{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AXD50000465125","brand":"ABB","brandSlug":"abb","productSlug":"3AXD50000465125","canonicalUrl":"https://aoctrl.com/abb/3AXD50000465125","factsUrl":"https://aoctrl.com/api/mcp/products/3AXD50000465125","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACQ580-PC-059A-2, LV AC Packaged drive with circuit breaker and fuse, Frame R3, 20 Hp, 59.4 A, 208-240 V, 3-phase, IP21, NEMA Type 1.","salesMarkdown":"The ABB 3AXD50000465125 is an LV AC packaged drive, Frame R3, rated 20 Hp at 59.4 A output current on 208-240 V three-phase input. It ships as a NEMA Type 1 enclosure with IP21 ingress protection, and includes an integrated circuit breaker and fuse. Frame R3 determines the physical footprint and the bus-bar pattern. Panel layout should account for the NEMA Type 1 enclosure dimensions.","metaTitle":"ABB 3AXD50000465125 ACQ580 Drive, 20 Hp, 59.4 A, Frame R3","metaDescription":"ABB ACQ580- PC-059A-2 LV AC packaged drive, 20 Hp, 59.4 A, 208-240 V, 3-phase, Frame R3, IP21, NEMA 1. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 240V"],"specifications":{"Frame Size":"R3","Frequency (f)":"50/60 Hz","lifecycle_stage":"current","Number of Phases":"3-phase","Enclosure Type NEMA":"Type1","Input Voltage (Uin)":"208 ... 240 V","Degree of Protection":"IP21","Technical UL/Output Power, Light-Overload Use (UL)":"20 Hp","Technical UL/Output Current, Light-Overload Use (UL)":"59.4 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3axd50000465125","alternativesUrl":"https://aoctrl.com/api/mcp/products/3AXD50000465125/alternatives.json"},"ai":{"faq":[{"question":"What is the frame size of this drive?","answer":"Frame R3. That determines the physical mounting dimensions and the bus-bar pattern for incoming power and motor connections."},{"question":"What input voltage and frequency does this drive accept?","answer":"208-240 V three-phase at 50/60 Hz. It covers North American 208 V and 240 V services."},{"question":"What is the output rating in horsepower and amps?","answer":"20 Hp light-overload (UL) at 59.4 A continuous output current."},{"question":"What enclosure type and protection rating does it have?","answer":"NEMA Type 1 enclosure with IP21 ingress protection. Suitable for indoor installation in a clean, dry environment."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AXD50000465125","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AXD50000465125 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}