{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AXD50000750009","brand":"ABB","brandSlug":"abb","productSlug":"3AXD50000750009","canonicalUrl":"https://aoctrl.com/abb/3AXD50000750009","factsUrl":"https://aoctrl.com/api/mcp/products/3AXD50000750009","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACQ531-01-07A3-4 drive, 3 kW output, 7.2 A, frame size R1, IP20, active lifecycle.","salesMarkdown":"The 3AXD50000750009: The ABB ACQ531-01-07A3-4 is a 3-phase, 380-480 V input drive rated for 3 kW normal-use output at 7.2 A. Standby loss sits at 14 W, so the thermal budget inside a sealed enclosure stays manageable without forced ventilation.","metaTitle":"3AXD50000750009 ABB ACQ531-01-07A3-4 Drive, 3 kW, 7.2 A, Fra","metaDescription":"ABB ACQ531-01-07A3-4 drive, 3 kW output, 7.2 A, frame size R1, IP20, active production. Sourced to order against an RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Frame Size":"R1","Standby Loss":"14 W","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Module","WEEE Category":"5. Small Equipment (No External Dimension More Than 50 cm)","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Temperature Rating":"Maximum 40 °C","Enclosure Type NEMA":"Open Type","Input Voltage (Uin)":"380 ... 480 V","Degree of Protection":"IP20","Apparent Power Output":"5.0 kV·A","Output Power, Normal Use (Pn)":"3 kW","Output Current, Normal Use (In)":"7.2 A","Output Power, Light-Overload Use (PlD)":"3 kW","Output Current, Light-Overload Use (IlD)":"6.8 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3axd50000750009","alternativesUrl":"https://aoctrl.com/api/mcp/products/3AXD50000750009/alternatives.json"},"ai":{"faq":[{"question":"What is the frame size of 3AXD50000750009?","answer":"The frame size is R1, which is the smallest mechanical format in the ACQ531 family, suited for panel-mount installations."},{"question":"What is the standby loss of this drive?","answer":"Standby loss is 14 W, a figure to factor into enclosure thermal calculations when the drive is powered but not running a motor."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AXD50000750009","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AXD50000750009 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}