{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AXD50001109646","brand":"ABB","brandSlug":"abb","productSlug":"3AXD50001109646","canonicalUrl":"https://aoctrl.com/abb/3AXD50001109646","factsUrl":"https://aoctrl.com/api/mcp/products/3AXD50001109646","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACH580-01 series, LV AC wall-mounted HVAC drive, 3AXD50001109646, 1.5 kW / 2 Hp, 7.6 A, 200-240 V, IP66/NEMA 4X, BACnet, IE2.","salesMarkdown":"The ABB 3AXD50001109646 is an ACH580-01 wall-mounted HVAC drive rated 1.5 kW normal-use (Pn) at 7.6 A on a 200-240 V three-phase supply. Heavy-duty output is 1.1 kW at 6.6 A; light-overload UL listing is 2 Hp at 7.5 A. The drive includes the control unit, two analog inputs and two analog outputs, plus 6 digital inputs and 3 digital outputs. BACnet is the onboard communication protocol — no option card needed for BAS integration. Enclosure is IP66 / NEMA 4X, so it can mount directly on the wall in washdown or outdoor locations without a separate cabinet. The 0.98 power factor is typical for a modern active-front-end drive — no need for external power-factor correction on the line side. Standby loss of 13 W matters for energy codes that penalize idle draw; this drive meets that threshold for most HVAC schedules. Maximum ambient is 40 °C; if the drive is in a hot mechanical room or direct sun, derate output current or add ventilation. ## Integration notes Wall-mounted means the drive has integral mounting tabs and a gland plate for cable entry — no backplate or sub-panel needed. The IP66 / NEMA 4X rating allows hose-down cleaning, so it suits food-processing or car-wash HVAC loops. The BACnet MS/TP port is standard; no gateway required to talk to a building controller. The lithium coin cell (CR2032, 220 mAh) keeps the real-time clock and parameter backup; replace it during commissioning if the drive has been in storage over a year.","metaTitle":"3AXD50001109646 ACH580-01 HVAC Drive, 1.5 kW, 7.6 A, IP66","metaDescription":"Active ABB ACH580-01 wall-mounted HVAC drive, 1.5 kW / 2 Hp, 7.6 A, 200-240 V, IP66/NEMA 4X, BACnet, IE2. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 240V"],"specifications":{"Includes":"Control unit","Power Factor":"0.98","Standby Loss":"13 W","Analog Inputs":"2","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Wall-mounted","Analog Outputs":"2","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Temperature Rating":"Maximum 40 °C","Enclosure Type NEMA":"Type4X","Input Voltage (Uin)":"200 ... 240 V","Degree of Protection":"IP66","Apparent Power Output":"3.0 kV·A","Communication Protocol":"BACNET","Multiple Battery Information":"Lithium Coin; CR2032; 220 mAh; 3 V; 1 pc; 3 g","Number of Digital In/Outputs":"6 / 3","Number of Hardware Interfaces":"Industrial Ethernet 0","Output Power, Normal Use (Pn)":"1.5 kW","Output Current, Normal Use (In)":"7.6 A","Output Power, Heavy-Duty Use (PhD)":"1.1 kW","Output Current, Heavy-Duty Use (IhD)":"6.6 A","Output Power, Light-Overload Use (PlD)":"1.5 kW","Output Current, Light-Overload Use (IlD)":"7.5 A","Technical UL/Output Power, Light-Overload Use (UL)":"2 Hp","Technical UL/Output Current, Light-Overload Use (UL)":"7.5 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3axd50001109646","alternativesUrl":"https://aoctrl.com/api/mcp/products/3AXD50001109646/alternatives.json"},"ai":{"faq":[{"question":"What are the key output ratings for this drive?","answer":"Normal-use output is 1.5 kW at 7.6 A; heavy-duty output is 1.1 kW at 6.6 A; light-overload UL rating is 2 Hp at 7.5 A. Input is 200-240 V three-phase."},{"question":"What enclosure protection does this drive have?","answer":"IP66 / NEMA 4X, suitable for outdoor or washdown installation without a separate cabinet."},{"question":"What communication protocol is built in?","answer":"BACnet MS/TP is the onboard protocol. No option card is required for building automation system integration."},{"question":"Does the drive include the control unit?","answer":"Yes, the control unit is included in the order code."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AXD50001109646","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AXD50001109646 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}