{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AXD50001003111","brand":"ABB","brandSlug":"abb","productSlug":"3AXD50001003111","canonicalUrl":"https://aoctrl.com/abb/3AXD50001003111","factsUrl":"https://aoctrl.com/api/mcp/products/3AXD50001003111","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACS580-01 series, LV AC industrial wall-mounted single drive, 2.2 kW / 5.6 A, 400 V, IP66, NEMA 4X, frame size R1, includes control unit.","salesMarkdown":"The ABB 3AXD50001003111 is a wall-mounted drive rated for 2.2 kW normal-use output at 5.6 A on a 380–415 V three-phase supply. It ships with the control unit included. Frame size R1 keeps the footprint compact for panel or wall mounting, and the IP66 / NEMA 4X enclosure means it can sit directly on the machine or in a washdown area without an extra cabinet. Ambient limit is 40 °C, so watch the air flow if you pack several in a row. The drive carries IE2 efficiency and a power factor of 0.98, which keeps the line-side losses low for continuous-duty applications. Standby loss sits at 14 W — not negligible if the drive stays powered but idle for long periods. Normal-use output (Pn) is 2.2 kW at 5.6 A — that's the rating for typical constant-torque loads like conveyors or fans running within the drive's continuous current capability. Heavy-duty use (PhD) drops to 1.5 kW at 4 A, which is the headroom you need for high-starting-torque applications or overload cycles. Light-overload use (PlD) stays at 2.2 kW but at 5.3 A, slightly below the normal-use current, reflecting a different duty cycle definition. Under UL listing, the light-overload output is 3 Hp at 4.8 A — close to the IEC light-overload figure but not identical, so match the rating system your local code requires. Apparent power output is 3.9 kV·A. Frequency range is 47.5 to 63 Hz. ## I/O and communication — what's on board The control unit provides 2 analog inputs, 2 analog outputs, and 6 digital inputs plus 3 digital outputs. That's enough for basic speed reference, feedback, and start/stop logic without an expansion module. Communication is CAN-based — no onboard Industrial Ethernet, so if you need PROFINET or EtherNet/IP, plan for an optional fieldbus adapter. A CR2032 lithium coin cell (220 mAh, 3 V) backs the real-time clock and parameter storage. It's a standard cell, easy to replace during maintenance.","metaTitle":"ABB 3AXD50001003111 ACS580-01 VFD, 2.2 kW, IP66","metaDescription":"ABB 3AXD50001003111 ACS580-01 drive, 2.2 kW / 5.6 A, IP66/NEMA 4X, frame R1, active production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Includes":"Control unit","Frame Size":"R1","Power Factor":"0.98","Standby Loss":"14 W","Analog Inputs":"2","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Wall-mounted","Analog Outputs":"2","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Temperature Rating":"Maximum 40 °C","Enclosure Type NEMA":"Type4X","Input Voltage (Uin)":"380 ... 415 V","Degree of Protection":"IP66","Apparent Power Output":"3.9 kV·A","Communication Protocol":"CAN","Multiple Battery Information":"Lithium Coin; CR2032; 220 mAh; 3 V; 1 pc; 3 g","Number of Digital In/Outputs":"6 / 3","Number of Hardware Interfaces":"Industrial Ethernet 0","Output Power, Normal Use (Pn)":"2.2 kW","Output Current, Normal Use (In)":"5.6 A","Output Power, Heavy-Duty Use (PhD)":"1.5 kW","Output Current, Heavy-Duty Use (IhD)":"4 A","Output Power, Light-Overload Use (PlD)":"2.2 kW","Output Current, Light-Overload Use (IlD)":"5.3 A","Technical UL/Output Power, Light-Overload Use (UL)":"3 Hp","Technical UL/Output Current, Light-Overload Use (UL)":"4.8 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3axd50001003111","alternativesUrl":"https://aoctrl.com/api/mcp/products/3AXD50001003111/alternatives.json"},"ai":{"faq":[{"question":"What is the frame size of this drive?","answer":"Frame size R1, which is the smallest frame in the ACS580-01 series, suitable for wall mounting."},{"question":"Does the drive include a control unit?","answer":"Yes, the control unit is included with the 3AXD50001003111 order code. No separate purchase is needed for basic I/O and CAN communication."},{"question":"What enclosure rating does it have?","answer":"IP66 and NEMA 4X, suitable for washdown environments and outdoor installation without an additional cabinet."},{"question":"What are the key output ratings?","answer":"Normal-use: 2.2 kW at 5.6 A. Heavy-duty: 1.5 kW at 4 A. Light-overload: 2.2 kW at 5.3 A (IEC) or 3 Hp at 4.8 A (UL)."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AXD50001003111","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AXD50001003111 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}