{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RA2110-1ED15-1AP6","brand":"Siemens","brandSlug":"siemens","productSlug":"3RA2110-1ED15-1AP6","canonicalUrl":"https://aoctrl.com/siemens/3RA2110-1ED15-1AP6","factsUrl":"https://aoctrl.com/api/mcp/products/3RA2110-1ED15-1AP6","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RA2110-1ED15-1AP6 non-fused motor starter, direct starter, S00 size, CLASS 10, 690 V AC-3, thermal bimetallic overload, 45 mm width.","salesMarkdown":"## S00 direct starter with CLASS 10 trip curve The Siemens 3RA2110-1ED15-1AP6 is a non-fused motor starter from the SIRIUS family, size S00, configured as a direct starter. It ships as a pre-assembled unit: the contactor (3RT2015-1AP61), thermal overload relay, link module (3RA1921-1DA00), and busbar adapter (8US1251-5DS10) are all included — no separate ordering of subcomponents needed. The overload release is thermal bimetallic, so ambient temperature compensation is built in, but the unit should still be mounted vertical per the spec to avoid nuisance trips. ## Rated motor power across common line voltages At 400 V AC-3, the starter is rated for 1.5 kW motor output; at 480 V it draws 3.95 A, and at 600 V the current rating is 4 A. Horsepower ratings span from 0.13 hp at 110/120 V up to 3 hp at 575/600 V — covers most small three-phase motors in North American and European panels. Coil voltage is 187–242 V at 50 Hz and 192–264 V at 60 Hz, so it works on 208–240 V control circuits. ## Snap-on busbar mounting and panel clearance Mounting method is snap-on onto 60 mm busbar systems — no DIN rail required, which saves panel depth. The overall dimensions are 45 mm wide, 200 mm high, and 155.1 mm deep. Clearance requirements: 20 mm upward, 10 mm downward, 9 mm at the side, and zero forward/backward — tight stacking is possible.","metaTitle":"Siemens 3RA2110-1ED15-1AP6 SIRIUS Motor Starter, CLASS 10","metaDescription":"Siemens 3RA2110-1ED15-1AP6 SIRIUS non-fused motor starter, direct starter, S00 frame, CLASS 10 thermal overload. Active production, quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Motor Starters"],"specifications":{"Depth":"155.1 mm","Width":"45 mm","title":"3RA2110-1ED15-1AP6","Height":"200 mm","Upwards":"20 mm","Forwards":"0 mm","Backwards":"0 mm","Downwards":"10 mm","Trip Class":"CLASS 10","At The Side":"9 mm","Rated Value":"690 V","description":"Fuseless motor starter Direct start 600VAC Size S00 2.8-4A 220/240VAC 50/60HZ screw connection For snapping onto 60 mm busbar systems Type of coordination 2 IQ = 150 KA Also full fills type Of coordination 1 1NO (contactor)","During Storage":"-50 ... +80 °C","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-55 ... +80 °C","Fastening Method":"for snapping onto 60 mm busbar systems","Mounting Position":"vertical","Product Brand Name":"SIRIUS","Type Of Assignment":"2","Degree Of Pollution":"3","Product Designation":"non-fused motor starter 3RA2","Size Of Load Feeder":"S00","at 230 V rated value":"0.33 hp","at 400 V rated value":"1 500 W","at 480 V rated value":"3.95 A","at 50 Hz rated value":"187 ... 242 V","at 500 V rated value":"2 200 W","at 60 Hz rated value":"192 ... 264 V","at 600 V rated value":"4 A","Design Of The Product":"direct starter","at 110/120 V rated value":"0.13 hp","at 200/208 V rated value":"0.75 hp","at 220/230 V rated value":"0.75 hp","at 460/480 V rated value":"2 hp","at 575/600 V rated value":"3 hp","Of The Supplied Contactor":"3RT2015-1AP61","Of The Supplied Link Module":"3RA1921-1DA00","Size Of The Circuit-Breaker":"S00","at AC-3 rated value maximum":"690 V","Design Of The Overload Release":"thermal (bimetallic)","Of The Supplied Busbar Adapter":"8US1251-5DS10","Design Of The Switching Contact":"electromechanical","Operating Frequency Rated Value":"50 ... 60 Hz","Design Of The Short-Circuit Trip":"magnetic","Of The Supplied Circuit-Breakers":"3RV2011-1EA10","Product Extension Auxiliary Switch":"Yes","Surge Voltage Resistance Rated Value":"6 kV","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","apparent holding power of magnet coil at AC":"4.8 VA","number of NO contacts for auxiliary contacts":"1","shock resistance according to IEC 60068-2-27":"6g / 11 ms","at 400 V according to IEC 60947-4-1 rated value":"153 000 A","operational current at AC-3 at 400 V rated value":"3.6 A","Type Of Electrical Connection For Main Current Circuit":"screw-type terminals","Inductive Power Factor With The Holding Power Of The Coil":"0.25","Mechanical Service Life (Operating Cycles) Of Contactor Typical":"30 000 000","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"52 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Type Of Connectable Conductor Cross-Sections For Main Contacts Stranded":"0.5 ... 4 mm², 2x (0.75 ... 2.5 mm²)","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"2.8 ... 4 A","Connectable Conductor Cross-Section For Main Contacts Finely Stranded With Core End Processing":"0.5 ... 2.5 mm²"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/f9bf714ac92a14fc1f78c268dd150b03.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=434067&mlfb=3RA2110-1ED15-1AP6"},"ai":{"faq":[{"question":"Where can I buy 3RA2110-1ED15-1AP6 and how do I get a price?","answer":"This part is available to order through independent distribution. Submit an RFQ for current pricing and lead time — availability is confirmed at quote time."},{"question":"What is 3RA2110-1ED15-1AP6's listed depth (155.1 mm) on this Motor Starters line?","answer":"The depth is 155.1 mm, width is 45 mm, and height is 200 mm. Clearance needed: 20 mm above, 10 mm below, 9 mm at the side."},{"question":"What compliance documentation does Siemens provide for 3RA2110-1ED15-1AP6 (RoHS, REACH, UL, IEC)?","answer":"The starter carries a degree of pollution rating of 3 and is designed per IEC standards. Specific compliance declarations (RoHS, REACH, UL) are available from the manufacturer upon request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RA2110-1ED15-1AP6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RA2110-1ED15-1AP6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}