{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AXD50001063115","brand":"ABB","brandSlug":"abb","productSlug":"3AXD50001063115","canonicalUrl":"https://aoctrl.com/abb/3AXD50001063115","factsUrl":"https://aoctrl.com/api/mcp/products/3AXD50001063115","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACS580-01 wall-mounted LV AC drive, 3AXD50001063115, 45 kW / 89 A normal use, IP55, frame R4, CAN interface.","salesMarkdown":"The ABB 3AXD50001063115 is an ACS580-01 wall-mounted LV AC general-purpose drive rated for 45 kW normal-use output at 89 A on 400 V three-phase supply. Light-overload use matches the normal-use power at 45 kW but with a slightly lower 83 A output current — useful for variable-torque pump/fan profiles where the drive runs below full load most of the cycle. Input voltage range is 380–480 V three-phase at 47.5–63 Hz, which covers standard 400 V and 480 V industrial mains without a transformer. Standby loss is 21 W — low enough that a panel can leave the drive powered without meaningful heat buildup during idle shifts. The IP55 enclosure and NEMA Type12 rating mean the drive handles washdown splashes and airborne dust in food-and-bev or woodworking environments without an additional cabinet. Mount it directly on the wall or machine frame; frame size R4 keeps the footprint manageable for a 45 kW class unit. The drive carries 2 analog inputs and 2 analog outputs for speed reference or process feedback loops, plus 6 digital inputs and 3 digital outputs for start/stop, fault reset, and status indication. No onboard industrial Ethernet port — communication is via CAN protocol, so plan for a CANopen master or gateway if the line uses PROFINET or EtherNet/IP. The control unit is included in the package — no separate order needed for basic operation. A lithium coin cell (CR2032, 220 mAh) backs up real-time clock and parameter storage; verify replacement interval against the site's PM schedule. SCIP number 9ca40e89-23b4-4f19-bc9a-b7c6f62cb713 Finland is on file for SVHC reporting. Altitude rating is 4000 m — no derating needed for most high-altitude installations, though the IP55 seal may need a check above 3000 m if the site sees rapid pressure changes.","metaTitle":"ABB 3AXD50001063115 ACS580-01 Drive, 45 kW, 89 A, IP55","metaDescription":"ABB 3AXD50001063115 ACS580-01 wall-mounted drive, 45 kW normal use, 89 A, IP55, active production. Sourced to order against RFQ. RoHS/REACH compliant.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"SCIP":"9ca40e89-23b4-4f19-bc9a-b7c6f62cb713 Finland","Altitude":"4000 m","Includes":"Control unit","Frame Size":"R4","Sound dB (A)":"70 dB(A)","Standby Loss":"21 W","Analog Inputs":"2","Frequency (f)":"47.5 ... 63 Hz","WEEE Category":"4. Large Equipment (Any External Dimension More Than 50 cm)","Analog Outputs":"2","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Enclosure Type NEMA":"Type12","Input Voltage (Uin)":"380 ... 480 V","Degree of Protection":"IP55","Apparent Power Output":"62 kV·A","Communication Protocol":"CAN","Power Consumption (@Pcons)":"1028 W","Multiple Battery Information":"Lithium Coin, CR2032, 220 mAh, 3 V, 1 pc, 3 g","Number of Digital In/Outputs":"6 / 3","Number of Hardware Interfaces":"Industrial Ethernet 0","Output Power, Normal Use (Pn)":"45 kW","Output Current, Normal Use (In)":"89 A","Output Power, Heavy-Duty Use (PhD)":"37 kW","Output Current, Heavy-Duty Use (IhD)":"72 A","Output Power, Light-Overload Use (PlD)":"45 kW","Certificates and Declarations/RoHS Date":"20240508","Certificates and Declarations/REACH Date":"20250905","Output Current, Light-Overload Use (IlD)":"83 A","Certificates and Declarations/RoHS Information":"Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019","Certificates and Declarations/REACH Information":"True - contains substances > 0.1 mass percentage"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3axd50001063115","alternativesUrl":"https://aoctrl.com/api/mcp/products/3AXD50001063115/alternatives.json"},"ai":{"faq":[{"question":"What are the normal-use and heavy-duty output ratings for this drive?","answer":"Normal-use output is 45 kW at 89 A; heavy-duty use is 37 kW at 72 A. Light-overload use matches normal-use power at 45 kW but at 83 A output current."},{"question":"What enclosure protection does 3AXD50001063115 have?","answer":"IP55 and NEMA Type12 — suitable for washdown environments and dusty industrial floors without an additional cabinet."},{"question":"What communication protocol does this drive use?","answer":"CAN protocol is the onboard interface. There is no industrial Ethernet port, so plan for a CANopen master or gateway for higher-level fieldbus integration."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AXD50001063115","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AXD50001063115 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}