{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AXD50000814176","brand":"ABB","brandSlug":"abb","productSlug":"3AXD50000814176","canonicalUrl":"https://aoctrl.com/abb/3AXD50000814176","factsUrl":"https://aoctrl.com/api/mcp/products/3AXD50000814176","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACS580 drive module, Frame R2, 380-480 V 3-phase, 7.5 kW / 17.0 A normal use, 5.5 kW / 12.6 A heavy-duty, IP20, MODBUS, IE2.","salesMarkdown":"The ABB 3AXD50000814176 is a drive module in Frame R2, sized for a 7.5 kW motor at 17.0 A under normal-use (light-overload) duty on a 380-480 V three-phase supply. Heavy-duty use drops the rating to 5.5 kW / 12.6 A. The IP20 enclosure means it is intended for panel mounting. Built-in MODBUS RTU on the control board handles the fieldbus link; there is no industrial Ethernet port, so if the line uses PROFINET or EtherNet/IP, an optional fieldbus adapter will be needed. The 2 analog inputs and 1 analog output cover basic speed reference and feedback, while the 4 digital inputs and 2 digital outputs manage start/stop, fault reset, and run status. Power consumption at rated load is 224 W, with a standby loss of 12 W — relevant for panel thermal calculations. Sound level is 62 dB(A), typical for a drive of this frame size. The module includes the control unit; no separate controller board to order. The drive carries three duty ratings. Normal use (light-overload): 7.5 kW / 17.0 A. Heavy-duty use: 5.5 kW / 12.6 A. Light-overload use is listed at 7.5 kW / 16.2 A. The UL ratings follow the same pattern: heavy-duty at 7.5 Hp / 11.0 A, light-overload at 10 Hp / 14.0 A. The IE2 efficiency level means the drive meets the standard for variable-speed drives in the EU; it is not the highest tier (IE3 or IE4), but for many industrial applications IE2 is the baseline. Power factor is 0.98, which keeps line-side reactive current low. Mounting type is module — it bolts into a panel or onto a backplate. Frame R2 is a compact size. Ambient temperature is rated to a maximum of 40 °C, with operating humidity from 5 to 95 % non-condensing. Altitude is rated to 2000 m without derating. The NEMA enclosure type is Open Type, consistent with the IP20 degree of protection. No battery or cell is included, so no periodic battery replacement. WEEE category is 5 (Small Equipment, external dimension under 50 cm).","metaTitle":"ABB 3AXD50000814176 ACS580 drive module, 7.5 kW, 17.0 A, IP2","metaDescription":"ABB ACS580 drive module 3AXD50000814176, 7.5 kW / 17.0 A normal use, 380-480 V 3-phase, IP20, MODBUS, IE2. Current lifecycle status. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"SCIP":"c4c7e908-d15d-4601-993d-bf271f952213 Finland","Altitude":"2000 m","Includes":"Control unit","Frame Size":"R2","Power Factor":"0.98","Sound dB (A)":"62 dB(A)","Standby Loss":"12 W","Analog Inputs":"2","Frequency (f)":"47 ... 63 Hz","Mounting Type":"Module","WEEE Category":"5. Small Equipment (No External Dimension More Than 50 cm)","Analog Outputs":"1","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Temperature Rating":"Maximum 40 °C","Enclosure Type NEMA":"Open Type","Input Voltage (Uin)":"380 ... 480 V","Degree of Protection":"IP20","Apparent Power Output":"12 kV·A","Communication Protocol":"MODBUS","Power Consumption (@Pcons)":"224 W","Operating Humidity (RHamβ)":"5 ... 95","Multiple Battery Information":"No battery / cell included","Number of Digital In/Outputs":"4 / 2","Number of Hardware Interfaces":"Industrial Ethernet 0","Output Power, Normal Use (Pn)":"7.5 kW","Output Current, Normal Use (In)":"17.0 A","Output Power, Heavy-Duty Use (PhD)":"5.5 kW","Output Current, Heavy-Duty Use (IhD)":"12.6 A","Output Power, Light-Overload Use (PlD)":"7.5 kW","Certificates and Declarations/RoHS Date":"20250106","Certificates and Declarations/REACH Date":"20250905","Output Current, Light-Overload Use (IlD)":"16.2 A","Certificates and Declarations/RoHS Information":"Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019","Technical UL/Output Power, Heavy-Duty Use (UL)":"7.5 Hp","Certificates and Declarations/REACH Information":"True - contains substances > 0.1 mass percentage","Technical UL/Output Current, Heavy-Duty Use (UL)":"11.0 A","Technical UL/Output Power, Light-Overload Use (UL)":"10 Hp","Technical UL/Output Current, Light-Overload Use (UL)":"14.0 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3axd50000814176","alternativesUrl":"https://aoctrl.com/api/mcp/products/3AXD50000814176/alternatives.json"},"ai":{"faq":[{"question":"What compliance documentation is available for this drive?","answer":"RoHS compliance follows EU Directive 2011/65/EU and Amendment 2015/863 (declaration date 2025-01-06). REACH information confirms substances above 0.1 mass percentage (declaration date 2025-09-05). The SCIP number is c4c7e908-d15d-4601-993d-bf271f952213 Finland. UL ratings are provided for heavy-duty and light-overload use."},{"question":"What are the key electrical ratings for this drive?","answer":"Input voltage 380-480 V three-phase, 47-63 Hz. Normal-use output 7.5 kW / 17.0 A, heavy-duty 5.5 kW / 12.6 A, light-overload 7.5 kW / 16.2 A. Apparent power output is 12 kV·A. Power consumption at rated load is 224 W, standby loss 12 W."},{"question":"What communication protocol does this drive support?","answer":"Built-in MODBUS RTU. No industrial Ethernet port is included on the control board; an optional fieldbus adapter is required for protocols like PROFINET or EtherNet/IP."},{"question":"What is the environmental rating for this drive?","answer":"IP20 / NEMA Open Type. Maximum ambient temperature 40 °C, operating humidity 5-95 % non-condensing, altitude 2000 m without derating. Sound level 62 dB(A)."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AXD50000814176","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AXD50000814176 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}