{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AXD50001003029","brand":"ABB","brandSlug":"abb","productSlug":"3AXD50001003029","canonicalUrl":"https://aoctrl.com/abb/3AXD50001003029","factsUrl":"https://aoctrl.com/api/mcp/products/3AXD50001003029","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACS580-01 series, wall-mounted LV AC drive, 1.5 kW / 2 Hp, 7.6 A, IP66, NEMA Type 4X, frame size R1.","salesMarkdown":"The 3AXD50001003029: The drive carries both IEC and UL ratings: 1.5 kW / 7.6 A under IEC normal use, and 2 Hp / 7.5 A under UL light-overload duty. ## Mounting and enclosure — where it fits Wall-mounted in an IP66 / NEMA Type 4X enclosure, frame size R1. That means it is rated for hose-down environments, outdoor installation under cover, and dusty or corrosive washdown areas — food processing, car washes, chemical dosing skids. The R1 frame keeps the footprint compact for a 1.5 kW drive at this protection level, but plan for the gland plate entry: incoming power and motor cables need to land through the bottom conduit openings, and the IP66 seal must be maintained after wiring. Ambient temperature is capped at 40 °C maximum. If the panel or enclosure sees higher ambient — summer roofline, sun-loaded wall — derate the output current or add forced ventilation. The standby loss of 13 W is modest and won't drive internal heating on its own, but it adds to whatever else shares the enclosure. ## Control and communication Two analog inputs and two analog outputs are onboard for speed reference, feedback, or process-variable retransmission. Six digital inputs and three digital outputs handle start/stop, fault reset, and status indication. The communication interface is CAN — no onboard Ethernet, so if the line uses PROFINET or EtherNet/IP, an optional fieldbus adapter module is needed. The control unit includes a real-time clock backed by a CR2032 lithium coin cell (220 mAh, 3 V). That keeps the time-stamped fault log and run-time counters alive through power cycles. The cell is replaceable; factor a spare into the MRO kit if the drive is in a hard-to-access location. ## Efficiency and power quality Rated IE2 efficiency level with a power factor of 0.98. That is the drive-side input power factor — near-unity, so no external power-factor correction is needed for the drive itself. The 13 W standby loss is the control electronics draw when the motor is not running; it is not the full no-load input power, which will be higher due to the DC bus precharge and fan.","metaTitle":"ABB 3AXD50001003029 ACS580-01 Drive, 1.5 kW, IP66","metaDescription":"ABB ACS580-01-07A6-2+B063 wall-mounted drive, 1.5 kW normal use, 7.6 A, IP66, NEMA 4X. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 240V"],"specifications":{"Includes":"Control unit","Frame Size":"R1","Power Factor":"0.98","Standby Loss":"13 W","Analog Inputs":"2","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Wall-mounted","Analog Outputs":"2","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Temperature Rating":"Maximum 40 °C","Enclosure Type NEMA":"Type4X","Input Voltage (Uin)":"200 ... 240 V","Degree of Protection":"IP66","Apparent Power Output":"3.0 kV·A","Communication Protocol":"CAN","Multiple Battery Information":"Lithium Coin; CR2032; 220 mAh; 3 V; 1 pc; 3 g","Number of Digital In/Outputs":"6 / 3","Number of Hardware Interfaces":"Industrial Ethernet 0","Output Power, Normal Use (Pn)":"1.5 kW","Output Current, Normal Use (In)":"7.6 A","Output Power, Heavy-Duty Use (PhD)":"1.1 kW","Output Current, Heavy-Duty Use (IhD)":"6.6 A","Output Power, Light-Overload Use (PlD)":"1.5 kW","Output Current, Light-Overload Use (IlD)":"7.5 A","Technical UL/Output Power, Light-Overload Use (UL)":"2 Hp","Technical UL/Output Current, Light-Overload Use (UL)":"7.5 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3axd50001003029","alternativesUrl":"https://aoctrl.com/api/mcp/products/3AXD50001003029/alternatives.json"},"ai":{"faq":[{"question":"What is included with the 3AXD50001003029?","answer":"The order code includes the control unit as part of the drive assembly. It is a complete wall-mounted drive, not a bare power stage."},{"question":"What is the frame size and enclosure rating?","answer":"Frame size R1, IP66 / NEMA Type 4X enclosure, wall-mounted. Suitable for washdown and outdoor sheltered installation."},{"question":"What are the key power ratings for this drive?","answer":"IEC normal use: 1.5 kW / 7.6 A. UL light-overload: 2 Hp / 7.5 A. Heavy-duty: 1.1 kW / 6.6 A. Input voltage 200–240 V three-phase."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AXD50001003029","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AXD50001003029 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}