{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AXD50001057442","brand":"ABB","brandSlug":"abb","productSlug":"3AXD50001057442","canonicalUrl":"https://aoctrl.com/abb/3AXD50001057442","factsUrl":"https://aoctrl.com/api/mcp/products/3AXD50001057442","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACS880-17, 3AXD50001057442, 400 kW normal-use output at 730 A, heavy-duty 250 kW / 546 A, 380-415 V 3-phase, Frame R8i+R8i, IP22, NEMA 1.","salesMarkdown":"## Duty ratings that matter The 3AXD50001057442: Three duty ratings let you size the drive to the load profile. Normal use (Pn 400 kW, In 730 A) covers constant-torque applications like conveyors or pumps running at full speed. Heavy-duty use (PhD 250 kW, IhD 546 A) handles higher peak torque demands — think crushers or extruders that need that extra grunt on startup. Pick the rating that matches your motor nameplate and duty cycle; the drive's internal thermal model will protect it. ## What's inside the frame The R8i+R8i frame houses two lithium coin cells (BR2032, 3 V, 200 mAh each) likely for real-time clock backup or parameter retention. Operating humidity range is 5 to 95 % RH, non-condensing — typical for a drive in a climate-controlled electrical room. No UL horsepower or current ratings are listed for this variant (– show dashes), so if UL listing is a spec gate, confirm with the factory before committing.","metaTitle":"ABB 3AXD50001057442 ACS880-17 Drive, 400 kW, 730 A","metaDescription":"ABB 3AXD50001057442 ACS880-17 drive, 400 kW normal-use output at 730 A. Heavy-duty rated 250 kW / 546 A. Active production. Frame R8i+R8i, 380-415 V 3-phase input, IP22, NEMA 1. So","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Frame Size":"R8i+R8i","Frequency (f)":"48 ... 63 Hz","WEEE Category":"4. Large Equipment (Any External Dimension More Than 50 cm)","lifecycle_stage":"current","Number of Phases":"3-phase","Enclosure Type NEMA":"Type1","Input Voltage (Uin)":"380 ... 415 V","Degree of Protection":"IP22","Operating Humidity (RHamβ)":"5 ... 95","Multiple Battery Information":"Lithium Coin, BR2032, 2pcs, 3V, 200mAh, 3g","Output Power, Normal Use (Pn)":"400 kW","Output Current, Normal Use (In)":"730 A","Output Power, Heavy-Duty Use (PhD)":"250 kW","Output Current, Heavy-Duty Use (IhD)":"546 A","Output Power, Light-Overload Use (PlD)":"355 kW","Output Current, Light-Overload Use (IlD)":"701 A","Technical UL/Output Power, Heavy-Duty Use (UL)":"- Hp","Technical UL/Output Current, Heavy-Duty Use (UL)":"- A","Technical UL/Output Power, Light-Overload Use (UL)":"- Hp","Technical UL/Output Current, Light-Overload Use (UL)":"- A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3axd50001057442","alternativesUrl":"https://aoctrl.com/api/mcp/products/3AXD50001057442/alternatives.json"},"ai":{"faq":[{"question":"What are the key power ratings for this drive?","answer":"Normal-use output is 400 kW at 730 A. Heavy-duty use is 250 kW at 546 A. Light-overload use is 355 kW at 701 A."},{"question":"What is the frame size of this drive?","answer":"Frame size is R8i+R8i, a large cabinet-style enclosure rated IP22 and NEMA Type 1."},{"question":"What input voltage and frequency does it accept?","answer":"Input voltage is 380 to 415 V AC, 3-phase, at 48 to 63 Hz."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AXD50001057442","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AXD50001057442 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}