{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RA2110-0FA15-1AP6","brand":"Siemens","brandSlug":"siemens","productSlug":"3RA2110-0FA15-1AP6","canonicalUrl":"https://aoctrl.com/siemens/3RA2110-0FA15-1AP6","factsUrl":"https://aoctrl.com/api/mcp/products/3RA2110-0FA15-1AP6","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RA2110-0FA15-1AP6 non-fused motor starter, Size S00, direct starter, 120 W rated power at 400 V, Class 10 trip class, 45 mm width, snap-on DIN rail mount.","salesMarkdown":"The 3RA2110-0FA15-1AP6 is a Siemens SIRIUS non-fused motor starter, assembled as a direct starter in Size S00. It ships as a factory-matched set: the 3RT2015-1AP61 contactor, the 3RV2011-0FA10 circuit-breaker, and the 3RA1921-1DA00 link module, all pre-configured for a Type 2 coordination. Rated motor power is 120 W at 400 V, 180 W at 500 V, and 250 W at 690 V. The overload release is thermal bimetallic; the short-circuit release is magnetic. This combination provides both overload protection (heating curve) and instantaneous magnetic trip for fault currents. The contactor is electromechanical, rated for AC-3 switching duty up to 690 V. ## Mounting and panel integration — 45 mm width, DIN rail snap-on Width is 45 mm, depth 97.1 mm, height 167.2 mm. The unit snaps onto a DIN rail or can be screw-mounted with an additional push-in lug. Mounting position is vertical. Required clearances: 20 mm upward, 10 mm downward, 9 mm at the side, 0 mm forward and backward. These gaps allow airflow for the thermal overload and arc-fault venting from the circuit-breaker. In a crowded panel, the 45 mm width per feeder keeps the density reasonable for Size S00. AWG equivalents are 2× (20 to 16), 2× (18 to 14), or 2× 12. The auxiliary switch can be field-added. ## Coil voltage and environmental ratings This covers nominal 208–240 V supplies with tolerance. Rated insulation voltage is 690 V; surge voltage resistance is 6 kV. Ambient operating range is -20 to +60 °C; storage range is -50 to +80 °C; transport range is -55 to +80 °C. Pollution degree 3 means the unit is rated for industrial environments with conductive pollution. ## Sourcing and lifecycle — current production, quoted to order The 3RA2 series is the standard SIRIUS non-fused motor starter line; the Size S00 frame covers the lower power range up to approximately 250 W at 690 V.","metaTitle":"Siemens 3RA2110-0FA15-1AP6 SIRIUS Motor Starter, Size S00","metaDescription":"Siemens 3RA2110-0FA15-1AP6 SIRIUS non-fused motor starter, Size S00, direct starter, 120 W at 400 V, Class 10, 45 mm wide. Current production, quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Motor Starters"],"specifications":{"Depth":"97.1 mm","Width":"45 mm","title":"3RA2110-0FA15-1AP6","Height":"167.2 mm","Upwards":"20 mm","Forwards":"0 mm","Backwards":"0 mm","Downwards":"10 mm","Trip Class":"CLASS 10","At The Side":"9 mm","Rated Value":"690 V","description":"Fuseless motor starter Direct start 600VAC Size S00 0.35-0.5A 220/240VAC 50/60HZ screw connection For screw mounting Or 35 mm rail-mounting Type of coordination 2 IQ = 150 KA Also full fills type Of coordination 1 1NO (contactor)","During Storage":"-50 ... +80 °C","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-55 ... +80 °C","Fastening Method":"Snap-mounted to DIN rail or screw-mounted with additional push-in lug","Mounting Position":"vertical","Product Brand Name":"SIRIUS","Type Of Assignment":"2","Degree Of Pollution":"3","Product Designation":"non-fused motor starter 3RA2","Size Of Load Feeder":"S00","at 400 V rated value":"120 W","at 50 Hz rated value":"187 ... 242 V","at 500 V rated value":"180 W","at 60 Hz rated value":"192 ... 264 V","at 690 V rated value":"250 W","Design Of The Product":"direct starter","Of The Supplied Contactor":"3RT2015-1AP61","For Main Contacts Stranded":"0.5 ... 4 mm², 2x (0.75 ... 2.5 mm²)","Of The Supplied Link Module":"3RA1921-1DA00","Size Of The Circuit-Breaker":"S00","at AC-3 rated value maximum":"690 V","Design Of The Overload Release":"thermal (bimetallic)","Design Of The Switching Contact":"electromechanical","Operating Frequency Rated Value":"50 ... 60 Hz","at AWG cables for main contacts":"2x (20 ... 16), only for contactor 2x (18 ... 14), 2x 12","Design Of The Short-Circuit Trip":"magnetic","Of The Supplied Circuit-Breakers":"3RV2011-0FA10","Product Extension Auxiliary Switch":"Yes","Surge Voltage Resistance Rated Value":"6 kV","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","apparent holding power of magnet coil at AC":"4.8 VA","number of NC contacts for auxiliary contacts":"0","number of NO contacts for auxiliary contacts":"1","shock resistance according to IEC 60068-2-27":"6g / 11 ms","at 400 V according to IEC 60947-4-1 rated value":"153 000 A","at 500 V according to IEC 60947-4-1 rated value":"100 000 A","at 690 V according to IEC 60947-4-1 rated value":"100 000 A","operational current at AC-3 at 400 V rated value":"0.4 A","Type Of Electrical Connection For Main Current Circuit":"screw-type terminals","Inductive Power Factor With The Holding Power Of The Coil":"0.25","Mechanical Service Life (Switching Cycles) Of Contactor Typical":"30 000 000","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"6.5 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"0.35 ... 0.5 A","Connectable Conductor Cross-Section For Main Contacts Finely Stranded With Core End Processing":"0.5 ... 2.5 mm²"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c02e3f842376f505f133633c4867c0a7.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=419759&mlfb=3RA2110-0FA15-1AP6"},"ai":{"faq":[{"question":"What is the rated motor power of 3RA2110-0FA15-1AP6 at 400 V?","answer":"Rated motor power is 120 W at 400 V, 180 W at 500 V, and 250 W at 690 V. These values apply for AC-3 duty."},{"question":"What components are supplied with the 3RA2110-0FA15-1AP6 motor starter?","answer":"The assembly includes the 3RT2015-1AP61 contactor, the 3RV2011-0FA10 circuit-breaker, and the 3RA1921-1DA00 link module, factory-configured for Type 2 coordination."},{"question":"What is the width and mounting method of the 3RA2110-0FA15-1AP6?","answer":"Width is 45 mm, depth 97.1 mm, height 167.2 mm. It snaps onto a DIN rail or can be screw-mounted with an additional push-in lug. Mounting position is vertical."},{"question":"What compliance documentation does Siemens provide for 3RA2110-0FA15-1AP6?","answer":"Full compliance documentation (RoHS, REACH, UL, IEC) is available from Siemens per their standard declarations for the SIRIUS 3RA2 series."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RA2110-0FA15-1AP6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RA2110-0FA15-1AP6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}