{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AXD50000956753","brand":"ABB","brandSlug":"abb","productSlug":"3AXD50000956753","canonicalUrl":"https://aoctrl.com/abb/3AXD50000956753","factsUrl":"https://aoctrl.com/api/mcp/products/3AXD50000956753","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACH180 series LV AC micro drive module for HVAC, order code 3AXD50000956753, 11 kW / 15 Hp, 48 A normal use, 200–240 V 3-phase input, IP20, frame size R4.","salesMarkdown":"The ABB 3AXD50000956753 is a frame-size R4 LV AC micro drive for HVAC fan and pump duty. It delivers 11 kW normal-use output (48.0 A) on a 200–240 V three-phase supply, with a heavy-duty rating of 7.5 kW (30.8 A) for constant-torque loads. Light-overload use holds at 11 kW (46.2 A). UL ratings match: 15 Hp normal-use (46.2 A), 10 Hp heavy-duty (32.0 A), and 15 Hp light-overload (46.2 A). The drive includes a control unit, runs on BACnet communication, and is rated IP20 with a NEMA Open Type enclosure. Heavy-duty current (30.8 A) governs constant-torque applications like screw compressors or positive-displacement pumps. The 200–240 V input range covers common North American 208 V and 240 V supplies; frequency acceptance spans 47.5 to 63 Hz, so it handles 50 Hz and 60 Hz grids without reconfiguration. Standby loss sits at 35 W — relevant for continuously powered installations where idle heat adds up. ## Integration notes Mounts as a module — no separate control unit to order. The drive offers 2 analog inputs and 1 analog output for transducer feedback; digital I/O counts 4 inputs and 2 outputs. BACnet is the onboard fieldbus; no industrial Ethernet interface is fitted. Efficiency class IE2, power factor 0.98. Ambient temperature ceiling is 60 °C. Sound pressure level measures 69 dB(A) — typical for a ventilated drive of this power class.","metaTitle":"ABB 3AXD50000956753 ACH180 micro drive, 11 kW, 48 A, 230 V","metaDescription":"ABB ACH180-04S-048A-2 micro drive, 11 kW / 15 Hp, 48 A normal use, 230 V input, IP20, BACnet, IE2, current production.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 240V"],"specifications":{"SCIP":"2fa266a4-ca31-4604-a9f6-9646f8174b5e Finland","Altitude":"2000 m","Includes":"Control unit","Frame Size":"R4","Power Factor":"0.98","Sound dB (A)":"69.00 dB(A)","Standby Loss":"35 W","Analog Inputs":"2","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Module","WEEE Category":"5. Small Equipment (No External Dimension More Than 50 cm)","Analog Outputs":"1","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Temperature Rating":"Maximum 60 °C","Enclosure Type NEMA":"Open Type","Input Voltage (Uin)":"200 ... 240 V","Degree of Protection":"IP20","Apparent Power Output":"19 kV·A","Communication Protocol":"BACNET","Number of Digital In/Outputs":"4 / 2","Number of Hardware Interfaces":"Industrial Ethernet 0","Output Power, Normal Use (Pn)":"11 kW","Output Current, Normal Use (In)":"48.0 A","Output Power, Heavy-Duty Use (PhD)":"7.5 kW","Output Current, Heavy-Duty Use (IhD)":"30.8 A","Output Power, Light-Overload Use (PlD)":"11 kW","Certificates and Declarations/RoHS Date":"20240110","Certificates and Declarations/REACH Date":"20250905","Output Current, Light-Overload Use (IlD)":"46.2 A","Technical UL/Output Power, Normal Use (UL)":"15 Hp","Technical UL/Output Current, Normal Use (UL)":"46.2 A","Certificates and Declarations/RoHS Information":"Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019","Technical UL/Output Power, Heavy-Duty Use (UL)":"10 Hp","Certificates and Declarations/REACH Information":"True - contains substances > 0.1 mass percentage","Technical UL/Output Current, Heavy-Duty Use (UL)":"32.0 A","Technical UL/Output Power, Light-Overload Use (UL)":"15 Hp","Technical UL/Output Current, Light-Overload Use (UL)":"46.2 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3axd50000956753","alternativesUrl":"https://aoctrl.com/api/mcp/products/3AXD50000956753/alternatives.json"},"ai":{"faq":[{"question":"What compliance documentation is available for this drive?","answer":"RoHS compliance follows EU Directive 2011/65/EU (RoHS date 20240110); REACH declaration confirms substances above 0.1 mass percentage (REACH date 20250905). The SCIP number is 2fa266a4-ca31-4604-a9f6-9646f8174b5e Finland. UL ratings are provided for normal, heavy-duty, and light-overload use."},{"question":"What is the altitude rating for this drive?","answer":"The drive is rated for installation at altitudes up to 2000 m without derating."},{"question":"What is the closest alternative in the ACH180 family?","answer":"Within the ACH180 series, the closest sibling is the next-lower current variant (R3 frame, lower output current). The R4 frame here is the 48 A normal-use version; stepping down reduces both frame size and current rating. No pin-compatible drop-in exists — frame and power level differ."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AXD50000956753","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AXD50000956753 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}