{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AXD50001109561","brand":"ABB","brandSlug":"abb","productSlug":"3AXD50001109561","canonicalUrl":"https://aoctrl.com/abb/3AXD50001109561","factsUrl":"https://aoctrl.com/api/mcp/products/3AXD50001109561","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACQ580-01 wall-mounted LV AC drive, 5.5 kW / 12.6 A normal use, 400 V, IP66, NEMA 4X, includes control unit.","salesMarkdown":"## Drive specs and fit This ABB ACQ580-01 (order code 3AXD50001109561) is a wall-mounted LV AC drive rated for 5.5 kW normal use at 12.6 A on a 400 V 3-phase supply. It's built for water and wastewater applications — the IP66 and NEMA Type 4X enclosure means it can sit outdoors or in washdown zones without an extra cabinet. The drive ships with the control unit included, so you don't need to order a separate controller card. Power factor sits at 0.98, and standby loss is a low 14 W — useful if the pump runs intermittently and you're tracking idle energy. The drive accepts line frequencies from 47.5 to 63 Hz, so it handles 50 Hz or 60 Hz supply without a firmware change. You get 2 analog inputs and 2 analog outputs for pressure or flow transducers, plus 6 digital inputs and 3 digital outputs for start/stop and status feedback. Communication is over CAN bus — there's no built-in Ethernet port, so if you need Ethernet/IP or Modbus TCP, you'll add an option module. The onboard CR2032 lithium coin cell keeps the real-time clock alive during power loss. ## Duty ratings and UL Three duty ratings cover the load profiles you'll see in the field. Normal use (Pn) is 5.5 kW at 12.6 A — that's the standard pump curve. Heavy-duty use (PhD) is 4 kW at 9.4 A for constant-torque loads like screw pumps or aerators. Light-overload use (PlD) is also 5.5 kW but at 12 A, with a UL listing of 8 Hp at 12 A on 460 V. Pick the duty that matches your motor's service factor.","metaTitle":"ABB 3AXD50001109561 ACQ580-01 Drive, 5.5 kW, IP66, NEMA 4X","metaDescription":"ABB ACQ580-01 wall-mounted LV AC drive for water/wastewater. 5.5 kW normal use, 12.6 A, 400 V, IP66, NEMA 4X. Active production. RFQ today.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Includes":"Control unit","Power Factor":"0.98","Standby Loss":"14 W","Analog Inputs":"2","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Wall-mounted","Analog Outputs":"2","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Temperature Rating":"Maximum 40 °C","Enclosure Type NEMA":"Type4X","Input Voltage (Uin)":"380 ... 415 V","Degree of Protection":"IP66","Apparent Power Output":"8.7 kV·A","Communication Protocol":"CAN","Multiple Battery Information":"Lithium Coin; CR2032; 220 mAh; 3 V; 1 pc; 3 g","Number of Digital In/Outputs":"6 / 3","Number of Hardware Interfaces":"Industrial Ethernet 0","Output Power, Normal Use (Pn)":"5.5 kW","Output Current, Normal Use (In)":"12.6 A","Output Power, Heavy-Duty Use (PhD)":"4 kW","Output Current, Heavy-Duty Use (IhD)":"9.4 A","Output Power, Light-Overload Use (PlD)":"5.5 kW","Output Current, Light-Overload Use (IlD)":"12 A","Technical UL/Output Power, Light-Overload Use (UL)":"8 Hp","Technical UL/Output Current, Light-Overload Use (UL)":"12 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3axd50001109561","alternativesUrl":"https://aoctrl.com/api/mcp/products/3AXD50001109561/alternatives.json"},"ai":{"faq":[{"question":"What is the closest alternative to this drive in the same family?","answer":"Within the ACQ580 family, the closest sibling would be a different power rating or enclosure variant. This specific order code is the 5.5 kW, IP66, NEMA 4X version with CAN bus. If you need a different power level or I/O count, check the ACQ580-01 series for matching voltage and enclosure."},{"question":"What does 'Includes Control unit' mean on this line?","answer":"It means the drive ships with the control unit already fitted — no separate purchase needed for the controller board. The control unit handles the drive logic, I/O, and communication interface."},{"question":"What is the power factor of this drive?","answer":"The power factor is 0.98, which is near unity. That means the drive draws mostly real power with low reactive component — good for utility billing and reduces the need for power factor correction."},{"question":"What compliance documentation is available for this drive?","answer":"The drive carries UL listing (8 Hp at 460 V light-overload) and is rated IP66/NEMA 4X. It's designed for IEC and UL markets. For specific RoHS, REACH, or other compliance certificates, request them with your RFQ."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AXD50001109561","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AXD50001109561 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}