{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RA2110-0HH15-1BB4","brand":"Siemens","brandSlug":"siemens","productSlug":"3RA2110-0HH15-1BB4","canonicalUrl":"https://aoctrl.com/siemens/3RA2110-0HH15-1BB4","factsUrl":"https://aoctrl.com/api/mcp/products/3RA2110-0HH15-1BB4","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RA2110-0HH15-1BB4 direct online motor starter, size S00, 0.8 A AC-3 at 400 V, 180 kW, 24 V DC coil, Class 10, spring-loaded terminals, snap-on for 60 mm busbar systems.","salesMarkdown":"## SIRIUS direct online starter — size S00, 0.8 A, 180 kW The 3RA2110-0HH15-1BB4: It ships as a pre-assembled unit including the 3RT2015-2BB41 contactor, the 3RA2911-2AA00 link module, and the 8US1251-5DT11 busbar adapter — everything needed to snap onto a 60 mm busbar system and wire the main circuit via spring-loaded terminals. The vertical mounting position and the clearance requirements (50 mm upwards, 20 mm forwards, 10 mm downwards, 20 mm at the side) should be checked against the enclosure layout before installation. ## What the 0.8 A AC-3 rating means for motor control The AC-3e rating at 400 V is also 0.8 A, confirming the same capability under the enhanced IEC/EN 60947-4-1 test cycle. The maximum AC-3 voltage is 690 V, giving headroom for 480 V or 600 V line supplies. The operating temperature range of -20 to +60 °C covers most industrial environments, and the storage/transport range of -50 to +80 °C means it can sit in a warehouse or truck without issue. ## Current production — sourcing and compliance For BOM planning, the dimensions are 155 mm depth, 45 mm width, and 260 mm height — the 45 mm width is a single S00 module slot on a 60 mm busbar system. The spring-loaded terminals accept solid or stranded copper wire without needing ferrules for the main circuit, which speeds up panel wiring.","metaTitle":"Siemens 3RA2110-0HH15-1BB4 SIRIUS Motor Starter, 0.8 A","metaDescription":"Siemens 3RA2110-0HH15-1BB4 SIRIUS direct online motor starter, size S00, 0.8 A AC-3 at 400 V, 180 kW, 24 V coil, Class 10, snap-on 60 mm busbar.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Starters"],"specifications":{"Depth":"155 mm","Width":"45 mm","title":"3RA2110-0HH15-1BB4","Height":"260 mm","Upwards":"50 mm","Forwards":"20 mm","Backwards":"0 mm","Downwards":"10 mm","Trip Class":"CLASS 10","At The Side":"20 mm","Rated Value":"24 ... 24 V","description":"Load feeder fuseless, Direct-on-line starting 400 V AC, Size S00 0.55...0.80 A 24 V DC Spring-type terminal for 60 mm busbar systems (also fulfills type of coordination 1) Type of coordination 2, Iq = 150 kA 1 NO (contactor)","During Storage":"-50 ... +80 °C","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"for snapping onto 60 mm busbar systems","Mounting Position":"vertical","PROFIsafe protocol":"No","Product Brand Name":"SIRIUS","Type Of Assignment":"2","Product Designation":"Direct (on-line) starter","Size Of Load Feeder":"S00","PROFINET IO protocol":"No","at 400 V rated value":"180 kW","at 480 V rated value":"0.8 A","at 600 V rated value":"0.8 A","Design Of The Product":"for 60 mm busbars","For Main Current Circuit":"spring-loaded terminals","Temperature Compensation":"-20 ... +60 °C","at 460/480 V rated value":"0.5 hp","at 575/600 V rated value":"0.5 hp","Of The Supplied Contactor":"3RT2015-2BB41","Of The Supplied Link Module":"3RA2911-2AA00","Size Of The Circuit-Breaker":"S00","at AC-3 rated value maximum":"690 V","at AC-3 at 400 V rated value":"0.8 A","at AC-3e rated value maximum":"690 V","Substance Prohibitance (Date)":"10/01/2009","at AC-3e at 400 V rated value":"0.8 A","Design Of The Overload Release":"thermal (bimetallic)","Of The Supplied Busbar Adapter":"8US1251-5DT11","Design Of The Switching Contact":"electromechanical","Operating Frequency Rated Value":"50 ... 60 Hz","Design Of The Short-Circuit Trip":"magnetic","Of The Supplied Circuit-Breakers":"3RV2011-0HA20","degree of protection NEMA rating":"other","For Auxiliary And Control Circuit":"spring-loaded terminals","Product Extension Auxiliary Switch":"Yes","Relative Humidity During Operation":"10 ... 95 %","Without Load Current Share Typical":"4 W","holding power of magnet coil at DC":"4 W","Surge Voltage Resistance Rated Value":"6 kV","at AC in hot operating state per pole":"2.6 W","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","protocol is supported AS-Interface protocol":"No","with high demand rate according to SN 31920":"73 %","reference code according to IEC 81346-2:2019":"Q","shock resistance according to IEC 60068-2-27":"6g / 11 ms","Type Of Voltage Of The Control Supply Voltage":"DC","at 400 V according to IEC 60947-4-1 rated value":"150 000 A","Mechanical Service Life (Operating Cycles) Of Contactor Typical":"30 000 000","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"10 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"0.55 ... 0.8 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ee67a4d94fad5be00a4a92f8ec6b75df.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=27112&mlfb=3RA2110-0HH15-1BB4"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RA2110-0HH15-1BB4","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RA2110-0HH15-1BB4 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}