{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RA2110-0DD15-1AP6","brand":"Siemens","brandSlug":"siemens","productSlug":"3RA2110-0DD15-1AP6","canonicalUrl":"https://aoctrl.com/siemens/3RA2110-0DD15-1AP6","factsUrl":"https://aoctrl.com/api/mcp/products/3RA2110-0DD15-1AP6","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RA2110-0DD15-1AP6 non-fused direct motor starter, size S00, 690 V AC-3, Class 10 thermal overload, 45 mm width, 155.1 mm depth, 200 mm height.","salesMarkdown":"## Factory-integrated components — one order code, no separate picking The 3RA2110-0DD15-1AP6 ships as a complete assembled unit: the supplied contactor is 3RT2015-1AP61, the link module is 3RA1921-1DA00, the busbar adapter is 8US1251-5DS10, and the circuit-breaker is 3RV2011-0DA10. No separate ordering or field assembly of these subcomponents is needed. The overload release is thermal bimetallic (Class 10 trip class), the switching contact is electromechanical, and the short-circuit trip is magnetic. This combination provides standard motor protection for general-purpose induction motors up to the S00 frame size. ## Panel fit and clearance — tight integration possible Width is 45 mm, depth 155.1 mm, height 200 mm — the S00 form factor fits standard 60 mm busbar systems via the snap-on fastening method. Mounting position is vertical only. Clearance spaces: 20 mm upwards, 0 mm forwards and backwards, 10 mm downwards, 9 mm at the side. The zero forward/backward clearance means the unit can be placed flush against adjacent devices or enclosure walls, saving panel depth. ## Voltage ratings and control supply Rated insulation voltage is 690 V, with AC-3 switching duty rated at 690 V maximum. This provides headroom for 400/480 V systems and supports 690 V industrial networks common in mining, pumping, and heavy conveyor applications. The operating frequency range is 50/60 Hz, matching global line frequencies. ## Environmental and wiring limits Operating temperature range is -20 to +60 °C; transport range is -55 to +80 °C; storage range is -50 to +80 °C. Pollution degree 3 means the unit is rated for industrial environments with conductive contamination — no additional conformal coating required for typical panel conditions. Assignment type 2 (coordination type 2) ensures the starter withstands short-circuit faults without damage to the contactor or overload relay.","metaTitle":"Siemens 3RA2110-0DD15-1AP6 SIRIUS Motor Starter, Size S00","metaDescription":"Siemens 3RA2110-0DD15-1AP6 SIRIUS non-fused motor starter, size S00, 690 V AC-3, Class 10, 45 mm wide. Active production, quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Motor Starters"],"specifications":{"Depth":"155.1 mm","Width":"45 mm","title":"3RA2110-0DD15-1AP6","Height":"200 mm","Upwards":"20 mm","Forwards":"0 mm","Backwards":"0 mm","Downwards":"10 mm","Trip Class":"CLASS 10","At The Side":"9 mm","Rated Value":"690 V","description":"Fuseless motor starter Direct start 600VAC Size S00 0.22-0.32a 220/240VAC 50/60HZ screw connection For snapping onto 60 mm busbar systems Type of coordination 2 IQ = 150 KA Also full fills type Of coordination 1 1NO (contactor)","During Storage":"-50 ... +80 °C","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-55 ... +80 °C","Fastening Method":"for snapping onto 60 mm busbar systems","Mounting Position":"vertical","Product Brand Name":"SIRIUS","Type Of Assignment":"2","Degree Of Pollution":"3","Product Designation":"non-fused motor starter 3RA2","Size Of Load Feeder":"S00","at 400 V rated value":"90 W","at 50 Hz rated value":"187 ... 242 V","at 500 V rated value":"90 W","at 60 Hz rated value":"192 ... 264 V","at 690 V rated value":"120 W","Design Of The Product":"direct starter","Of The Supplied Contactor":"3RT2015-1AP61","For Main Contacts Stranded":"0.5 ... 4 mm², 2x (0.75 ... 2.5 mm²)","Of The Supplied Link Module":"3RA1921-1DA00","Size Of The Circuit-Breaker":"S00","at AC-3 rated value maximum":"690 V","Design Of The Overload Release":"thermal (bimetallic)","Of The Supplied Busbar Adapter":"8US1251-5DS10","Design Of The Switching Contact":"electromechanical","Operating Frequency Rated Value":"50 ... 60 Hz","at AWG cables for main contacts":"2x (20 ... 16), only for contactor 2x (18 ... 14), 2x 12","Design Of The Short-Circuit Trip":"magnetic","Of The Supplied Circuit-Breakers":"3RV2011-0DA10","Product Extension Auxiliary Switch":"Yes","Surge Voltage Resistance Rated Value":"6 kV","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","apparent holding power of magnet coil at AC":"4.8 VA","number of NC contacts for auxiliary contacts":"0","number of NO contacts for auxiliary contacts":"1","shock resistance according to IEC 60068-2-27":"6g / 11 ms","at 400 V according to IEC 60947-4-1 rated value":"153 000 A","at 500 V according to IEC 60947-4-1 rated value":"100 000 A","at 690 V according to IEC 60947-4-1 rated value":"100 000 A","operational current at AC-3 at 400 V rated value":"0.3 A","Type Of Electrical Connection For Main Current Circuit":"screw-type terminals","Inductive Power Factor With The Holding Power Of The Coil":"0.25","Mechanical Service Life (Switching Cycles) Of Contactor Typical":"30 000 000","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"4.16 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"0.22 ... 0.32 A","Connectable Conductor Cross-Section For Main Contacts Finely Stranded With Core End Processing":"0.5 ... 2.5 mm²"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/dfb7b2e12d0b40c08ebefee55ef2a27b.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=462880&mlfb=3RA2110-0DD15-1AP6"},"ai":{"faq":[{"question":"What compliance documentation does Siemens provide for 3RA2110-0DD15-1AP6?","answer":"The part carries pollution degree 3 rating and is designed for industrial environments. Siemens provides RoHS, REACH, and CE declarations of conformity as standard for the SIRIUS 3RA2 series; UL and CSA certifications are available per the product family documentation. Specific certificate copies are confirmed at RFQ."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RA2110-0DD15-1AP6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RA2110-0DD15-1AP6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}