{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AXD50000814534","brand":"ABB","brandSlug":"abb","productSlug":"3AXD50000814534","canonicalUrl":"https://aoctrl.com/abb/3AXD50000814534","factsUrl":"https://aoctrl.com/api/mcp/products/3AXD50000814534","rawCanonicalId":null},"summary":{"shortDescription":"ABB, ACS180 series, LV AC machinery drive module, 22 kW, 50.0 A, 400 V, 3-phase, IP20, MODBUS, Frame Size R4.","salesMarkdown":"## Drive module for 22 kW motor loads The ABB 3AXD50000814534 is an ACS180-series LV AC machinery drive module rated for 22 kW normal-use output power at 50.0 A on a 400 V three-phase supply. That 50 A normal-use current handles a standard 22 kW induction motor driving pumps, fans, or conveyors inside a cabinet. Input voltage range is 380 to 480 V at 47 to 63 Hz, so it lands cleanly on European or North American 400 V class mains without a transformer. Heavy-duty and light-overload ratings both sit at 22 kW, with output currents of 45.0 A and 48.0 A respectively. Under UL listing the heavy-duty and light-overload power both come in at 30 Hp at 460 V, drawing 42.0 A. ## I/O and fieldbus for panel integration This module carries 4 digital inputs and 2 digital outputs, plus 2 analog inputs and 1 analog output — enough for basic run/stop, speed reference, and feedback without an expansion card. Communication is via MODBUS over RS-485; there is no onboard Industrial Ethernet, so if the line uses PROFINET or EtherNet/IP, a separate option module goes into the slot. Frame size R4 determines the physical footprint and mounting hole pattern. Standby loss is 38 W, so a small cabinet fan is enough for thermal management at the 40 °C maximum ambient. Sound level is 69 dB(A) — noticeable but not deafening in a machine cell. SCIP number a7e9add0-620e-4316-8bd6-c358d91bc66b is registered for Finland. UL listing covers heavy-duty and light-overload use at 30 Hp, 42.0 A, 460 V.","metaTitle":"3AXD50000814534 ABB ACS180-04N-050A-4 22 kW Drive Module, 50","metaDescription":"ABB ACS180 drive module, 22 kW normal-use, 50.0 A output, 380-480 V input, MODBUS, IP20, current lifecycle stage. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"SCIP":"a7e9add0-620e-4316-8bd6-c358d91bc66b Finland","Altitude":"2000 m","Includes":"Control unit","Frame Size":"R4","Power Factor":"0.98","Sound dB (A)":"69 dB(A)","Standby Loss":"38 W","Analog Inputs":"2","Frequency (f)":"47 ... 63 Hz","Mounting Type":"Module","WEEE Category":"5. Small Equipment (No External Dimension More Than 50 cm)","Analog Outputs":"1","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Temperature Rating":"Maximum 40 °C","Enclosure Type NEMA":"Open Type","Input Voltage (Uin)":"380 ... 480 V","Degree of Protection":"IP20","Apparent Power Output":"35 kV·A","Communication Protocol":"MODBUS","Operating Humidity (RHamβ)":"5 ... 95","Multiple Battery Information":"No battery / cell included","Number of Digital In/Outputs":"4 / 2","Number of Hardware Interfaces":"Industrial Ethernet 0","Output Power, Normal Use (Pn)":"22 kW","Output Current, Normal Use (In)":"50.0 A","Output Power, Heavy-Duty Use (PhD)":"22 kW","Output Current, Heavy-Duty Use (IhD)":"45.0 A","Output Power, Light-Overload Use (PlD)":"22 kW","Certificates and Declarations/RoHS Date":"20250106","Certificates and Declarations/REACH Date":"20250905","Output Current, Light-Overload Use (IlD)":"48.0 A","Certificates and Declarations/RoHS Information":"Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019","Technical UL/Output Power, Heavy-Duty Use (UL)":"30 Hp","Certificates and Declarations/REACH Information":"True - contains substances > 0.1 mass percentage","Technical UL/Output Current, Heavy-Duty Use (UL)":"42.0 A","Technical UL/Output Power, Light-Overload Use (UL)":"30 Hp","Technical UL/Output Current, Light-Overload Use (UL)":"42.0 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3axd50000814534","alternativesUrl":"https://aoctrl.com/api/mcp/products/3AXD50000814534/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for this drive module?","answer":"Normal-use output is 22 kW at 50.0 A on 400 V three-phase. Heavy-duty output is also 22 kW at 45.0 A. Input voltage range is 380 to 480 V, 47 to 63 Hz. UL ratings are 30 Hp at 42.0 A, 460 V for both heavy-duty and light-overload use."},{"question":"What compliance documentation does this drive have?","answer":"RoHS compliant per EU Directive 2011/65/EU and Amendment 2015/863 (compliance date 2025-01-06). REACH declaration confirms substances above 0.1% mass percentage (next declaration 2025-09-05). SCIP number a7e9add0-620e-4316-8bd6-c358d91bc66b registered for Finland. UL listed for 30 Hp, 42.0 A at 460 V."},{"question":"What is the SCIP number and altitude rating?","answer":"SCIP number is a7e9add0-620e-4316-8bd6-c358d91bc66b registered for Finland. Maximum installation altitude is 2000 m without derating."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AXD50000814534","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AXD50000814534 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}