{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AXD50001109660","brand":"ABB","brandSlug":"abb","productSlug":"3AXD50001109660","canonicalUrl":"https://aoctrl.com/abb/3AXD50001109660","factsUrl":"https://aoctrl.com/api/mcp/products/3AXD50001109660","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACH580-01 wall-mounted HVAC drive, 3AXD50001109660, 4 kW (5 Hp) normal duty, 200-240 V 3-phase, IP66/NEMA 4X, BACnet, IE2.","salesMarkdown":"## What this ACH580-01 drive brings to an HVAC line The ABB 3AXD50001109660 is a wall-mounted ACH580-01 variable-frequency drive built for HVAC duty — IEC-rated 4 kW / 16.9 A normal use at 230 V, with a UL light-overload rating of 5 Hp / 17 A at 240 V. It ships as a complete control unit (Includes: Control unit), so no separate panel-mount kit is needed for the BACnet-connected jobs it's specced into. The IP66 / NEMA 4X enclosure means this drive can sit directly on the wall next to a rooftop AHU or a chiller — no secondary cabinet required for weather or washdown. Ambient limit is 40 °C; if the equipment room runs hotter, you'll need to derate the output current or add ventilation. ## Load ratings — normal, heavy, and light-overload curves Three duty curves are listed: normal-use (Pn) 4 kW / 16.9 A, heavy-duty (PhD) 3 kW / 10.6 A, and light-overload (PlD) 4 kW / 16.7 A. The heavy-duty figure governs continuous fan or pump loads with a constant-torque profile; the light-overload number is the one you'd size to for a variable-torque centrifugal load. The UL column confirms 5 Hp / 17 A light-overload, which is the rating most North American specs will reference. Apparent power output is 7.2 kV·A, and the power factor sits at 0.98 — that's the drive-side input PF, not the motor; it tells you the rectifier stage draws near-sinusoidal current, which keeps the upstream transformer and cabling sized closer to real power than apparent. ## I/O and fieldbus — what's on board Two analog inputs and two analog outputs are standard, plus 6 digital inputs and 3 digital outputs — enough for a basic pressure or temperature PID loop with a remote setpoint and a run-status relay back to the BAS. The communication protocol is BACnet (MS/TP or IP — the listing doesn't specify the physical layer, but the ACH580 family typically offers both on the same port). No Industrial Ethernet interface is listed; if you need PROFINET or EtherNet/IP, you'd add an optional fieldbus adapter module. A CR2032 lithium coin cell (220 mAh, 3 V) backs the real-time clock and parameter storage — standard across the ACH580 line. It's field-replaceable, so the drive doesn't lose its configuration when powered down for a panel swap. This is the current-production ACH580-01 variant for the 4 kW / 230 V segment.","metaTitle":"ABB 3AXD50001109660 ACH580-01 Drive, 4 kW / 5 Hp, IP66","metaDescription":"ABB 3AXD50001109660 ACH580-01 wall-mounted drive. 4 kW (5 Hp) at 230 V, IP66/NEMA 4X, BACnet, IE2. Active production. Quoted to order. Request RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 240V"],"specifications":{"Includes":"Control unit","Power Factor":"0.98","Standby Loss":"13 W","Analog Inputs":"2","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Wall-mounted","Analog Outputs":"2","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Temperature Rating":"Maximum 40 °C","Enclosure Type NEMA":"Type4X","Input Voltage (Uin)":"200 ... 240 V","Degree of Protection":"IP66","Apparent Power Output":"7.2 kV·A","Communication Protocol":"BACNET","Multiple Battery Information":"Lithium Coin; CR2032; 220 mAh; 3 V; 1 pc; 3 g","Number of Digital In/Outputs":"6 / 3","Number of Hardware Interfaces":"Industrial Ethernet 0","Output Power, Normal Use (Pn)":"4 kW","Output Current, Normal Use (In)":"16.9 A","Output Power, Heavy-Duty Use (PhD)":"3 kW","Output Current, Heavy-Duty Use (IhD)":"10.6 A","Output Power, Light-Overload Use (PlD)":"4 kW","Output Current, Light-Overload Use (IlD)":"16.7 A","Technical UL/Output Power, Light-Overload Use (UL)":"5 Hp","Technical UL/Output Current, Light-Overload Use (UL)":"17 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3axd50001109660","alternativesUrl":"https://aoctrl.com/api/mcp/products/3AXD50001109660/alternatives.json"},"ai":{"faq":[{"question":"What is the closest alternative to 3AXD50001109660?","answer":"The ACH580-01 family includes other power ratings at the same 200-240 V input voltage. The closest sibling is the next-lower or next-higher current frame (e.g., 012A-2 or 024A-2), but the 018A-2 rating in this order code is the 4 kW / 5 Hp sweet spot for typical HVAC fan and pump loads. No pin-compatible drop-in exists with a different power rating — you'd need to re-terminate the motor cables if the frame size changes."},{"question":"Where can I buy 3AXD50001109660 and get a price?","answer":"This drive is sourced to order against an RFQ through independent distribution. Submit a request for quote (RFQ) with your quantity and delivery window; availability and current pricing are confirmed at quote time."},{"question":"What compliance documentation does ABB provide for 3AXD50001109660?","answer":"The ACH580-01 series carries CE, UKCA, and UL/cUL markings. The UL listing is confirmed by the separate UL rating columns in the spec (5 Hp / 17 A at 240 V). RoHS and REACH declarations are available from ABB's documentation portal for the ACH580 family."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AXD50001109660","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AXD50001109660 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}