{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AXD50000814138","brand":"ABB","brandSlug":"abb","productSlug":"3AXD50000814138","canonicalUrl":"https://aoctrl.com/abb/3AXD50000814138","factsUrl":"https://aoctrl.com/api/mcp/products/3AXD50000814138","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACS180 LV AC machinery drive module, 3AXD50000814138, 7.5 kW normal use, 17 A, 380–480 V 3-phase, IP20, R2 frame.","salesMarkdown":"The ABB 3AXD50000814138 is an ACS180-series LV AC machinery drive module rated for 7.5 kW normal use (17 A) and 5.5 kW heavy-duty use (12.6 A) on a 380–480 V three-phase supply. Frame size R2, IP20 enclosure, NEMA Open Type. Standby loss sits at 12 W. ## Duty ratings in practice Heavy-duty (PhD 5.5 kW / IhD 12.6 A) applies for variable-torque or higher-overhead applications — the 12.6 A ceiling is the one to watch when sizing for a 5.5 kW motor on a demanding cycle. R2 frame, module-style mounting. Ambient temperature max 40 °C. IP20 allows panel-mount without additional enclosure in clean indoor environments. Frequency range 47.5–63 Hz covers 50/60 Hz grids globally. Efficiency class IE2.","metaTitle":"ABB 3AXD50000814138 ACS180 drive, 7.5 kW, 17 A","metaDescription":"ABB ACS180 LV AC drive module 3AXD50000814138, 7.5 kW normal use, 17 A, 380-480 V 3-phase, IP20, R2 frame, active production.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"SCIP":"c4c7e908-d15d-4601-993d-bf271f952213 Finland","Frame Size":"R2","Standby Loss":"12 W","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Module","WEEE Category":"5. Small Equipment (No External Dimension More Than 50 cm)","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Temperature Rating":"Maximum 40 °C","Enclosure Type NEMA":"Open Type","Input Voltage (Uin)":"380 ... 480 V","Degree of Protection":"IP20","Apparent Power Output":"12 kV·A","Output Power, Normal Use (Pn)":"7.5 kW","Output Current, Normal Use (In)":"17 A","Output Power, Heavy-Duty Use (PhD)":"5.5 kW","Output Current, Heavy-Duty Use (IhD)":"12.6 A","Output Power, Light-Overload Use (PlD)":"7.5 kW","Output Current, Light-Overload Use (IlD)":"16.2 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3axd50000814138","alternativesUrl":"https://aoctrl.com/api/mcp/products/3AXD50000814138/alternatives.json"},"ai":{"faq":[{"question":"What is the frame size and enclosure type?","answer":"Frame size R2, IP20, NEMA Open Type."},{"question":"What are the normal-use and heavy-duty ratings?","answer":"Normal use: 7.5 kW, 17 A. Heavy-duty use: 5.5 kW, 12.6 A."},{"question":"What is the SCIP number for this drive?","answer":"SCIP: c4c7e908-d15d-4601-993d-bf271f952213 Finland."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AXD50000814138","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AXD50000814138 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}