outputs":"6 / 3","Number of Hardware Interfaces":"Industrial Ethernet 0","Output Power, Normal Use (Pn)":"4 kW","Output Current, Normal Use (In)":"16.9 A","Output Power, Heavy-Duty Use (PhD)":"3 kW","Output Current, Heavy-Duty Use (IhD)":"10.6 A","Output Power, Light-Overload Use (PlD)":"4 kW","Certificates and Declarations/RoHS Date":"20240508","Certificates and Declarations/REACH Date":"20250905","Output Current, Light-Overload Use (IlD)":"16.7 A","Certificates and Declarations/RoHS Information":"Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019","Certificates and Declarations/REACH Information":"True - contains substances > 0.1 mass percentage"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3axd50000418138","alternativesUrl":"https://aoctrl.com/api/mcp/products/3AXD50000418138/alternatives.json"},"ai":{"faq":[{"question":"What compliance documentation does this drive have?","answer":"RoHS compliant per EU Directive 2011/65/EU and Amendment 2015/863 (date 20240508). REACH declaration confirms substances > 0.1% mass (date 20250905). SCIP number 12216470-2923-46fb-9b3c-c7084d490da0 Finland."},{"question":"What are the key output ratings for this drive?","answer":"Normal use: 4 kW, 16.9 A. Heavy-duty use: 3 kW, 10.6 A. Light-overload use: 4 kW, 16.7 A. Input voltage: 200–240 V three-phase."},{"question":"What enclosure protection does it have?","answer":"IP55 and NEMA Type 12, rated for washdown and dust environments. Maximum ambient temperature 40 °C, altitude 4000 m."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AXD50000418138","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AXD50000418138 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}