{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AXD50001158835","brand":"ABB","brandSlug":"abb","productSlug":"3AXD50001158835","canonicalUrl":"https://aoctrl.com/abb/3AXD50001158835","factsUrl":"https://aoctrl.com/api/mcp/products/3AXD50001158835","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACS580-07, LV AC general purpose cabinet-built drive, IEC: Pn 30 kW, 62 A, 400 V, UL: Pld 40 Hp, 52 A, 480 V.","salesMarkdown":"The ABB 3AXD50001158835 is an ACS580-07 LV AC general purpose cabinet-built drive, rated for 30 kW continuous output at 62 A on a 400 V three-phase supply. It ships as a complete control unit in a frame R4 cabinet, IP21 with NEMA Type 1 enclosure — ready for floor-mount installation. ## Duty ratings that matter The 62 A normal-use rating (In) covers continuous motor operation at 30 kW. For heavy-duty cycles — conveyors, crushers, or high-start-torque loads — the drive delivers 45 A / 22 kW (IhD / PhD). A light-overload tier at 58 A / 30 kW (IlD / PlD) sits between the two, giving flexibility for applications that don't need the full heavy-duty headroom but exceed normal continuous current. Under UL listing, the heavy-duty output is 40 A / 30 Hp, light-overload 52 A / 40 Hp. Built-in I/O includes 2 analog inputs, 2 analog outputs, 6 digital inputs, and 3 digital outputs — enough for basic speed reference, feedback, and run/stop control without an expansion module. Communication is CAN-based; there are no onboard industrial Ethernet ports. If your line uses PROFINET, EtherNet/IP, or Modbus TCP, plan for an optional fieldbus adapter.","metaTitle":"ABB 3AXD50001158835 ACS580-07 Drive, 30 kW, 62 A, 400 V","metaDescription":"ABB ACS580-07 cabinet-built drive, 30 kW / 62 A at 400 V, IP21, Type 1. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Includes":"Control unit","Frame Size":"R4","Sound dB (A)":"70 dB(A)","Analog Inputs":"2","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Cabinet-built","WEEE Category":"4. Large Equipment (Any External Dimension More Than 50 cm)","Analog Outputs":"2","lifecycle_stage":"current","Number of Phases":"3-phase","Temperature Rating":"Maximum 40 °C","Enclosure Type NEMA":"Type1","Input Voltage (Uin)":"380 ... 480 V","Degree of Protection":"IP21","Apparent Power Output":"43 kV·A","Communication Protocol":"CAN","Power Consumption (@Pcons)":"803 W","Multiple Battery Information":"Lithium Coin, CR2032, 220 mAh, 3 V, 1 pc, 3 g","Number of Digital In/Outputs":"6 / 3","Number of Hardware Interfaces":"Industrial Ethernet 0","Output Power, Normal Use (Pn)":"30 kW","Output Current, Normal Use (In)":"62 A","Output Power, Heavy-Duty Use (PhD)":"22 kW","Output Current, Heavy-Duty Use (IhD)":"45 A","Output Power, Light-Overload Use (PlD)":"30 kW","Output Current, Light-Overload Use (IlD)":"58 A","Technical UL/Output Power, Heavy-Duty Use (UL)":"30 Hp","Technical UL/Output Current, Heavy-Duty Use (UL)":"40 A","Technical UL/Output Power, Light-Overload Use (UL)":"40 Hp","Technical UL/Output Current, Light-Overload Use (UL)":"52 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3axd50001158835","alternativesUrl":"https://aoctrl.com/api/mcp/products/3AXD50001158835/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings of this drive?","answer":"Normal-use output is 30 kW / 62 A at 400 V. Heavy-duty output is 22 kW / 45 A. UL heavy-duty is 30 Hp / 40 A at 480 V. The drive accepts 380–480 V three-phase input at 47.5–63 Hz."},{"question":"What enclosure protection does it have?","answer":"IP21 with NEMA Type 1 enclosure, cabinet-built for floor mounting."},{"question":"What communication protocol does it support?","answer":"CAN is the onboard protocol. No industrial Ethernet ports are included — an optional fieldbus adapter is needed for PROFINET, EtherNet/IP, or Modbus TCP."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AXD50001158835","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AXD50001158835 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}