{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AXD50000750276","brand":"ABB","brandSlug":"abb","productSlug":"3AXD50000750276","canonicalUrl":"https://aoctrl.com/abb/3AXD50000750276","factsUrl":"https://aoctrl.com/api/mcp/products/3AXD50000750276","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACH531-01-04A1-4, LV AC wall-mounted drive for HVAC, Frame R1, 1.5 kW normal use, 4 A output, 380-480 V 3-phase input, IP20.","salesMarkdown":"It delivers 1.5 kW normal-use power at 4 A output current, fed from a 380-480 V three-phase supply. Standby loss is 14 W, and the unit is rated IP20 with a NEMA Open Type enclosure. Mounts as a wall-mounted module. Input frequency range covers 47.5 to 63 Hz, so it handles both 50 Hz and 60 Hz mains without derating. The 40 °C maximum ambient temperature is typical for indoor HVAC plant rooms; if the environment runs hotter, expect derating per the drive's thermal curve. Efficiency is rated IE2, matching standard induction motor applications.","metaTitle":"ABB 3AXD50000750276 HVAC Drive, 1.5 kW, 4 A, Frame R1","metaDescription":"ABB 3AXD50000750276 LV AC wall-mounted drive for HVAC, 1.5 kW normal use, 4 A output, 380-480 V input, IP20, active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Frame Size":"R1","Standby Loss":"14 W","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Module","WEEE Category":"5. Small Equipment (No External Dimension More Than 50 cm)","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Temperature Rating":"Maximum 40 °C","Enclosure Type NEMA":"Open Type","Input Voltage (Uin)":"380 ... 480 V","Degree of Protection":"IP20","Apparent Power Output":"2.8 kV·A","Output Power, Normal Use (Pn)":"1.5 kW","Output Current, Normal Use (In)":"4 A","Output Power, Light-Overload Use (PlD)":"1.5 kW","Output Current, Light-Overload Use (IlD)":"3.8 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3axd50000750276","alternativesUrl":"https://aoctrl.com/api/mcp/products/3AXD50000750276/alternatives.json"},"ai":{"faq":[{"question":"What is the standby loss?","answer":"Standby loss is 14 W. That's the power the drive consumes when the motor is not running but the control electronics remain powered."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AXD50000750276","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AXD50000750276 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}