{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AXD50001109479","brand":"ABB","brandSlug":"abb","productSlug":"3AXD50001109479","canonicalUrl":"https://aoctrl.com/abb/3AXD50001109479","factsUrl":"https://aoctrl.com/api/mcp/products/3AXD50001109479","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACQ580-01 series, LV AC wall-mounted drive for water and wastewater, IEC: Pn 7.5 kW, 31.2 A, 230 V, UL: Pld 10 Hp, 31 A, 230 V, IP66, NEMA Type 4X.","salesMarkdown":"The ABB 3AXD50001109479 is an ACQ580-01 series wall-mounted LV AC drive purpose-built for water and wastewater duty. It delivers 7.5 kW (31.2 A) under IEC normal-use rating and 10 Hp (31 A) under UL light-overload use, fed from a 200-240 V three-phase supply. The unit ships with the control unit included. The normal-use output current of 31.2 A (Pn 7.5 kW) covers continuous pump and fan duty. Heavy-duty use is rated 24.2 A (5.5 kW) for higher-torque loads like screw pumps or conveyors. Light-overload use at 30.8 A (7.5 kW) aligns with the UL 10 Hp rating, giving the same headroom for variable-torque applications. The 0.98 power factor and IE2 efficiency level mean the drive draws near-unity power from the line, reducing upstream cable and transformer sizing. ## Environmental sealing and mounting IP66 and NEMA Type 4X enclosure means the drive handles washdown environments, dust, and hose-directed water — common in water treatment and wastewater plants. Wall-mounted format keeps it off the floor in wet pits or chemical storage areas. Maximum ambient temperature is 40 °C, so it needs ventilation or derating if installed in a hot pump house or near process heat. ## Control and I/O complement Two analog inputs and two analog outputs handle pressure or flow transducer feedback and speed reference. Six digital inputs and three digital outputs manage start/stop, fault reset, and status feedback. Communication is over CAN bus — this is the native drive-to-drive link for the ACQ580 family; no built-in Ethernet port (0 industrial Ethernet interfaces). A CR2032 lithium coin cell (220 mAh, 3 V) backs the real-time clock and parameter storage. ## Standby loss and frequency range Standby loss of 14 W is low enough that the drive can be left powered when the pump is off — no forced cooling needed at idle.","metaTitle":"ABB 3AXD50001109479 ACQ580-01 Drive, 7.5 kW, IP66, Type 4X","metaDescription":"ABB ACQ580-01 wall-mounted drive, 7.5 kW / 10 Hp, 31.2 A, 200-240 V, IP66/NEMA 4X. Active production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 240V"],"specifications":{"Includes":"Control unit","Power Factor":"0.98","Standby Loss":"14 W","Analog Inputs":"2","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Wall-mounted","Analog Outputs":"2","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Temperature Rating":"Maximum 40 °C","Enclosure Type NEMA":"Type4X","Input Voltage (Uin)":"200 ... 240 V","Degree of Protection":"IP66","Apparent Power Output":"11.8 kV·A","Communication Protocol":"CAN","Multiple Battery Information":"Lithium Coin; CR2032; 220 mAh; 3 V; 1 pc; 3 g","Number of Digital In/Outputs":"6 / 3","Number of Hardware Interfaces":"Industrial Ethernet 0","Output Power, Normal Use (Pn)":"7.5 kW","Output Current, Normal Use (In)":"31.2 A","Output Power, Heavy-Duty Use (PhD)":"5.5 kW","Output Current, Heavy-Duty Use (IhD)":"24.2 A","Output Power, Light-Overload Use (PlD)":"7.5 kW","Output Current, Light-Overload Use (IlD)":"30.8 A","Technical UL/Output Power, Light-Overload Use (UL)":"10 Hp","Technical UL/Output Current, Light-Overload Use (UL)":"31 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3axd50001109479","alternativesUrl":"https://aoctrl.com/api/mcp/products/3AXD50001109479/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3AXD50001109479 and how do I get a price?","answer":"This drive is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ for current availability and pricing."},{"question":"What are the normal-use and heavy-duty current ratings for this drive?","answer":"Normal-use output is 31.2 A (7.5 kW); heavy-duty output is 24.2 A (5.5 kW). Light-overload use is 30.8 A (7.5 kW), matching the UL 10 Hp rating."},{"question":"What enclosure rating does this drive carry?","answer":"IP66 and NEMA Type 4X — suitable for washdown, hose-directed water, and dust. Wall-mounted for installation in wet or corrosive environments."},{"question":"Does this drive include the control unit?","answer":"Yes, the control unit is included with the drive — no separate purchase needed."},{"question":"What communication protocol does the 3AXD50001109479 use?","answer":"CAN bus is the native protocol. There are zero industrial Ethernet interfaces on this variant."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AXD50001109479","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AXD50001109479 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}