{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RA2110-0GA15-1AK6","brand":"Siemens","brandSlug":"siemens","productSlug":"3RA2110-0GA15-1AK6","canonicalUrl":"https://aoctrl.com/siemens/3RA2110-0GA15-1AK6","factsUrl":"https://aoctrl.com/api/mcp/products/3RA2110-0GA15-1AK6","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RA2110-0GA15-1AK6 non-fused load feeder, size S00, direct starter, 690 V AC-3, 50-60 Hz, includes contactor and circuit-breaker, screw and snap-on 35 mm DIN rail mounting.","salesMarkdown":"## What ships in the carton — a complete motor branch kit The 3RA2110-0GA15-1AK6 is a factory-assembled non-fused load feeder in size S00, combining a 3RT2015-1AK61 contactor and a 3RV2011-0GA10 circuit-breaker on a common mounting base. It ships as a single order code — no separate sourcing of the contactor, breaker, or link module. The supplied link module 3RA1921-1DA00 pre-wires the contactor coil and breaker auxiliary contacts internally, so the kit lands with the internal control wiring already in place. The only field terminations are the main power wires and the control signal to the coil. Rated for AC-3 duty up to 690 V, this direct starter handles motor loads up to 180 W at 400 V, 180 W at 500 V, and 250 W at 690 V — covering small pump, fan, and conveyor motors in a single enclosure footprint. ## Panel fit and clearance — what the dimensions mean for layout The load feeder measures 45 mm wide, 97.1 mm deep, and 167.2 mm tall — a size S00 footprint that fits standard 35 mm DIN rail with screw and snap-on fastening. Mounting position must be vertical per the spec. Clearance requirements: 20 mm upwards, 10 mm downwards, 9 mm at the sides, and zero forwards or backwards. These gaps allow heat from the thermal bimetallic overload release to dissipate and give the magnetic short-circuit trip room to vent arc gases during a fault event. Pollution degree 3 rating means the unit is designed for industrial environments with conductive dust or occasional condensation — no additional conformal coating needed in a standard IP54 enclosure. ## Motor protection coordination — Trip Class 10 and thermal overload This protects standard squirrel-cage motors during locked-rotor conditions without nuisance tripping on normal starting current. The magnetic short-circuit trip provides instantaneous fault clearing — coordinated with the 3RV2011-0GA10 circuit-breaker's own magnetic release for selectivity downstream. The combination meets the requirements of IEC 60947-4-1 for coordinated motor starter protection. Operating temperature range is -20 to +60 °C during operation, with storage and transport tolerance from -50 to +80 °C. ## Wiring and termination — conductor sizes and auxiliary options AWG equivalents: 2× (20-16) or 2× (18-14) or 2× 12 for the contactor side. The product extension auxiliary switch is available — the base unit has the mechanical interface for adding auxiliary contact blocks without removing the load feeder from the DIN rail. This allows status feedback to a PLC or remote I/O without extra wiring looms. Rated insulation voltage is 690 V, matching the AC-3 maximum switching voltage. ## Sourcing and lifecycle — current production, quoted to order No direct functional second-source exists for this factory-assembled combination — the 6ES7517-3FP00-0AB0 is a Siemens PLC module, not a load feeder, and cannot drop into the same panel position without complete rewiring. The 3RA2 series is the only form-fit-function match for the S00 footprint. The unit ships as a complete kit — no separate ordering of the contactor, breaker, or link module.","metaTitle":"Siemens 3RA2110-0GA15-1AK6 SIRIUS Load Feeder, Size S00","metaDescription":"Siemens 3RA2110-0GA15-1AK6 SIRIUS non-fused load feeder, size S00, direct starter, 690 V AC-3, includes 3RT2015-1AK61 contactor and 3RV2011-0GA10","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Motor Starters"],"specifications":{"Depth":"97.1 mm","Width":"45 mm","title":"3RA2110-0GA15-1AK6","Height":"167.2 mm","Upwards":"20 mm","Forwards":"0 mm","Backwards":"0 mm","Downwards":"10 mm","Trip Class":"CLASS 10","At The Side":"9 mm","Rated Value":"690 V","description":"FUSELESS LOAD FEEDER DIRECT START, AC 400V, SZ. S00 0.45...0.63A,AC110/120V 50/60HZ SCREW TERMINAL FOR RAIL MOUNTING, TYPE OF ASSIGNMENT 2,IQ = 150KA (ALSO FULFILLS TYPE OF ASSIGNMENT 1) 1NO (CONTACTOR)","During Storage":"-50 ... +80 °C","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail","Mounting Position":"vertical","Product Brand Name":"SIRIUS","Type Of Assignment":"2","Degree Of Pollution":"3","Product Designation":"non-fused load feeders 3RA2","Size Of Load Feeder":"S00","at 400 V rated value":"180 W","at 50 Hz rated value":"110 V","at 500 V rated value":"180 W","at 60 Hz rated value":"120 V","at 690 V rated value":"250 W","Design Of The Product":"direct starter","Of The Supplied Contactor":"3RT2015-1AK61","For Main Contacts Stranded":"0.5 ... 4 mm², 2x (0.75 ... 2.5 mm²)","Of The Supplied Link Module":"3RA1921-1DA00","Size Of The Circuit-Breaker":"S00","at AC-3 rated value maximum":"690 V","Substance Prohibitance (Date)":"10/01/2009","Design Of The Overload Release":"thermal (bimetallic)","Design Of The Switching Contact":"electromechanical","Operating Frequency Rated Value":"50 ... 60 Hz","at AWG cables for main contacts":"2x (20 ... 16), only for contactor 2x (18 ... 14), 2x 12","Design Of The Short-Circuit Trip":"magnetic","Of The Supplied Circuit-Breakers":"3RV2011-0GA10","Product Extension Auxiliary Switch":"Yes","Surge Voltage Resistance Rated Value":"6 kV","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","apparent holding power of magnet coil at AC":"4.2 VA","shock resistance according to IEC 60068-2-27":"6g / 11 ms","at 400 V according to IEC 60947-4-1 rated value":"153 000 A","at 500 V according to IEC 60947-4-1 rated value":"100 000 A","at 690 V according to IEC 60947-4-1 rated value":"100 000 A","operational current at AC-3 at 400 V rated value":"0.6 A","Type Of Electrical Connection For Main Current Circuit":"screw-type terminals","Mechanical Service Life (Switching Cycles) Of Contactor Typical":"30 000 000","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"8.19 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"0.45 ... 0.63 A","Connectable Conductor Cross-Section For Main Contacts Finely Stranded With Core End Processing":"0.5 ... 2.5 mm²"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/5500fdc9f7fd39684e633befa0c181c1.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=514481&mlfb=3RA2110-0GA15-1AK6"},"ai":{"faq":[{"question":"What compliance documentation is available for the 3RA2110-0GA15-1AK6?","answer":"It is designed to IEC 60947-4-1 for coordinated motor starter protection, with pollution degree 3 for industrial environments."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RA2110-0GA15-1AK6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RA2110-0GA15-1AK6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}