{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RA2110-0JA15-1AP6","brand":"Siemens","brandSlug":"siemens","productSlug":"3RA2110-0JA15-1AP6","canonicalUrl":"https://aoctrl.com/siemens/3RA2110-0JA15-1AP6","factsUrl":"https://aoctrl.com/api/mcp/products/3RA2110-0JA15-1AP6","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RA2110-0JA15-1AP6 non-fused motor starter, size S00, direct starter, Class 10 thermal overload, 250 W at 400 V, 45 mm wide, DIN rail or screw mount.","salesMarkdown":"## SIRIUS 3RA2 direct starter — what ships in the box The 3RA2110-0JA15-1AP6: This is a Siemens SIRIUS 3RA2 non-fused motor starter, size S00, configured as a direct starter — meaning it combines a contactor and a thermal overload relay in a single, coordinated assembly for switching and protecting a motor load. The supplied contactor is a 3RT2015-1AP61, the link module is a 3RA1921-1DA00, and the circuit-breaker is a 3RV2011-0JA10 — all factory-matched, so you don't need to size the coordination yourself. Rated 250 W at 400 V (50 Hz) and 370 W at 500 V, 550 W at 690 V, with an operating frequency of 50 to 60 Hz. The overload release is thermal bimetallic (Class 10 trip), and the short-circuit trip is magnetic — typical for a compact motor starter protecting a small induction motor. ## Mounting and panel fit — DIN or screw Mounting position is vertical. Dimensions: 45 mm wide, 167.2 mm high, 97.1 mm deep. Clearances: 20 mm upward, 10 mm downward, 9 mm at the side — zero forward or backward. The size S00 footprint means it fits in compact distribution boards or small control panels. The terminal arrangement is standard for size S00; the screw terminals are captive and clearly marked. ## Active production — sourcing posture The supplied subcomponents (contactor, link module, circuit-breaker) are all standard catalog items, so if you already have those in stock you can also order them individually as spares.","metaTitle":"Siemens 3RA2110-0JA15-1AP6 SIRIUS Motor Starter, S00","metaDescription":"Siemens 3RA2110-0JA15-1AP6 SIRIUS non-fused motor starter, size S00, direct starter, Class 10 trip. Rated 250 W at 400 V. Active production, quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Motor Starters"],"specifications":{"Depth":"97.1 mm","Width":"45 mm","title":"3RA2110-0JA15-1AP6","Height":"167.2 mm","Upwards":"20 mm","Forwards":"0 mm","Backwards":"0 mm","Downwards":"10 mm","Trip Class":"CLASS 10","At The Side":"9 mm","Rated Value":"690 V","description":"Fuseless motor starter Direct start 600VAC Size S00 0.7-1A 220/240VAC 50/60HZ screw connection For screw mounting Or 35 mm rail-mounting Type of coordination 2 IQ = 150 KA Also full fills type Of coordination 1 1NO (contactor)","During Storage":"-50 ... +80 °C","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-55 ... +80 °C","Fastening Method":"Snap-mounted to DIN rail or screw-mounted with additional push-in lug","Mounting Position":"vertical","Product Brand Name":"SIRIUS","Type Of Assignment":"2","Degree Of Pollution":"3","Product Designation":"non-fused motor starter 3RA2","Size Of Load Feeder":"S00","at 400 V rated value":"250 W","at 50 Hz rated value":"187 ... 242 V","at 500 V rated value":"370 W","at 60 Hz rated value":"192 ... 264 V","at 690 V rated value":"550 W","Design Of The Product":"direct starter","at 575/600 V rated value":"0.5 hp","Of The Supplied Contactor":"3RT2015-1AP61","For Main Contacts Stranded":"0.5 ... 4 mm², 2x (0.75 ... 2.5 mm²)","Of The Supplied Link Module":"3RA1921-1DA00","Size Of The Circuit-Breaker":"S00","at AC-3 rated value maximum":"690 V","Design Of The Overload Release":"thermal (bimetallic)","Design Of The Switching Contact":"electromechanical","Operating Frequency Rated Value":"50 ... 60 Hz","at AWG cables for main contacts":"2x (20 ... 16), only for contactor 2x (18 ... 14), 2x 12","Design Of The Short-Circuit Trip":"magnetic","Of The Supplied Circuit-Breakers":"3RV2011-0JA10","Product Extension Auxiliary Switch":"Yes","Surge Voltage Resistance Rated Value":"6 kV","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","apparent holding power of magnet coil at AC":"4.8 VA","number of NC contacts for auxiliary contacts":"0","number of NO contacts for auxiliary contacts":"1","shock resistance according to IEC 60068-2-27":"6g / 11 ms","at 400 V according to IEC 60947-4-1 rated value":"153 000 A","at 500 V according to IEC 60947-4-1 rated value":"100 000 A","at 690 V according to IEC 60947-4-1 rated value":"100 000 A","operational current at AC-3 at 400 V rated value":"0.85 A","Type Of Electrical Connection For Main Current Circuit":"screw-type terminals","Inductive Power Factor With The Holding Power Of The Coil":"0.25","Mechanical Service Life (Switching Cycles) Of Contactor Typical":"30 000 000","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"13 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"0.7 ... 1 A","Connectable Conductor Cross-Section For Main Contacts Finely Stranded With Core End Processing":"0.5 ... 2.5 mm²"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/15f8e59b3faa89100f358c3e683d57e7.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=215035&mlfb=3RA2110-0JA15-1AP6"},"ai":{"faq":[{"question":"What are the power ratings for 3RA2110-0JA15-1AP6 at different voltages?","answer":"At 400 V it is rated 250 W, at 500 V 370 W, and at 690 V 550 W. At 575/600 V it is rated 0.5 hp. The coil voltage range is 187 to 242 V at 50 Hz and 192 to 264 V at 60 Hz."},{"question":"What subcomponents are supplied with the 3RA2110-0JA15-1AP6?","answer":"The assembly includes the 3RT2015-1AP61 contactor, the 3RA1921-1DA00 link module, and the 3RV2011-0JA10 circuit-breaker — all factory-coordinated for the S00 size."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RA2110-0JA15-1AP6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RA2110-0JA15-1AP6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}