{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AXD50000747504","brand":"ABB","brandSlug":"abb","productSlug":"3AXD50000747504","canonicalUrl":"https://aoctrl.com/abb/3AXD50000747504","factsUrl":"https://aoctrl.com/api/mcp/products/3AXD50000747504","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACS530 series, 3AXD50000747504 drive, Frame R1, 0.75 kW, 2.6 A, 380-480 V, 3-phase, IP20, active lifecycle.","salesMarkdown":"The ABB 3AXD50000747504 is the ACS530-01-02A7-4 variant, a Frame R1 drive rated for 0.75 kW normal-use output at 2.6 A on a 380-480 V three-phase supply. Standby loss sits at 14 W — worth noting if the cabinet runs warm or the panel has tight thermal budgeting. The 0.75 kW / 2.6 A rating on 380-480 V three-phase matches a standard 1 hp (0.75 kW) induction motor in a 400 V class installation. The IP20 enclosure is open-type, suited for clean indoor panel mounting — not for washdown or dusty environments. Input frequency range of 47.5-63 Hz covers 50/60 Hz grids without issue. Efficiency is IE2 class, which meets the base level for most industrial applications in regions without mandatory IE3 requirements.","metaTitle":"ABB 3AXD50000747504 ACS530-01-02A7-4 Drive, 0.75 kW, 2.6 A","metaDescription":"ABB ACS530-01-02A7-4 drive, 0.75 kW, 2.6 A, 380-480 V, 3-phase, IP20, Frame R1, active production. Sourced to order via RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Frame Size":"R1","Standby Loss":"14 W","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Module","WEEE Category":"5. Small Equipment (No External Dimension More Than 50 cm)","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Temperature Rating":"Maximum 40 °C","Enclosure Type NEMA":"Open Type","Input Voltage (Uin)":"380 ... 480 V","Degree of Protection":"IP20","Apparent Power Output":"1.8 kV·A","Output Power, Normal Use (Pn)":"0.75 kW","Output Current, Normal Use (In)":"2.6 A","Output Power, Light-Overload Use (PlD)":"0.75 kW","Output Current, Light-Overload Use (IlD)":"2.5 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3axd50000747504","alternativesUrl":"https://aoctrl.com/api/mcp/products/3AXD50000747504/alternatives.json"},"ai":{"faq":[{"question":"What is the standby loss of this drive?","answer":"Standby loss is 14 W, which is the power dissipated when the drive is powered but not running a motor."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AXD50000747504","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AXD50000747504 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}