{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AXD50001062606","brand":"ABB","brandSlug":"abb","productSlug":"3AXD50001062606","canonicalUrl":"https://aoctrl.com/abb/3AXD50001062606","factsUrl":"https://aoctrl.com/api/mcp/products/3AXD50001062606","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACS580-01-089A-4, LV AC general-purpose wall-mounted drive, 45 kW / 89 A normal duty, 380–480 V 3-phase, IP21, R4 frame.","salesMarkdown":"The ABB 3AXD50001062606 is the order code for an ACS580-01-089A-4 wall-mounted general-purpose drive. Input accepts 380–480 V 3-phase, 47.5–63 Hz. Frame size R4, IP21, NEMA Type 1 enclosure — suitable for indoor panel or wall mounting without additional filtration in clean environments. ## Output ratings and duty cycles Three duty ratings are listed: light-overload use at 45 kW / 83 A, normal use at 45 kW / 89 A, and heavy-duty use at 37 kW / 72 A. The heavy-duty figure governs constant-torque applications; the normal-use current (89 A) is the one to match against motor FLA for variable-torque loads like pumps and fans. Apparent power output is 62 kV·A at the rated voltage. ## Efficiency and losses Efficiency Level IE2, with standby loss of 21 W and power consumption at rated output of 1028 W. The standby figure matters for panel heat-budget calculations — 21 W continuous keeps the enclosure rise modest, but the full-load dissipation pushes 1 kW, so forced ventilation is worth planning for in a sealed cabinet. Includes a control unit with 2 analog inputs, 2 analog outputs, 6 digital inputs, and 3 digital outputs. Communication is CAN-based — no onboard Industrial Ethernet. For PROFINET or EtherNet/IP, you would add an optional fieldbus adapter module. The lithium coin cell (CR2032, 220 mAh) backs the real-time clock and parameter storage.","metaTitle":"3AXD50001062606 ABB ACS580-01-089A-4 45 kW Drive, 89 A, IP21","metaDescription":"ABB ACS580-01-089A-4 general-purpose drive, 45 kW normal duty, 89 A output, IP21 wall-mount, Type 1, R4 frame. Active production. RFQ for pricing.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"SCIP":"5f7a2ba9-ac26-45aa-b6b8-92237e07b94f Finland","Altitude":"4000 m","Includes":"Control unit","Frame Size":"R4","Sound dB (A)":"70 dB(A)","Standby Loss":"21 W","Analog Inputs":"2","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Wall-mounted","WEEE Category":"4. Large Equipment (Any External Dimension More Than 50 cm)","Analog Outputs":"2","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Temperature Rating":"Maximum 40 °C","Enclosure Type NEMA":"Type1","Input Voltage (Uin)":"380 ... 480 V","Degree of Protection":"IP21","Apparent Power Output":"62 kV·A","Communication Protocol":"CAN","Power Consumption (@Pcons)":"1028 W","Operating Humidity (RHamβ)":"5 ... 95","Multiple Battery Information":"Lithium Coin, CR2032, 220 mAh, 3 V, 1 pc, 3 g","Number of Digital In/Outputs":"6 / 3","Number of Hardware Interfaces":"Industrial Ethernet 0","Output Power, Normal Use (Pn)":"45 kW","Output Current, Normal Use (In)":"89 A","Output Power, Heavy-Duty Use (PhD)":"37 kW","Output Current, Heavy-Duty Use (IhD)":"72 A","Output Power, Light-Overload Use (PlD)":"45 kW","Certificates and Declarations/RoHS Date":"20240508","Certificates and Declarations/REACH Date":"20250905","Output Current, Light-Overload Use (IlD)":"83 A","Certificates and Declarations/RoHS Information":"Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019","Certificates and Declarations/REACH Information":"True - contains substances > 0.1 mass percentage"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3axd50001062606","alternativesUrl":"https://aoctrl.com/api/mcp/products/3AXD50001062606/alternatives.json"},"ai":{"faq":[{"question":"What are the key output ratings for this drive?","answer":"Normal-duty output is 45 kW at 89 A; heavy-duty output is 37 kW at 72 A; light-overload output is 45 kW at 83 A. Apparent power output is 62 kV·A."},{"question":"What is the enclosure rating and mounting style?","answer":"IP21, NEMA Type 1, wall-mounted. Frame size R4."},{"question":"What communication protocol does this drive use?","answer":"CAN protocol. No onboard Industrial Ethernet; a fieldbus adapter is required for PROFINET or EtherNet/IP."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AXD50001062606","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AXD50001062606 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}