{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AXD50001002824","brand":"ABB","brandSlug":"abb","productSlug":"3AXD50001002824","canonicalUrl":"https://aoctrl.com/abb/3AXD50001002824","factsUrl":"https://aoctrl.com/api/mcp/products/3AXD50001002824","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACQ580-01 wall-mounted drive, 3AXD50001002824, 1.5 kW / 7.6 A normal use, 200-240 V 3-phase, IP66, NEMA 4X, frame size R1, includes control unit.","salesMarkdown":"## Drive selection memo — ABB ACQ580-01, 1.5 kW, IP66 The ABB 3AXD50001002824 is an ACQ580-01 wall-mounted drive sized for a 1.5 kW motor on 200-240 V three-phase supply, delivering 7.6 A in normal use. It's built for water and wastewater duty — the IP66 / NEMA 4X enclosure means it handles washdown environments without an extra cabinet. ## Rating so-what — normal vs heavy-duty curves Three output ratings let you match the drive to the load profile. Normal-use (Pn) is 1.5 kW at 7.6 A — that's the continuous rating for a centrifugal pump or fan. Heavy-duty (PhD) drops to 1.1 kW at 6.6 A, which covers constant-torque loads like a screw conveyor or positive-displacement pump where you need peak torque at low speed. Light-overload (PlD) matches normal at 1.5 kW but at 7.5 A, a slight current derating that matters for UL-listed installations where the 2 Hp / 7.5 A line applies. ## I/O and communication — what's on board The drive carries 6 digital inputs and 3 digital outputs, plus 2 analog inputs and 2 analog outputs — enough for basic pump control (level transmitter, start/stop, run status) without an expansion module. Communication is CAN-based; there's no onboard Ethernet port, so if you need remote monitoring over a plant network, plan for a fieldbus adapter or a gateway. The standby loss is 13 W, and the power factor is 0.98 at rated load — the input harmonics are low enough that you can skip a line reactor on most utility feeds.","metaTitle":"ABB 3AXD50001002824 ACQ580-01 Drive, 1.5 kW, IP66, NEMA 4X","metaDescription":"ABB ACQ580-01 drive 3AXD50001002824, 1.5 kW normal use, 7.6 A, 200-240 V, IP66/NEMA 4X. Active production. Quoted to order. Includes control unit, frame R1.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 240V"],"specifications":{"Includes":"Control unit","Frame Size":"R1","Power Factor":"0.98","Standby Loss":"13 W","Analog Inputs":"2","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Wall-mounted","Analog Outputs":"2","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Temperature Rating":"Maximum 40 °C","Enclosure Type NEMA":"Type4X","Input Voltage (Uin)":"200 ... 240 V","Degree of Protection":"IP66","Apparent Power Output":"3.0 kV·A","Communication Protocol":"CAN","Multiple Battery Information":"Lithium Coin; CR2032; 220 mAh; 3 V; 1 pc; 3 g","Number of Digital In/Outputs":"6 / 3","Number of Hardware Interfaces":"Industrial Ethernet 0","Output Power, Normal Use (Pn)":"1.5 kW","Output Current, Normal Use (In)":"7.6 A","Output Power, Heavy-Duty Use (PhD)":"1.1 kW","Output Current, Heavy-Duty Use (IhD)":"6.6 A","Output Power, Light-Overload Use (PlD)":"1.5 kW","Output Current, Light-Overload Use (IlD)":"7.5 A","Technical UL/Output Power, Light-Overload Use (UL)":"2 Hp","Technical UL/Output Current, Light-Overload Use (UL)":"7.5 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3axd50001002824","alternativesUrl":"https://aoctrl.com/api/mcp/products/3AXD50001002824/alternatives.json"},"ai":{"faq":[{"question":"What is the IP rating and enclosure type for this drive?","answer":"The drive is rated IP66 with a NEMA Type 4X enclosure, meaning it's dust-tight and protected against powerful water jets, suitable for outdoor or washdown installations without an additional cabinet."},{"question":"What are the normal-use and heavy-duty output ratings?","answer":"Normal-use output is 1.5 kW at 7.6 A; heavy-duty output is 1.1 kW at 6.6 A. Both are on a 200-240 V three-phase supply."},{"question":"Where can I buy 3AXD50001002824 and how is it quoted?","answer":"This drive is sourced to order through independent distribution. Submit an RFQ for current availability and pricing — figures are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AXD50001002824","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AXD50001002824 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}