{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RA2110-0GD15-1BB4","brand":"Siemens","brandSlug":"siemens","productSlug":"3RA2110-0GD15-1BB4","canonicalUrl":"https://aoctrl.com/siemens/3RA2110-0GD15-1BB4","factsUrl":"https://aoctrl.com/api/mcp/products/3RA2110-0GD15-1BB4","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS direct-on-line starter, 3RA2110-0GD15-1BB4, size S00, 180 W at 400 V, CLASS 10, for 60 mm busbar systems.","salesMarkdown":"## What this starter package includes — and what it saves you wiring The 3RA2110-0GD15-1BB4 is a Siemens SIRIUS direct-on-line starter, size S00, pre-configured for snapping onto 60 mm busbar systems — it ships as a coordinated assembly with the contactor (3RT2015-1BB41), link module (3RA1921-1DA00), busbar adapter (8US1251-5DS10), and circuit-breaker (3RV2011-0GA10) already matched. That means one order code gets you the motor branch circuit protection, switching, and overload protection in a single DIN-rail-compatible footprint — no separate breaker, contactor, and overload relay to select and interconnect. ## Motor ratings and trip class — what the numbers mean for a real load Rated motor power is 180 W at 400 V, 50-60 Hz, with a full-load current of 0.63 A at 480 V — this is a fractional-horsepower starter for small pumps, fans, conveyors, or valve actuators. ## Mounting and clearances — fitting this into a panel or busbar system The starter snaps onto 60 mm busbar systems (vertical mounting position only) and measures 155 mm deep × 45 mm wide × 200 mm tall — the S00 feeder size keeps the panel fill factor tight. Required clearances: 50 mm above, 20 mm forward, 0 mm behind, 10 mm below, and 20 mm to the side — the zero rear clearance means it can sit flush against a backplate, but the forward clearance matters for the busbar adapter and wiring access. ## Environmental limits and compliance paperwork Operating temperature range is -20 to +60 °C, with storage and transport limits of -50 to +80 °C — adequate for most indoor panel environments but check the ambient near ovens or freezers. The overload release includes temperature compensation across the -20 to +60 °C operating range, so the trip curve stays stable without manual adjustment when the panel warms up. Sourced through independent industrial distribution; availability and volume pricing confirmed at RFQ against the BOM quantity. No minimum order quantity is assumed — quoted per project need. The supplied contactor (3RT2015-1BB41), link module (3RA1921-1DA00), busbar adapter (8US1251-5DS10), and circuit-breaker (3RV2011-0GA10) are all standard SIRIUS catalog items, so replacement parts are available individually if a component fails in the field.","metaTitle":"Siemens 3RA2110-0GD15-1BB4 SIRIUS DOL Starter, S00","metaDescription":"Siemens SIRIUS 3RA2110-0GD15-1BB4 direct-on-line starter, size S00, 180W at 400V, CLASS 10 trip, for 60mm busbars. Active production, quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Starters"],"specifications":{"Depth":"155 mm","Width":"45 mm","title":"3RA2110-0GD15-1BB4","Height":"200 mm","Upwards":"50 mm","Forwards":"20 mm","Stranded":"0.5 ... 4 mm², 2x (0.75 ... 2.5 mm²)","Backwards":"0 mm","Downwards":"10 mm","Trip Class":"CLASS 10","At The Side":"20 mm","Rated Value":"24 ... 24 V","description":"Load feeder fuseless, Direct-on-line starting 400 V AC, Size S00 0.45...0.63 A 24 V DC screw terminal for 60 mm busbar systems (also fulfills type of coordination 1) Type of coordination 2, Iq = 150 kA 1 NO (contactor)","During Storage":"-50 ... +80 °C","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"for snapping onto 60 mm busbar systems","Mounting Position":"vertical","PROFIsafe protocol":"No","Product Brand Name":"SIRIUS","Type Of Assignment":"2","Product Designation":"Direct (on-line) starter","Size Of Load Feeder":"S00","PROFINET IO protocol":"No","at 400 V rated value":"180 W","at 480 V rated value":"0.63 A","Design Of The Product":"for 60 mm busbars","For Main Current Circuit":"screw-type terminals","Temperature Compensation":"-20 ... +60 °C","Of The Supplied Contactor":"3RT2015-1BB41","Of The Supplied Link Module":"3RA1921-1DA00","Size Of The Circuit-Breaker":"S00","at AC-3 rated value maximum":"690 V","Substance Prohibitance (Date)":"10/01/2009","Design Of The Overload Release":"thermal (bimetallic)","Of The Supplied Busbar Adapter":"8US1251-5DS10","Design Of The Switching Contact":"electromechanical","Operating Frequency Rated Value":"50 ... 60 Hz","at AWG cables for main contacts":"2x (20 ... 16), only for contactor 2x (18 ... 14), 2x 12","Design Of The Short-Circuit Trip":"magnetic","Of The Supplied Circuit-Breakers":"3RV2011-0GA10","degree of protection NEMA rating":"other","For Auxiliary And Control Circuit":"screw-type terminals","Product Extension Auxiliary Switch":"Yes","Relative Humidity During Operation":"10 ... 95 %","holding power of magnet coil at DC":"4 W","Surge Voltage Resistance Rated Value":"6 kV","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","protocol is supported AS-Interface protocol":"No","with high demand rate according to SN 31920":"73 %","shock resistance according to IEC 60068-2-27":"6g / 11 ms","Type Of Voltage Of The Control Supply Voltage":"DC","at 400 V according to IEC 60947-4-1 rated value":"150 000 A","operational current at AC-3 at 400 V rated value":"0.6 A","Mechanical Service Life (Switching Cycles) Of Contactor Typical":"30 000 000","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"0.45 ... 0.63 A","Connectable Conductor Cross-Section For Main Contacts Finely Stranded With Core End Processing":"0.5 ... 2.5 mm²"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/420027821e216951bd4e88bf881d6453.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=202202&mlfb=3RA2110-0GD15-1BB4"},"ai":{"faq":[{"question":"What components are included with this starter?","answer":"The 3RA2110-0GD15-1BB4 ships as a coordinated assembly including the contactor (3RT2015-1BB41), link module (3RA1921-1DA00), busbar adapter (8US1251-5DS10), and circuit-breaker (3RV2011-0GA10) — all pre-matched for the S00 frame."},{"question":"What is the motor power rating of this starter?","answer":"Rated motor power is 180 W at 400 V, 50-60 Hz, with a full-load current of 0.63 A at 480 V. The maximum switching voltage in AC-3 duty is 690 V."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RA2110-0GD15-1BB4","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RA2110-0GD15-1BB4 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}