{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AXD50001002817","brand":"ABB","brandSlug":"abb","productSlug":"3AXD50001002817","canonicalUrl":"https://aoctrl.com/abb/3AXD50001002817","factsUrl":"https://aoctrl.com/api/mcp/products/3AXD50001002817","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACQ580-01 wall-mounted drive, 3AXD50001002817, 1.1 kW normal use, 6.7 A, 200-240 V, IP66/NEMA 4X, frame R1.","salesMarkdown":"The 3AXD50001002817: Normal-use output is 1.1 kW / 6.7 A; heavy-duty drops to 0.75 kW / 4.6 A. Light-overload stays at 1.1 kW / 6.6 A, which matches the UL 1.5 Hp rating. If your load profile cycles hard, size on the heavy-duty figure. Standby loss is 13 W — negligible for a continuously powered panel, but worth noting for battery-backed installations. Power factor 0.98 at rated load. ## I/O and comms at a glance Two analog inputs, two analog outputs. Six digital inputs, three digital outputs. Communication is CAN — no onboard Ethernet, so plan for a gateway if your control network is PROFINET or EtherNet/IP. The CR2032 lithium coin keeps the real-time clock alive; it's a standard cell, easy to replace during annual PM.","metaTitle":"ABB 3AXD50001002817 ACQ580-01 Drive, 1.1 kW, IP66","metaDescription":"ABB ACQ580-01 wall-mounted drive, 1.1 kW normal use, 6.7 A, 200-240 V, IP66/NEMA 4X. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 240V"],"specifications":{"Includes":"Control unit","Frame Size":"R1","Power Factor":"0.98","Standby Loss":"13 W","Analog Inputs":"2","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Wall-mounted","Analog Outputs":"2","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Temperature Rating":"Maximum 40 °C","Enclosure Type NEMA":"Type4X","Input Voltage (Uin)":"200 ... 240 V","Degree of Protection":"IP66","Apparent Power Output":"2.7 kV·A","Communication Protocol":"CAN","Multiple Battery Information":"Lithium Coin; CR2032; 220 mAh; 3 V; 1 pc; 3 g","Number of Digital In/Outputs":"6 / 3","Number of Hardware Interfaces":"Industrial Ethernet 0","Output Power, Normal Use (Pn)":"1.1 kW","Output Current, Normal Use (In)":"6.7 A","Output Power, Heavy-Duty Use (PhD)":"0.75 kW","Output Current, Heavy-Duty Use (IhD)":"4.6 A","Output Power, Light-Overload Use (PlD)":"1.1 kW","Output Current, Light-Overload Use (IlD)":"6.6 A","Technical UL/Output Power, Light-Overload Use (UL)":"1.5 Hp","Technical UL/Output Current, Light-Overload Use (UL)":"6.6 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3axd50001002817","alternativesUrl":"https://aoctrl.com/api/mcp/products/3AXD50001002817/alternatives.json"},"ai":{"faq":[{"question":"What is the frame size and enclosure rating?","answer":"Frame R1, IP66, NEMA Type 4X. Suitable for wall mounting in washdown or outdoor enclosures."},{"question":"What are the key electrical ratings?","answer":"Normal use: 1.1 kW, 6.7 A. Heavy-duty: 0.75 kW, 4.6 A. Input 200-240 V three-phase, 47.5-63 Hz."},{"question":"What communication protocol does it support?","answer":"CAN. No industrial Ethernet interface on this variant."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AXD50001002817","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AXD50001002817 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}