{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AXD50000707263","brand":"ABB","brandSlug":"abb","productSlug":"3AXD50000707263","canonicalUrl":"https://aoctrl.com/abb/3AXD50000707263","factsUrl":"https://aoctrl.com/api/mcp/products/3AXD50000707263","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACQ80-04-02kW2-4 LV AC drive module for solar pumps, 2.2 kW / 5.6 A normal duty, 380-480 V, IP20, CAN, Frame R0.","salesMarkdown":"The ABB 3AXD50000707263 is an ACQ80-04-02kW2-4 low-voltage AC drive module purpose-built for solar pump applications. It delivers 2.2 kW output power at 5.6 A in normal (light-overload) use, and 1.5 kW at 4 A in heavy-duty use — the rating that governs continuous motor operation in hot, high-irradiance conditions. Input accepts 380-480 V three-phase, 47.5-63 Hz, so it handles both 50 Hz and 60 Hz grids without derating. The drive includes a control unit, mounts as a module (Frame R0), and is rated IP20 for clean indoor panel environments. Normal-use output (2.2 kW / 5.6 A) matches the pump motor's nameplate for most solar tracking and booster applications. Heavy-duty output (1.5 kW / 4 A) is the rating to size against when ambient temperature hits 50 °C or the pump sees sustained overload — the drive's maximum ambient is 50 °C, so in a hot cabinet that heavy-duty number is the one that keeps the drive online. Standby loss is 15 W, power consumption at full load is 91 W — low enough that cabinet ventilation requirements are modest for a 2.2 kW class drive. The drive provides 2 analog inputs, 2 analog outputs, 6 digital inputs, and 3 digital outputs — enough for pressure transducer feedback, start/stop from a PLC or float switch, and a run-status relay. Communication is CAN-based, not Ethernet; if the site uses Modbus TCP or PROFINET, a separate gateway or option module is needed. The lithium coin cell (CR2032, 220 mAh) keeps real-time clock and parameter backup alive during power loss.","metaTitle":"ABB 3AXD50000707263 ACQ80 Solar Pump Drive, 2.2 kW, 5.6 A","metaDescription":"ABB ACQ80-04-02kW2-4 solar pump drive module, 2.2 kW / 5.6 A normal duty, 1.5 kW / 4 A heavy duty, 380-480 V, IP20, CAN, active production, RoHS/REACH compliant.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"SCIP":"97657ee2-2ad1-409a-811f-7a3734b200a6 Finland","Includes":"Control unit","Frame Size":"R0","Sound dB (A)":"63.10 dB(A)","Standby Loss":"15 W","Analog Inputs":"2","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Module","WEEE Category":"5. Small Equipment (No External Dimension More Than 50 cm)","Analog Outputs":"2","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Temperature Rating":"Maximum 50 °C","Enclosure Type NEMA":"Open Type","Input Voltage (Uin)":"380 ... 480 V","Degree of Protection":"IP20","Apparent Power Output":"4.0 kV·A","Communication Protocol":"CAN","Power Consumption (@Pcons)":"91 W","Operating Humidity (RHamβ)":"5 ... 95","Multiple Battery Information":"Lithium Coin, CR2032, 220 mAh, 3 V, 1 pc, 3 g","Number of Digital In/Outputs":"6 / 3","Number of Hardware Interfaces":"Industrial Ethernet 0","Output Power, Normal Use (Pn)":"2.2 kW","Output Current, Normal Use (In)":"5.6 A","Output Power, Heavy-Duty Use (PhD)":"1.5 kW","Output Current, Heavy-Duty Use (IhD)":"4 A","Output Power, Light-Overload Use (PlD)":"2.2 kW","Certificates and Declarations/RoHS Date":"20240603","Certificates and Declarations/REACH Date":"20250905","Output Current, Light-Overload Use (IlD)":"5.3 A","Certificates and Declarations/RoHS Information":"Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019","Certificates and Declarations/REACH Information":"True - contains substances > 0.1 mass percentage"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3axd50000707263","alternativesUrl":"https://aoctrl.com/api/mcp/products/3AXD50000707263/alternatives.json"},"ai":{"faq":[{"question":"What compliance documentation does this drive have?","answer":"RoHS compliant per EU Directive 2011/65/EU and Amendment 2015/863 (declaration date 20240603). REACH compliant with substances > 0.1% (declaration date 20250905). SCIP number 97657ee2-2ad1-409a-811f-7a3734b200a6 Finland."},{"question":"What is the heavy-duty output rating and why does it matter?","answer":"Heavy-duty output is 1.5 kW at 4 A. This is the rating to use when sizing the drive for continuous operation at 50 °C ambient or for pump loads with sustained overload — it ensures the drive stays within its thermal limits."},{"question":"What communication protocol does this drive use?","answer":"CAN. There is no onboard Industrial Ethernet interface (0 hardware interfaces for Industrial Ethernet), so integration into Modbus TCP or PROFINET networks requires an external gateway or option module."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AXD50000707263","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AXD50000707263 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}