{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AXD50001109448","brand":"ABB","brandSlug":"abb","productSlug":"3AXD50001109448","canonicalUrl":"https://aoctrl.com/abb/3AXD50001109448","factsUrl":"https://aoctrl.com/api/mcp/products/3AXD50001109448","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACQ580-01 LV AC wall-mounted drive, 3-phase 200-240 V, normal-use 3 kW / 12 A, IP66/NEMA 4X, CAN, 2 analog inputs, 2 analog outputs.","salesMarkdown":"## Drive ratings and enclosure for water/wastewater duty The 3AXD50001109448: Enclosure is IP66 / NEMA 4X, rated for a maximum 40 °C ambient. That makes it a straight fit for washdown or outdoor installations without a separate cabinet — common in water and wastewater applications. ## Active production — no lifecycle concern Status is active per the manufacturer.","metaTitle":"ABB 3AXD50001109448 ACQ580 Drive, 3 kW, 12 A, 230 V","metaDescription":"Active ABB ACQ580-01 wall-mounted drive, 3 kW / 12 A normal use, IP66/NEMA 4X, CAN, 2 analog I/O. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 240V"],"specifications":{"Includes":"Control unit","Power Factor":"0.98","Standby Loss":"13 W","Analog Inputs":"2","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Wall-mounted","Analog Outputs":"2","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Temperature Rating":"Maximum 40 °C","Enclosure Type NEMA":"Type4X","Input Voltage (Uin)":"200 ... 240 V","Degree of Protection":"IP66","Apparent Power Output":"4.8 kV·A","Communication Protocol":"CAN","Multiple Battery Information":"Lithium Coin; CR2032; 220 mAh; 3 V; 1 pc; 3 g","Number of Digital In/Outputs":"6 / 3","Number of Hardware Interfaces":"Industrial Ethernet 0","Output Power, Normal Use (Pn)":"3 kW","Output Current, Normal Use (In)":"12 A","Output Power, Heavy-Duty Use (PhD)":"2.2 kW","Output Current, Heavy-Duty Use (IhD)":"7.5 A","Output Power, Light-Overload Use (PlD)":"3 kW","Output Current, Light-Overload Use (IlD)":"11.8 A","Technical UL/Output Power, Light-Overload Use (UL)":"3 Hp","Technical UL/Output Current, Light-Overload Use (UL)":"10.6 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3axd50001109448","alternativesUrl":"https://aoctrl.com/api/mcp/products/3AXD50001109448/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for this drive?","answer":"Normal-use output is 3 kW / 12 A at 200–240 V three-phase. Heavy-duty is 2.2 kW / 7.5 A. UL light-overload is 3 Hp / 10.6 A. Enclosure is IP66/NEMA 4X."},{"question":"What communication protocol does this drive support?","answer":"CAN. There is no onboard industrial Ethernet interface."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AXD50001109448","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AXD50001109448 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}