{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AXD50000840359","brand":"ABB","brandSlug":"abb","productSlug":"3AXD50000840359","canonicalUrl":"https://aoctrl.com/abb/3AXD50000840359","factsUrl":"https://aoctrl.com/api/mcp/products/3AXD50000840359","rawCanonicalId":null},"summary":{"shortDescription":"ABB, ACS180 series, LV AC machinery drive module, 3AXD50000840359, 3 kW / 12.2 A normal use, 2.2 kW / 9.3 A heavy-duty, 200-240 V 1-phase input, MODBUS, IP20, frame R2.","salesMarkdown":"It ships as a control unit included, frame size R2, IP20 open type. Normal-use output is 12.2 A (3 kW); heavy-duty pulls back to 9.3 A (2.2 kW) for tougher loads. MODBUS is onboard, so it talks straight to a PLC without an extra gateway card. Normal-use (Pn) 3 kW / 12.2 A is the headline, but the heavy-duty rating (PhD) 2.2 kW / 9.3 A is what you size against for constant-torque or high-starting-duty applications — pump, compressor, conveyor. Light-overload (PlD) matches normal at 3 kW but current is 11.6 A, so the thermal model is slightly different. UL ratings track the same pattern: 3 Hp light-overload, 3 Hp normal, 3 Hp heavy-duty at 9.8 A. Input is single-phase only, 200-240 V, 47-63 Hz — no three-phase feed option on this variant. Four digital inputs, two digital outputs, two analog inputs, one analog output. That's enough for basic start/stop, speed reference, and a run-feedback or fault relay. MODBUS is the only fieldbus — no Industrial Ethernet on this module. If your line needs PROFINET or EtherNet/IP, you're looking at a different variant or an external gateway. ## Power and environment Apparent power output is 4.9 kV·A, power factor 0.98. Power consumption at rated load is 141 W. Sound level 62 dB(A) — noticeable in a quiet panel but not loud for a drive this size. Operating humidity 5-95% RH non-condensing, altitude 2000 m without derating. IP20 open type means it goes in a cabinet, not on the wall.","metaTitle":"ABB 3AXD50000840359 ACS180 Drive Module, 3 kW, 12.2 A","metaDescription":"ABB ACS180 drive module, 3 kW (12.2 A) normal use, 2.2 kW (9.3 A) heavy-duty. 200-240 V 1-phase input, MODBUS, IP20, active production. RFQ for OEM or replacement.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 240V"],"specifications":{"SCIP":"cb233721-9552-452e-85d9-fab6b51eca0b Finland","Altitude":"2000 m","Includes":"Control unit","Frame Size":"R2","Power Factor":"0.98","Sound dB (A)":"62 dB(A)","Analog Inputs":"2","Frequency (f)":"47 ... 63 Hz","Mounting Type":"Module","WEEE Category":"5. Small Equipment (No External Dimension More Than 50 cm)","Analog Outputs":"1","lifecycle_stage":"current","Number of Phases":"1-phase","Enclosure Type NEMA":"Open Type","Input Voltage (Uin)":"200 ... 240 V","Degree of Protection":"IP20","Apparent Power Output":"4.9 kV·A","Communication Protocol":"MODBUS","Power Consumption (@Pcons)":"141 W","Operating Humidity (RHamβ)":"5 ... 95","Multiple Battery Information":"No battery / cell included","Number of Digital In/Outputs":"4 / 2","Number of Hardware Interfaces":"Industrial Ethernet 0","Output Power, Normal Use (Pn)":"3 kW","Output Current, Normal Use (In)":"12.2 A","Output Power, Heavy-Duty Use (PhD)":"2.2 kW","Output Current, Heavy-Duty Use (IhD)":"9.3 A","Output Power, Light-Overload Use (PlD)":"3 kW","Certificates and Declarations/RoHS Date":"20250106","Certificates and Declarations/REACH Date":"20250905","Output Current, Light-Overload Use (IlD)":"11.6 A","Certificates and Declarations/RoHS Information":"Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019","Technical UL/Output Power, Heavy-Duty Use (UL)":"3 Hp","Certificates and Declarations/REACH Information":"True - contains substances > 0.1 mass percentage","Technical UL/Output Current, Heavy-Duty Use (UL)":"9.8 A","Technical UL/Output Power, Light-Overload Use (UL)":"3 Hp","Technical UL/Output Current, Light-Overload Use (UL)":"11.6 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3axd50000840359","alternativesUrl":"https://aoctrl.com/api/mcp/products/3AXD50000840359/alternatives.json"},"ai":{"faq":[{"question":"What are the key output ratings?","answer":"Normal use: 3 kW / 12.2 A. Heavy-duty use: 2.2 kW / 9.3 A. Light-overload use: 3 kW / 11.6 A. UL ratings: 3 Hp at 9.8 A (heavy-duty) and 11.6 A (light-overload)."},{"question":"What communication protocol does it support?","answer":"MODBUS is the onboard protocol. No Industrial Ethernet interfaces."},{"question":"What compliance documentation is available?","answer":"RoHS compliant per EU Directive 2011/65/EU and Amendment 2015/863 (declaration date 20250106). REACH: contains substances >0.1 mass percentage (declaration date 20250905). SCIP number cb233721-9552-452e-85d9-fab6b51eca0b Finland. WEEE category 5."},{"question":"What is the input voltage and phase requirement?","answer":"200-240 V single-phase, 47-63 Hz. No three-phase input on this variant."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AXD50000840359","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AXD50000840359 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}