{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3G3RX2A4110","brand":"Omron","brandSlug":"omron","productSlug":"3G3RX2A4110","canonicalUrl":"https://aoctrl.com/omron/3G3RX2A4110","factsUrl":"https://aoctrl.com/api/mcp/products/3G3RX2A4110","rawCanonicalId":null},"summary":{"shortDescription":"Omron RX2 series AC drive, 3G3RX2A4110, 11 kW / 25 A rated, 380-500 VAC 3-phase input, 0-590 Hz output, IP20, wall-mount, RS-485 and USB interfaces.","salesMarkdown":"## 11 kW VFD for 400 V class motors The Omron 3G3RX2A4110 is an RX2-series AC drive rated for 11 kW output power with 25 A continuous current, designed for 3-phase 380-500 VAC input supplies — the standard 400 V industrial bus. This puts it in the sweet spot for powering 15 HP (11 kW) induction motors on pumps, fans, conveyors, and compressors in a panel environment. ## Output frequency and carrier tuning Output frequency spans 0 to 590 Hz, so the drive handles both standard 50/60 Hz motors and higher-speed spindles up to ~35,000 RPM (2-pole). The carrier (switching) frequency is adjustable from 500 Hz to 16 kHz — running at 16 kHz quiets audible motor whine but derates continuous output current; at 4 kHz the drive delivers full rated current with no thermal penalty. The RS-485 port supports Modbus RTU for PLC or SCADA integration, while the USB port (type mini-B) gives direct PC connection for drive setup and monitoring via Omron's CX-Drive software. No separate comms adapter needed for commissioning. Built-in analog inputs (0-10 V and 0-20 mA) accept speed reference from a potentiometer, 4-20 mA transducer, or analog output card. The relay output (2 A at 250 VAC) can signal drive fault, run status, or speed threshold to the control system. ## Panel mounting and thermal limits The drive is wall-mount with dimensions 260 mm high x 210 mm wide x 170 mm deep — it bolts directly to the backplate of an IP54 or higher enclosure. IP20 protection means the electronics are touch-safe but not sealed against dust or condensation, so an enclosure is required for washdown or outdoor locations. Ambient temperature range is -10 to 50 °C. In a sealed panel at 40 °C ambient, the drive's internal fan moves enough air to run full-rated current; above 40 °C, derating applies per the datasheet curves. The plug-in terminal blocks simplify wiring and replacement without removing the main power wires.","metaTitle":"Omron 3G3RX2A4110 RX2 AC Drive, 11 kW, 25 A, 380-500 VAC","metaDescription":"Omron RX2 3G3RX2A4110 AC drive, 11 kW / 25 A rated output, 380-500 VAC 3-phase input, 0-590 Hz output, IP20, RS-485/USB. Quoted to order against BOM.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Depth":"170 mm","Width":"210 mm","title":"3G3RX2A4110","Height":"260 mm","Series":"RX2","Rated Power":"11 kW","description":"Frequency Inverter, RX2, RS485 / USB, 25A, 11kW, 380... 500V","Input Phases":"3","Mounting Type":"Wall Mount","Output Phases":"3","Rated Current":"25 A","Interface Type":"RS485;USB","lifecycle_stage":"current","Termination Type":"Plug-In","Protection Rating":"IP20","Relay Output Type":"2 A @ 250 VAC","Digital Input Type":"24 VDC","Analogue Input Type":"0 ... 10 V;0 ... 20 mA","Digital Output Type":"Relay","Analogue Output Type":"0 ... 10 V;0 ... 20 mA","Input Frequency Max.":"60 Hz","Input Frequency Min.":"50 Hz","Output Frequency Max.":"590 Hz","Output Frequency Min.":"0 Hz","Operating Voltage Max.":"500 V","Operating Voltage Min.":"380 V","Clock/Pulse Frequency Max.":"16 kHz","Clock/Pulse Frequency Min.":"500 Hz","Operating Temperature Max.":"50 °C","Operating Temperature Min.":"-10 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$1,498.22","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/7c3885f44ded5d3b1a1d361ead895669.pdf","sourceUrl":null},"ai":{"faq":[{"question":"What is the 3G3RX2A4110 used for?","answer":"It's a variable frequency drive for 3-phase induction motors rated up to 11 kW (15 HP) on 380-500 VAC supplies. Typical loads include pumps, fans, conveyors, compressors, and general industrial machinery requiring adjustable speed control."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/omron/3G3RX2A4110","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/omron/3G3RX2A4110 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}