{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AXD50000747535","brand":"ABB","brandSlug":"abb","productSlug":"3AXD50000747535","canonicalUrl":"https://aoctrl.com/abb/3AXD50000747535","factsUrl":"https://aoctrl.com/api/mcp/products/3AXD50000747535","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACS530-01, 2.2 kW VFD, frame size R1, 3-phase 380-480 V, IP20, active production.","salesMarkdown":"The 3AXD50000747535: Output current of 5.6 A normal use (In) and 5.3 A light-overload (IlD) means the drive can sustain 5.6 A continuously and 5.3 A under light overload conditions. Standby loss of 14 W is the idle power draw — relevant for panel heat calculations in a sealed cabinet. Input voltage range 380-480 V, 3-phase, 47.5-63 Hz. Efficiency class IE2.","metaTitle":"ABB 3AXD50000747535 ACS530-01 Drive, 2.2 kW, Frame R1","metaDescription":"ABB ACS530-01-05A7-4 drive, 2.2 kW normal use, 5.6 A output, 380-480 V 3-phase, frame size R1. Active lifecycle, IP20. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Frame Size":"R1","Standby Loss":"14 W","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Module","WEEE Category":"5. Small Equipment (No External Dimension More Than 50 cm)","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Temperature Rating":"Maximum 40 °C","Enclosure Type NEMA":"Open Type","Input Voltage (Uin)":"380 ... 480 V","Degree of Protection":"IP20","Apparent Power Output":"3.9 kV·A","Output Power, Normal Use (Pn)":"2.2 kW","Output Current, Normal Use (In)":"5.6 A","Output Power, Light-Overload Use (PlD)":"2.2 kW","Output Current, Light-Overload Use (IlD)":"5.3 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3axd50000747535","alternativesUrl":"https://aoctrl.com/api/mcp/products/3AXD50000747535/alternatives.json"},"ai":{"faq":[{"question":"What is the frame size of this drive?","answer":"Frame size R1 — the smallest frame in the ACS530 family. Panel cutout and mounting dimensions follow ABB's R1 standard."},{"question":"What is the standby power loss?","answer":"14 W standby loss. This is the power the drive consumes when idle (no motor running). Useful for panel thermal calculations."},{"question":"What is the normal-use output power and current?","answer":"2.2 kW normal-use power (Pn), 5.6 A normal-use output current (In). Light-overload ratings are 2.2 kW (PlD) and 5.3 A (IlD)."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AXD50000747535","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AXD50000747535 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}