{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AXD50000716579","brand":"ABB","brandSlug":"abb","productSlug":"3AXD50000716579","canonicalUrl":"https://aoctrl.com/abb/3AXD50000716579","factsUrl":"https://aoctrl.com/api/mcp/products/3AXD50000716579","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACS180 series, LV AC machinery drive module, 3AXD50000716579, 0.55 kW / 3.7 A normal use, 200-240 V 1-phase input, R0 frame, IP20.","salesMarkdown":"It delivers 0.55 kW normal-use output at 3.7 A from a 200-240 V single-phase supply, with a heavy-duty rating of 0.37 kW at 2.4 A. ## Duty Ratings and Load Profiles Three duty ratings let you match the drive to the application: normal use (Pn) at 0.55 kW / 3.7 A, light-overload (PlD) at 0.55 kW / 3.5 A, and heavy-duty (PhD) at 0.37 kW / 2.4 A. The UL listing mirrors these with 0.75 Hp normal and light-overload, and 0.5 Hp heavy-duty. For a constant-torque conveyor or pump, size on the heavy-duty current; for variable-torque fans, the normal-use figure gives more headroom. ## Input and Environment Runs on a single-phase 200-240 VAC input at 47-63 Hz, drawing 42 W typical power consumption. The apparent power output is rated at 1.5 kV·A. Enclosure is IP20 (open type per NEMA), so it's for panel-mount indoor use where it won't see washdown or dust. Altitude limit is 2000 m without derating. Onboard I/O includes 2 analog inputs, 1 analog output, and 4 digital inputs with 2 digital outputs. Communication is MODBUS over the built-in interface — no Industrial Ethernet on this variant, so plan for a serial or gateway connection if the network is PROFINET or EtherNet/IP.","metaTitle":"ABB 3AXD50000716579 ACS180 Drive Module, 0.55 kW, 3.7 A","metaDescription":"ABB ACS180 LV AC machinery drive module, R0 frame, 0.55 kW / 3.7 A normal use, 200-240 V 1-phase input. Active lifecycle. RoHS/REACH compliant. Order to RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 240V"],"specifications":{"SCIP":"8df33f0d-6fb9-4799-9075-9031a17c1386 Finland","Altitude":"2000 m","Includes":"Control unit","Frame Size":"R0","Power Factor":"0.98","Analog Inputs":"2","Frequency (f)":"47 ... 63 Hz","Mounting Type":"Module","WEEE Category":"5. Small Equipment (No External Dimension More Than 50 cm)","Analog Outputs":"1","lifecycle_stage":"current","Number of Phases":"1-phase","Enclosure Type NEMA":"Open Type","Input Voltage (Uin)":"200 ... 240 V","Degree of Protection":"IP20","Apparent Power Output":"1.5 kV·A","Communication Protocol":"MODBUS","Power Consumption (@Pcons)":"42 W","Operating Humidity (RHamβ)":"5 ... 95","Multiple Battery Information":"No battery / cell included","Number of Digital In/Outputs":"4 / 2","Number of Hardware Interfaces":"Industrial Ethernet 0","Output Power, Normal Use (Pn)":"0.55 kW","Output Current, Normal Use (In)":"3.7 A","Output Power, Heavy-Duty Use (PhD)":"0.37 kW","Output Current, Heavy-Duty Use (IhD)":"2.4 A","Output Power, Light-Overload Use (PlD)":"0.55 kW","Certificates and Declarations/RoHS Date":"20250106","Certificates and Declarations/REACH Date":"20250905","Output Current, Light-Overload Use (IlD)":"3.5 A","Technical UL/Output Power, Normal Use (UL)":"0.75 Hp","Technical UL/Output Current, Normal Use (UL)":"- A","Certificates and Declarations/RoHS Information":"Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019","Technical UL/Output Power, Heavy-Duty Use (UL)":"0.5 Hp","Certificates and Declarations/REACH Information":"True - contains substances > 0.1 mass percentage","Technical UL/Output Current, Heavy-Duty Use (UL)":"2.4 A","Technical UL/Output Power, Light-Overload Use (UL)":"0.75 Hp","Technical UL/Output Current, Light-Overload Use (UL)":"3.5 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3axd50000716579","alternativesUrl":"https://aoctrl.com/api/mcp/products/3AXD50000716579/alternatives.json"},"ai":{"faq":[{"question":"What are the key output ratings for this drive?","answer":"Normal use: 0.55 kW at 3.7 A. Heavy-duty use: 0.37 kW at 2.4 A. Light-overload use: 0.55 kW at 3.5 A. UL ratings are 0.75 Hp (normal and light-overload) and 0.5 Hp (heavy-duty)."},{"question":"What compliance documentation is available for this part?","answer":"RoHS compliant per EU Directive 2011/65/EU and amendment 2015/863, with a declaration date of 20250106. REACH compliant (contains substances >0.1% mass percentage). SCIP number: 8df33f0d-6fb9-4799-9075-9031a17c1386."},{"question":"What is the input voltage and phase requirement?","answer":"Single-phase 200-240 VAC, 47-63 Hz."},{"question":"What communication protocol does this drive use?","answer":"MODBUS is the built-in communication protocol. There is no Industrial Ethernet interface on this variant."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AXD50000716579","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AXD50000716579 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}