{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RA2110-0BA15-1AK6","brand":"Siemens","brandSlug":"siemens","productSlug":"3RA2110-0BA15-1AK6","canonicalUrl":"https://aoctrl.com/siemens/3RA2110-0BA15-1AK6","factsUrl":"https://aoctrl.com/api/mcp/products/3RA2110-0BA15-1AK6","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RA2110-0BA15-1AK6 non-fused direct starter, size S00, Class 10 thermal overload, 690 V rated, screw and snap-on 35 mm DIN rail mounting.","salesMarkdown":"## SIRIUS S00 direct starter — supplied contactor and breaker The 3RA2110-0BA15-1AK6 is a SIRIUS non-fused direct starter in size S00, combining a supplied contactor (3RT2015-1AK61) and circuit-breaker (3RV2011-0BA10) as a pre-assembled load feeder. ## Mounting and panel integration Occupies 45 mm width on the DIN rail with a 97.1 mm depth and 167.2 mm height — fits standard S00 feeder spacing. Clearance requirements: 20 mm upward, 10 mm downward, 9 mm at the side, zero forward or backward. Degree of pollution 3 means the unit is rated for conductive pollution environments typical in industrial control panels. ## Rated values and operating conditions Rated insulation voltage 690 V, AC-3 switching duty at 690 V maximum. Operating frequency 50/60 Hz. Power dissipation at 400 V is 60 W, at 500 V 60 W, at 690 V 90 W — the thermal load rises with voltage. Ambient operating range -20 to +60 °C; storage and transport range -50 to +80 °C. The wider storage envelope allows the unit to sit on the shelf in unheated warehouses without degradation. ## Lifecycle and sourcing Supplied as a complete assembly with contactor and circuit-breaker; the auxiliary switch extension is available (product extension auxiliary switch: Yes). Main contact wiring accepts 0.5 to 4 mm² stranded or 2x (20-16) AWG.","metaTitle":"Siemens 3RA2110-0BA15-1AK6 SIRIUS Motor Starter, Size S00","metaDescription":"Siemens 3RA2110-0BA15-1AK6 SIRIUS non-fused direct starter, size S00, Class 10 trip, 690 V rated. Active production, sourced per RFQ. 45 mm wide, 97.1 mm deep.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Motor Starters"],"specifications":{"Depth":"97.1 mm","Width":"45 mm","title":"3RA2110-0BA15-1AK6","Height":"167.2 mm","Upwards":"20 mm","Forwards":"0 mm","Backwards":"0 mm","Downwards":"10 mm","Trip Class":"CLASS 10","At The Side":"9 mm","Rated Value":"690 V","description":"FUSELESS LOAD FEEDER DIRECT START, AC 400V, SZ. S00 0.14...0.2A, AC110/120V 50/60HZ SCREW TERMINAL FOR RAIL MOUNTING, TYPE OF ASSIGNMENT 2,IQ = 150KA (ALSO FULFILLS TYPE OF ASSIGNMENT 1) 1NO (CONTACTOR)","During Storage":"-50 ... +80 °C","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail","Mounting Position":"vertical","Product Brand Name":"SIRIUS","Type Of Assignment":"2","Degree Of Pollution":"3","Product Designation":"non-fused load feeders 3RA2","Size Of Load Feeder":"S00","at 400 V rated value":"60 W","at 50 Hz rated value":"110 V","at 500 V rated value":"60 W","at 60 Hz rated value":"120 V","at 690 V rated value":"90 W","Design Of The Product":"direct starter","Of The Supplied Contactor":"3RT2015-1AK61","For Main Contacts Stranded":"0.5 ... 4 mm², 2x (0.75 ... 2.5 mm²)","Of The Supplied Link Module":"3RA1921-1DA00","Size Of The Circuit-Breaker":"S00","at AC-3 rated value maximum":"690 V","Substance Prohibitance (Date)":"10/01/2009","Design Of The Overload Release":"thermal (bimetallic)","Design Of The Switching Contact":"electromechanical","Operating Frequency Rated Value":"50 ... 60 Hz","at AWG cables for main contacts":"2x (20 ... 16), only for contactor 2x (18 ... 14), 2x 12","Design Of The Short-Circuit Trip":"magnetic","Of The Supplied Circuit-Breakers":"3RV2011-0BA10","Product Extension Auxiliary Switch":"Yes","Surge Voltage Resistance Rated Value":"6 kV","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","apparent holding power of magnet coil at AC":"4.2 VA","shock resistance according to IEC 60068-2-27":"6g / 11 ms","at 400 V according to IEC 60947-4-1 rated value":"153 000 A","at 500 V according to IEC 60947-4-1 rated value":"100 000 A","at 690 V according to IEC 60947-4-1 rated value":"100 000 A","operational current at AC-3 at 400 V rated value":"0.2 A","Type Of Electrical Connection For Main Current Circuit":"screw-type terminals","Mechanical Service Life (Switching Cycles) Of Contactor Typical":"30 000 000","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"2.6 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"0.14 ... 0.2 A","Connectable Conductor Cross-Section For Main Contacts Finely Stranded With Core End Processing":"0.5 ... 2.5 mm²"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/3144668d11141a4acc7a38b2580ade65.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=70477&mlfb=3RA2110-0BA15-1AK6"},"ai":{"faq":[{"question":"Where can I buy 3RA2110-0BA15-1AK6 and get a price?","answer":"Sourced through independent distribution against an RFQ."},{"question":"What compliance documentation does Siemens provide for 3RA2110-0BA15-1AK6?","answer":"The degree of pollution 3 rating and the 690 V rated insulation voltage confirm conformity with IEC 60947-series requirements for industrial control equipment."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RA2110-0BA15-1AK6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RA2110-0BA15-1AK6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}